Attachment A -Approved Plans
The original of this document is very large (14.2 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Original PDF page 11, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn - NOTES:
unit 5, the hastings, noosa parade
lot 5 on GTP1154
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN
APPROVED PLAN DOMESTIC BUILDING CODE.
51983.3225.10 2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010
RESIDENTIAL TIMBER FRAMING MANUAL.
NOOSA COUNCIL 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM
1 AUGUST 2017 JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
UPPER FLOOR TOP PLATE SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH
UPPER FLOOR JOINERY AS 1684.2 2010
7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE
OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH
MANUFACTURERS SPECIFICATIONS.
2400
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS
UPPER FLOOR AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS
FIRST FLOOR TOP PLATE 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO
RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED
FIRST FLOOR JOINERY LINE 11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN
STANDARDS RELATING TO HIS OR HER OWN WORK
2400 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000
FIRST FLOOR DOMESTIC SMOKE ALARMS:
GROUND FLOOR TOP PLATE 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED WITH
GROUND FLOOR JOINERY LINE PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE
awning window SAFETY LEGISLATION AMENDMENT REGULATION 2016
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE WITH AS
2400
1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL AND INTERCOM
SYSTEMS.
GROUND FLOOR 3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD WIRED
100
(EXISTING DWELLINGS ONLY) THAT CANNOT BE
PAD LEVEL
REMOVED FROM DEVICE
vertical timber cladding alike existing
elevation A elevation B NOTE: SMOKE ALARMS TO BE INSTALLED IN ALL HALLWAYS AND BEDROOMS
TO EXISTING RESIDENCE
upper floor top plate
upper floor joinery
2400
upper floor bed
first floor top plate
first floor joinery
2400
first floor kit
ground floor top plate
ground floor joinery
90mm timber framing+
2300
vj lined and painted
2400
cladding over alike existing between joists, nominal height
to u/side of lining 2400
ground floor
elevations
slab and footings as required
elevation C elevation D Section 1
PROPOSED: CLIENT: PAUL TEYCHENNE BUILDER: MICK GARDNER MANDY'S DESIGN & DRAFTING SHEET: 4 of 4 DATE: ISSUE NO:
BUILD IN GROUND+ALTERATIONS PH: 0414 697 882 PH: 0403 481 474 SCALE: 1:100 JULY 2017 A
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
Document Set ID: 21304948
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
Version: 2, Version Date: 25/11/2020