Council archive · source document
Appendix A - Code Assessment Tables · MCU12/0133
From the archive Development Application Part 2 of 2, 2 - Forms, Owner's Consent, Charitable Organisation Status, 3 - Town Planning Report (Noosa FLC), Appendix A - Code Ass Tables.,Appendix B - Proposal Plans.Appendix C - Archit Design Statement. File date in the archive: 2012-09-04 09:38.
SPECIFIC OUTCOMES PROBABLE SOLUTIONS RESPONSE / COMPLIANCE c) for the Semi-Attached Housing Zone does not exceed 40%; d) for the Attached Housing Zone does not exceed— i in Sunshine Beach–35%; or ii otherwise–40%; or e) for the Visitor Mixed Use Zone does not exceed 35% f) for the Community Services Zone does not exceed 50% O8 For Multiple Housing Type 2 buildings have a maximum plot No solution provided Not Applicable. Proposal is not for Multiple Housing. ratio of— b) 0.6:1 if in the Attached Housing Zone located in Sunshine Beach or c) 0.45:1 otherwise. O9 For Multiple housing Type 3 or 4, Visitor accommodation No solution provided Not Applicable. Proposal is not for Multiple Housing. Type 4 or the accommodation unit component of an Entertainment and dining business Type 3 (hotel)—the maximum gross floor area is equivalent to the maximum allowable population density in persons multiplied by 40m2, provided that Lots 75-77 on P9311 Heron Street, Peregian Beach, have a maximum gross floor area of 1,200m2. O10 For the Neighbourhood Centre Zone the maximum plot ratio No solution provided Not Applicable. Proposal is not in the Neighbourhood Centre is as follows— Zone. a) 0.8:1 for site areas up to and including 2000m2; and b) 0:3:1 for that area of a site in excess of 2,000m2. Flooding and drainage O11 Buildings and other works are designed and sited to— S11.1 For new buildings or structures or additions of more than Complies. Site is not mapped in a Flood Hazard area, is not a) provide flood free access to premises and flood free habitable 50m2 gross floor area to an existing building or structure, floor within proximity to a watercourse and is not known to flood. areas; levels for habitable rooms are— b) allow only minor, short term and infrequent flooding of non- a) for areas where minimum floor levels are available—not less habitable areas; ‘ than the specified level; c) ensure carparking areas can be adequately drained; b) for areas where flood modelling is available—a minimum of d) ensure drainage does not adversely impact upon other 500mm above the modelled flood level; and premises; and c) for areas where flood modelling is not available, a minimum of e) ensure filling or excavation does not adversely impact upon 500mm above the highest known flood level; other premises by— AND i. causing ponding on the site or nearby land; ii. increasing flooding, which adversely affects the safety or use S11.2 Where Council infrastructure is available— Complies. Runoff from the site will be directed to the drainage of any land upstream and downstream; a) any drainage (for buildings and land) flows to that system of Girraween Court. Annual surface runoff from the site CHRISTIAN BROTHERS – FLEXIBLE LEARNING CENTRE, SUNSHINE BEACH 4
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix A - Code Assessment Tables.pdfRelated documentApplication case desk ↗
About this file
- File size
- 532 KB (small file)
- File type
No other editions are linked here.