Original source · versioned page text
Judgement - 11C Church Street
PA106 UNIT 6 - 3 BED
UNIT 6 GARAGE 34.2 m²
2 UNIT 6 INTERNAL 124.8 m²
UNIT 6 PATIO 11.9 m²
LANDSCAPING R1 LANDSCAPING LANDSCAPING UNIT 6 PORCH 2.2 m²
R1
UNIT 6 REAR PORCH 3.6 m²
TOTAL FLOOR AREA 176.7 m²
3 PA106
UNIT 7 - 2 BED
PA106 6
UNIT 7 GARAGE 18.0 m²
F3
UNIT 7 INTERNAL 86.7 m²
FL 92.50 m 6 FL 92.68 m
UNIT 7 PATIO 10.1 m²
9 8 7 PA106 7 F1
UNIT 7 PORCH
UNIT 7 REAR PORCH
2.2 m²
3.6 m²
TOTAL FLOOR AREA 120.6 m²
FL 94.40 m
FL 93.65 m POS 43m²
SCREENED SCREENED
SERVICE SERVICE UNIT 8 - 3 BED
PA106 5
UNIT 8 GARAGE 34.2 m²
POS 25m² F3
2500
F1 UNIT 8 INTERNAL 98.8 m²
F1 R1
F1 UNIT 8 PATIO 9.4 m²
R1
F3 SERVICE F1 UNIT 8 PORCH 2.6 m²
SCREENED
SCREENED
UNIT 8 REAR PATIO 1.6 m²
SERVICE
TOTAL FLOOR AREA 146.5 m²
POS 40m² POS 42m²
2570
R1
F3
F1 F1 UNIT 9 - 3 BED
4
UNIT 9 GARAGE 34.2 m²
1 FLOOR PLAN UNITS 6-9 UNIT 9 INTERNAL 98.8 m²
99.45 m
PA106 1 : 200 8 9 UNIT 9 PATIO
UNIT 9 PORCH
9.4 m²
2.6 m²
6 97.53 m
7 CB1
UNIT 9 REAR PATIO
TOTAL FLOOR AREA
1.6 m²
146.5 m²
CB2 CB1
CB1
GD1
GD1 94.40 m
93.65 m W2
W2 GD1 GD1
92.68 m 92.50 m
92 NORTH ELEVATION 99.45 m
1 : 200
8 7
97.53 m 6
CB2
CB1
94.40 m
93.65 m W2 W3
92.50 m
99.45 m 8
4 SOUTH ELEVATION W3
1 : 200
9 CB1
CB2 W1 97.53 m
7 W3
W1
CB2
99.45 m
CB2
97.53 m
6 W3 CB1
CB2
CB1 CB1
W4 W4
W3
W2 92.48 m
W2 94.40 m
92.68 m
6 UNIT 7 WEST ELAVATION 7 UNIT 8 EAST ELEVATION
3 UNIT
1 : 200
6 EAST ELEVATION 5 UNIT
1 : 200
9 WEST ELAVATION 1 : 200 1 : 200
Address: No. Issue Details Date
Client: Drawing Name:
BUILDING DESIGN 27 RFI REDESIGN 07-09-2022
AUSTRALIA WIDE Zaccale Pty Ltd 11C Church Street, Pomona QLD 4568 28 Revision 28 07-08-2022 FLOOR PLANS AND ELEVATIONS
RESIDENTIAL
COMMERCIAL
31
32
REDESIGN
SANDSTONE RETAINING
30-09-2022
04-10-2022
UNITS 6-9
RENOVATIONS 33 DRAIN REFERENCE 05-10-2022
ACCESSIBLE Project number 11808
PH. 0405 097 553
Project: Property Details: 34 SANDSTONE RETAINING 05-10-2022
35 ENGINEERING REDESIGN 22-11-2022
[email protected]
www.alldd.com.au Residential Multi Unit Development LOT 4 SP301620 7517m² 38 REDESIGN 18-05-2023
Current Issue Date 25-07-2023
VBA DP-AD 37989 40 FENCING 19-05-2023 Scale (A3) 1 : 200
QBCC 1084590 42 AMENDMENTS 12-06-2023
BDAA 6779 Drawing no. PA106
Status: REDESIGN
THIS DRAWING IS THE COPYRIGHT AND PROPOERTY OF ALL DESIGN AND
43 CONDITIONS REVIEW 25-07-2023
DRAFTING. IT IS NOT TO BE COPIED, RETAINED OR USED FOR ANOTHER PURPOSE.
19
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file