The sample hand collected and classified on site from BH 1 at a depth of 800 mm below the existing surface level returned a linear shrinkage result of 10.6%. The expected surface movement (Ys), due to seasonal moisture changes in the soil encountered, is as follows Ys Value = 27 mm Predicted Surface Movement Ys=<20 mm Ys => 40-< 60 mm Hl Ys => 60-<s 75 mm H2 Ys=>75 mm E Problem sites P Note: With a full depth clay profile the Ys value would increase to 30 mm. Note: Our assessment does not consider the effect of the presence of trees within or adjacent to the building site, nor the removal of trees prior to or after construction, nor the growth of trees too close to the footings. The proximity of trees and their effect on foundations should be considered when determining specific engineering assessments, and for foundation/footing design. Appendix B of AS 2870-2011 indicates that to reduce, but not eliminate, the possibility of damage to the footings, trees should be restricted to the following distance from the building (where rows or groups of trees are present the distance nominated below must be increased, and similarly the Ys Value listed above may need to be increased) : 75% of the mature tree height, for class “M” sites, 100% of the mature tree height, for class “H 1” sites, and 150% of the mature tree height, for class “E” sites. Note: This classification above has been derived from test work performed on the soil profile encountered on the day of our fieldwork. Any filling of the site or excavation into the soil profile, of 300mm may result in a different classification. Temporary Excavations. Where temporary excavations are performed for footing or services up to 600mm deep, natural soils may have minor or no stability problems, however deeper excavations have a possibility of collapse more readily and shoring of vertical excavation may be required. Where an existing excavation has been filled with uncontrolled fill, all locations above a line 30 degrees for sands and 45 degrees for clays above the horizontal may be unstable and may not support any structure — see attached critical depth line diagram. Existing Services. We were not informed of any existing service line excavations and no existing service line excavations were identified within or immediately adjacent to the proposed house site. Unearthed Geotechnical P/L. 4 Site Investigation Report 019-090
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment E - Secondary Dwelling (Exisitng Dwelling Plans from BA)Related documentApplication case desk ↗
About this file
- File size
- 8.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.