Existing Services Code

                   SPECIFIC OUTCOMES                                                PROBABLE SOLUTIONS                                                    RESPONSE / COMPLIANCE
Setbacks and easements                                                                                                                  Complies. The proposal will avoid interference with infrastructure
O1 Development near a sewer, water main, stormwater drain,      S1.1 The footing of any structure or building is located clear of       services.
overland flow path or associated structure does not—            the zone of influence but no closer than 1.5m (measured
a) adversely affect the function of the service;                horizontally) from infrastructure including sewers, water mains
b) place an additional load on the service; and                 and stormwater structures;
c) unduly increase future maintenance costs.                    AND
                                                                S1.2 No building or structure overhangs the zone of influence;
                                                                AND
                                                                S1.3 Finished surface levels maintain a minimum of 600mm of
                                                                cover, but no greater than 3m of cover to the underground
                                                                infrastructure;
                                                                AND
                                                                S1.4 If the existing surface level is altered, surface level services
                                                                including manholes and inspection points are altered to match
                                                                the new surface level;
                                                                AND
                                                                S1.5 Alterations are constructed in accordance with Sections 3,
                                                                4 and 5 of PSP6 –Engineering Design Standards — Water and
                                                                Sewerage and Section 4 of PSP5 –Engineering Design
                                                                Standards – Roads, Drainage and Earthworks;
                                                                OR
                                                                S1.6 Existing services are relocated and the design and
                                                                construction of the relocated services is in accordance Sections
                                                                3, 4 and 5 of PSP6 –Engineering Design Standards — Water
                                                                and Sewerage and Section 4 of PSP5 – Engineering Design
                                                                Standards – Roads, Drainage and Earthworks.
O2 Maintenance access is provided to all sewers, water mains,   S2.1 A registered easement in favour of Council is created over         Complies with Specific Outcome. Maintenance access for
stormwater drains, overland flow paths and associated           all underground infrastructure located in private property;             Council to the wastewater manhole at the lot’s south-western
structures.                                                     AND                                                                     corner will be maintained.
                                                                S2.2 The width of the easement is the greater of 3m or the width
                                                                of the zone of influence;
                                                                AND
                                                                S2.3 The easement is centred over the centreline of the
                                                                infrastructure.




CHRISTIAN BROTHERS – FLEXIBLE LEARNING CENTRE, SUNSHINE BEACH                                                                                                                                            40

Used in these records

About this file

File size
532 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Appendix A - Code Assessment Tables.pdf · 532 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.