Council archive · source document
Appendix A - Code Assessment Tables · MCU12/0133
From the archive Development Application Part 2 of 2, 2 - Forms, Owner's Consent, Charitable Organisation Status, 3 - Town Planning Report (Noosa FLC), Appendix A - Code Ass Tables.,Appendix B - Proposal Plans.Appendix C - Archit Design Statement. File date in the archive: 2012-09-04 09:38.
SPECIFIC OUTCOMES PROBABLE SOLUTIONS RESPONSE OR COMPLIANCE
including opaque security shutters) are used in windows which
are provided at ground level, to deter break and enters; and
c) hardy vandal proof materials and antigraffiti paint are used in
the construction of buildings, where appropriate.
O15 Lighting of appropriate intensities is provided to maximise S15.1 Lighting of appropriate intensities is provided which Complies. Lighting will be provided to the relevant standards.
safety. satisfies the requirements of Australian Standard AS1158: Public
Lighting Code, unless otherwise specified in this Code; and
S15.2 External lighting of a graduated intensity is provided which
starts at a lower level of brightness at the perimeter of the site
and rises to a greater intensity at the entrance to buildings, or at
the centre of the site; and
S15.3 Lighting is directed onto the site and away from
neighbouring properties; and
S15.4 Vandal-resistant lighting is used in public and publicly
accessible areas.
Mechanical plant and equipment and storage areas
O16 Mechanical plant and equipment (including air conditioning S16.1 Mechanical plant and equipment are— To Comply. Mechanical plant and equipment locations are not
equipment) and storage areas are designed and located to— a) located more than 2m from any property boundary; given; however, given the degree of vegetation retained and
a) avoid adverse visual impacts when viewed from the street and b) where located at ground level, screened by fencing 1.5m in landscaping proposed, particularly to the site boundaries,
adjoining properties; and height or dense vegetation of at least 1.5m in width incorporating mechanical plant and equipment are likely to be very well
b) be visually integrated with the building design. grouped trees and shrubs with maximum separation distance of screened from the street.
1m measured from the centre of the tree or scrub; and
c) are visually integrated into the line and plane of the building
and roof design and do not project beyond the height or width of
the building when viewed from the street and adjoining
properties.
14.32 Transport & access
O17 Premises have accessibility to public transport and cycling No solution provided Complies. Premises have access to public transport and
and walking is promoted. pedestrian/cycling paths. Bicycle facilities are provided.
O18 Cyclist facilities are provided to meet the needs of cyclists No solution provided Complies. Cyclist facilities are provided.
and encourage bicycle use by the users of the site
CHRISTIAN BROTHERS – FLEXIBLE LEARNING CENTRE, SUNSHINE BEACH 14
See the original