Proposed Plan
Attached to the e-mail Operational Works Application OPW19/0193 - DA Form 1- Cover Letter - Proposed Plan - 91 Ewarts Rd COORAN.
The original of this document is very large (12.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn 8.5m
BUILD
ING
ENVE
LOP E
ENGINEER DESIGNED ROOF
TRUSSES AT 900 CRS MAX
COLORBOND FASCIA
AND GUTTER
UPPER CEILING
198.710
460
2760
2760
N.G.L
. PORTICO COCHERE ENTRY LIVING VERANDAH
2100
2100
2585
FLOOR PLAN
R.L.195.950
FLOOR FRAMING AND
BRACING AS DESIGNED
WATER PROOFING NOTES:
1.0Damp course under yellow tongue flooring on all deck areas.
2.0Cladding to cover floor joists on non deck areas.
3.0Decking flashing on ALL deck areas in all directions
4.0Window flashing on all windows and doors except where eave is hard on the window or door
4.1Flashing is be 25mm past the edge of the window.
4.2Larger flashing is required for 3+ door track
5.0Flashing over wall penetrations such as beams and joists etc
5.2Flashing to be installed 25mm past the edge A-04-01 - SECTION A-A
5.3Damp course flashing around penetration similar to a window edge flashing 1
5.4Seal beam to the claddings 1 : 50
5.5Install cover strips around the penetration and seal under the cover strips FOOTINGS TO ENGINEERS
6.0Use stops not cover strips on all corners DESIGNED
6.1Seal cladding to cover strips
7.0Damp course on all corners and over deck flashing
8.0Sisalation over damp course
9.0Horizontal joins on cladding to have over under flashing and cover strips.
10.0Timber joinery (Front doors and timber windows)
10.1Flashing to be installed 25mm past the edge
10.2Install damp course flashing
10.2.1Similar to a window edge flashing
10.3Seal to the claddings
10.4Install cover strips and seal under the cover strips
CONSTRUCTION
SCALE: No. Description Drawn Date
PHONE (07) 5476 8690 Martens Building Design CLIENT:
A. & S. Leontakianakos
SHEET:
1 PRELIMINARY KURT 04/04/19
1 : 50@ A3 FAX (07) 5476 9380 0432 224 604 A-04-
04-01 SECTION A-
A- A
TRU BUILT
9 WORKING DRAWINGS KURT 07/07/19 MOBILE 0418 986595
DATE: [email protected] ADDRESS: REVISION: WIND RATING FIRE RATING
07/07/19 PO BOX 1244 ABN: 20 218 687 996 LOT 61 #91 EWARTS ROAD, 9 N5 BA L 19
BUDERIM 4556
DESIGNED:
LIC NO. 729650
QBSA: 126 4589 COORAN, QLD,
Signed:___________________ TRU BUILT JOB NO.: MBD NO.:
Rod Soppe R & V DEVELOPMENTS PTY. LTD. 1008 J 1907
Kurtis Martens / Owner