SPECIFIC OUTCOMES PROBABLE SOLUTIONS RESPONSE / COMPLIANCE
Firebreaks and fire access tracks
O11 Firebreaks or fire access tracks provide— S11.1 Firebreaks are provided by— Not Applicable. The proposal is not for lot reconfiguration.
a) adequate access for fire fighting and other emergency vehicles; a) a cleared road reserve not less than 20m wide located around
and the perimeter of the subdivision, between the created lots and
b) adequate width to minimise the risk of fire crossover. surrounding vegetated lands;
OR
b) fire access tracks (may be in the form of an access easement)
between the created lots and surrounding vegetated lands that—
i. are a minimum cleared width of 6m;
ii. have a formed pavement;
iii. have access at each end and in other locations where
necessary;
iv. have passing areas and turning areas;
v. have clearly identified access points for emergency vehicles;
and
vi. are located on public land or within access easements that are
granted in favour of Noosa Shire Council and the Queensland Fire
and Rescue Service40.
Road network
O12 Roads provide for the safe and effective evacuation of users S12.1 Culs-de-sacs or no-through roads are not used in the street Not Applicable. The proposal is not for lot reconfiguration.
of premises and access by Emergency services. network unless—
a) a perimeter road reserve with a minimum reserve width of 20m
and a formed width of not less than 6m is provided; or cul-de-sacs
or no-through roads are provided with fire trails or access
easements, capable of being navigated by conventional vehicles,
that link to through roads (see Figures 13.3 and 13.4);
AND
S12.2 Roads have a maximum grade of 1 in 8 (12:5%).
Lot design S13.1 Each lot includes a building envelope, identified on the plan Not Applicable. The proposal is not for lot reconfiguration.
O13 Lot design and building siting minimises bushfire hazard to of subdivision—
people and property having regard to slope, aspect, existing a) of sufficient size and dimensions to accommodate a dwelling
vegetation and adequate separation from hazardous vegetation. and ancillary buildings and use areas; and
b) for lots more than 2,500m—
i. conforming with the principles for house site number 1, 2 or 3
CHRISTIAN BROTHERS – FLEXIBLE LEARNING CENTRE, SUNSHINE BEACH 33
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix A - Code Assessment Tables.pdfRelated documentApplication case desk ↗
About this file
- File size
- 532 KB (small file)
- File type
No other editions are linked here.