                     SPECIFIC OUTCOMES                                                   PROBABLE SOLUTIONS                                                  RESPONSE / COMPLIANCE
routes.
O5 The provision of landscaping is to a satisfactory standard        S5.1 Landscaping provided which allows adequate visibility for        Complies. While retention of native and landscaping has been
ensuring that it does not lead to opportunities for concealment      casual surveillance of public and semi-public spaces, including       maximised, it still maintains sightlines to public spaces,
and possible assault sites.                                          entrances and exits to sites and buildings, by:                       particularly approaches and entrances to the site and buildings.
                                                                     a) planting trees which have clean trunks to a height of at least
                                                                     1.8 m; and
                                                                     b) appropriately spacing shrubs at 1.2m horizontal centres, with
                                                                     a maximum height of 0.75m, to avoid clumping and to retain
                                                                     sightlines.
O6 Street trees and plantings in towns and villages, carparks        S6.1 Street trees and trees in carparking areas achieve a             Complies with Specific Outcome. The proposed landscaping
and other areas where potential conflicts with vehicles and          maximum of 900mm clear trunk height for a 2.0m high tree at           will retain the existing native vegetation of the site and relocate
pedestrians are evident, are planted so as to maximise vehicle       planting and are able to attain a clear trunk height of 1900mm on     where appropriate. This will be undertaken in accordance with
and pedestrian safety.                                               maturity;                                                             PSP3. No street trees are proposed.

                                                                     S6.2 All scrub planting to be a maximum height of 700mm from
                                                                     the road pavement (not top of kerb).
Services and utilities
O7 All landscaping works maintain adequate safe distance from        S7.1 Plant species used in landscaping adjacent to substations, Not Applicable. Site is not on or adjacent to an electricity
services and utilities including substations, overhead powerlines,   or adjacent to or on electricity transmission line easements, are transmission line easement or a substation.
power poles and transformers, street lamps, stormwater               less than 4m high at maturity and do not encroach within 3m of a
catchment pits, and underground services and utilities.              substation boundary;

                                                                     OR

                                                                     S7.2 For trees higher than 4m, trees are planted at a distance        Not Applicable. Landscaping will not be in proximity to an
                                                                     from any part of an electricity transmission line at least equal to   electricity transmission line.
                                                                     the expected height of the tree at maturity (see Figure 14-17;

                                                                     S7.3 For power lines that connect to a premises, the height of        Not Applicable. Electricity is provided as underground cables.
                                                                     plant species at maturity provides for a 2m clearance below the
                                                                     power line; (see Figure 14-18)

                                                                     S7.4 Trees and large scrubs are located a minimum of—a) 5m            To Comply. Landscaping will maintain this separation.
                                                                     from electricity poles and pillars;
                                                                     b) 4m from street lamps;
                                                                     c) 2m from stormwater catchment pits; and
                                                                     d) 2m from underground services and utilities;
                                                                     AND



CHRISTIAN BROTHERS – FLEXIBLE LEARNING CENTRE, SUNSHINE BEACH                                                                                                                                                    17

Used in these records

About this file

File size
532 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Appendix A - Code Assessment Tables.pdf · 532 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.