Skip to the record
Beware of cheap imitations.

Council archive · source document

Appendix A - Code Assessment Tables · MCU12/0133

From the archive Development Application Part 2 of 2, 2 - Forms, Owner's Consent, Charitable Organisation Status, 3 - Town Planning Report (Noosa FLC), Appendix A - Code Ass Tables.,Appendix B - Proposal Plans.Appendix C - Archit Design Statement. File date in the archive: 2012-09-04 09:38.

of 44

Text shows just the words. Original shows the document exactly as it was published.

Driveways and Carparking Code

Driveways
                     SPECIFIC OUTCOMES                                                PROBABLE SOLUTIONS                                                RESPONSE / COMPLIANCE
General
O1 Vehicular access does not adversely impact on safety,           S1.1 Vehicular access is located and designed in accordance        Complies/To Comply. Only one footpath crossing is provided.
capacity and operations of the existing or planned road network,   with AUSTROADS Guide to Traffic Engineering Practice               Vehicular access will be subject to a subsequent operational
the proposed driveway, cycleways or pedestrian pathway             requirements for sight distance and Section 3 of AS2890.1          work application and will comply with these standards.
systems.                                                           Parking Facilities;
                                                                   AND
                                                                   S1.2 Only one footpath crossing is provided24;
                                                                   AND
                                                                   S1.3 Driveways, other than within any setback have a maximum
                                                                   grade in accordance with Section 3 of AS/NZS 2890.1
O2 Driveways and crossovers—                                       S2.1 Design of the driveway across the footpath is in accordance   To Comply. Driveway will be subject to a subsequent
a) are suitable and safe for their intended use; and               with Council’s Standard Drawings 9002 or 9005 as appropriate       operational work application and will comply with these
b) match Council infrastructure.                                   for the particular type of development as annotated on the         standards.
                                                                   drawings;
                                                                   AND
                                                                   S2.2 Driveways are designed and constructed in accordance
                                                                   with Council Standard Drawings 9014, 9019, 9020, 9021, as
                                                                   appropriate for the particular type of development as annotated
                                                                   on the drawings;
                                                                   AND
                                                                   S2.3 The change in grades in the driveways and ramps is in
                                                                   accordance with Section 3 of AS2890.1 Parking Facilities.
O3 In commercial zoned areas, the number of driveways across       S3.1 Design of multi-tenanted developments in commercial           Not Applicable. Site is not in a commercial zoned area.
pedestrian footpaths is minimised.                                 zoned areas include shared driveways and parking areas;
                                                                   AND
                                                                   S3.2 Driveways are located so they abut existing driveways of
                                                                   adjoining development where practicable and reciprocal
                                                                   easements are created to reduce the sealed driveway width.
O4 Vehicular access does not adversely impact on the capacity,     S4.1 Footpath and kerb crossings are located clear of existing     Complies/Complies with Specific Outcomes. Proposed
operations and maintenance of the existing infrastructure;         stormwater inlet structures, water and sewerage infrastructure     vehicular access is clear of existing utility infrastructure. As the
                                                                   fittings, any other exiting utility infrastructure, existing       site is vegetated, the vehicular access will impact on the existing
AND                                                                landscaping and vegetation.                                        native vegetation; however, cleared vegetation will be used in
                                                                                                                                      landscaping across the site.
O5 Vehicular access does not adversely impact on the integrity     S5.1 No solution provided
of existing landscaping or native vegetation.

CHRISTIAN BROTHERS – FLEXIBLE LEARNING CENTRE, SUNSHINE BEACH                                                                                                                                           35

Used in these records

About this file

File size
532 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Appendix A - Code Assessment Tables.pdf · 532 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.