2 David Low Way - Attachment 2 - Ecological and Bushfire Assessment Report 9-8-17
Attached to the e-mail Reconfiguration of a Lot (1 lot into 6) - RAL17/0501.
The original of this document is very large (10.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Original PDF page 84, section 1. The text section number identifies this passage in the reader.
Natural Hazards (Bushfire) Overlay Code Assessment
Specific Outcomes Probable solutions Response
iii) 10m from any retained which would prevent a fire front
vegetation strips or small areas from directly impacting on the Site.
of vegetation; and
iv) so that the elements of the
development least susceptible to
fire are sited closest to the
bushfire hazard;
b) on lots 2,500m2 or less - to
maximise setbacks from hazardous
vegetation
13.35 Water supply for fire fighting
O8 An adequate and accessible water S8.1 For premises not in a water Complies
supply is provided for fire fighting service area— each lot has an The development would be serviced
purposes can be accessed by fire accessible dam, swimming pool or by reticulated water supply with
fighting appliances.. water tank accessible by the fire adequate provision being made for fie
brigade that contains at least 5000 fighting purposes.
litres of water.
13.36 Vehicle access and fire trails
Firebreaks and fire access tracks
O9 Firebreaks or fire access tracks S9.1 Firebreaks are provided by— Complies
provide— a) a cleared road reserve not less David Low Way provides an
a) adequate access for fire fighting and than 20m wide located around the appropriate fire break and access trail
other emergency vehicles; and perimeter of the development; separating the Site from adjacent
b) adequate width to minimise the risk OR Medium to High bushfire hazard areas
of fire crossover. located to the west of David Low Way.
b) fire access tracks between the
development and surrounding The internal Site access also provides
vegetated lands that— appropriate access for fire
suppression and building protection if
i. are a minimum cleared width of required.
6m;
ii. have a maximum grade of 1 in 8
(12.5%) ;
iii. have a formed pavement;
iv. have access at each end and in
other locations where necessary;
v. have passing areas and turning
areas;
vi. have clearly identified access
points for emergency vehicles; and
vii. are located on public land or
within access easements that are
granted in favour of the Noosa
Council and the Queensland Fire
and Rescue Service.
13.37 Reconfiguring a Lot
General
O10 The safety of people and property S10.1 The proposed lots are not Complies
are maintained by located on land that is subject to The defined building envelopes within
a) Locating house site areas and other Bushfire Hazard; the proposed residential lots are
sensitive uses on that part of the land OR located in a low hazard area given that
least affected by the bushfire hazard; S10.2 The proposed lots are sited on they are:
and land determined as low bushfire risk located at least 60m from identified
b) fire mitigation methods are used that by a site specific bushfire hazard bushfire hazard areas to the west
are adequate for the Potential Bushfire assessment. of David Low Way; and
I:\WE Jobs 2017\WE17035 - Castaways Beach\wp\Appendix F - Natural Hazards Code assessment.docx