 Nationwide House Energy Rating Scheme* Certificate
  Certificate number: 0004058335-01 Certificate Date:                       21 Aug 2019            ★ Star rating:            6.4


 Building features

  Window type and performance value
  Window ID             Window type                                                                            U-value      SHGC
  ALM-002-01 A          ALM-002-01 A Aluminium B SG Clear                                                      6.7          0.70
  Window schedule
  Location        Window ID                    Window no.            Height (mm) Width (mm)              Orientation     Outdoor shade
  LAUNDRY         ALM-002-01 A                 n/a                   1400        900                     NW              No Shading
  Bedroom 2       ALM-002-01 A                 n/a                   1200        1800                    NW              No Shading
  W.C             ALM-002-01 A                 n/a                   1000        600                     NW              No Shading
  Unconditioned 3 ALM-002-01 A                 n/a                   1400        500                     NW              No Shading
  Bedroom 1       ALM-002-01 A                 n/a                   1200        1800                    NW              No Shading
  Kitchen/DINING ALM-002-01 A                  n/a                   600         2000                    NE              No Shading
  Kitchen/DINING ALM-002-01 A                  n/a                   1200        900                     NE              No Shading
  Kitchen/DINING ALM-002-01 A                  n/a                   2100        5400                    SE              No Shading
                  ALM-002-01 A                 n/a                   1800        2100                    SW              No Shading



  Roof window and skylight type and performance value
  ID                         Window type                                                                       U-value      SHGC
   None Present
  Roof window and skylight schedule
  Location              ID                      Roof                     Area (m²)      Orientation Outdoor shade Indoor
                                                window/skylight                                                   shade/diffuser
                                                no.
   None Present



  External wall type
  ID                    Wall type                        Insulation                                                      Wall wrap or foil
   EW-1                 Weatherboard Cavity Panel Direct Anti-glare foil with bulk no gap R2.7                           Yes
                        Fix
  External wall schedule
  Location                   ID                  Width (mm)          Height (mm)        Orientation           Fixed Shade     Eaves
                                                                                                                              (mm)
   LAUNDRY                   EW-1                 1995               2400                NW                    No              500
   LAUNDRY                   EW-1                 1995               2400                SE                    No              8800
   LAUNDRY                   EW-1                 2100               2400                SW                    No              500
   Bedroom 2                 EW-1                 3690               2400                NW                    No              500
   Bedroom 2                 EW-1                 1595               2400                SW                    No              2500
   W.C                       EW-1                 990                2400                NW                    No              500
   Unconditioned 3           EW-1                 2090               2400                NW                    No              500
   Bedroom 1                 EW-1                 3695               2400                NW                    No              500
   Bedroom 1                 EW-1                 3695               2400                NE                    No              2500
   Kitchen/DINING            EW-1                 3695               2550                NE                    No              2500
   Kitchen/DINING            EW-1                 7995               2550                SE                    No              3500
                             EW-1                 2495               2550                SE                    No              3500
                             EW-1                 3695               2550                SW                    No              2500

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments.        Page 2 of 5
  For more details see www.nathers.gov.au

Used in these records

About this file

File size
8.8 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment E - Secondary Dwelling (Exisitng Dwelling Plans from BA).pdf · 8.8 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.