MCU15/0045 - Approved Plans
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn A B C D E F
2,500 2,250 2,500 6,000 12,250
6,000 1,250 8,750 1,250 2,250
Colorbond Stainless Steel roofing to roof below, Timber screen over to detail, 100 x 50 HWD battens, A
80 fall clear polycarbonate lining above - to interior only 301
RL. 32,30
Parapet wall
dp
1 1
150 Half Round Gutter, Colorbond Timber screen over to detail, 100x50
Stainless Steel line of window below HWD battens
Timber screen to detail, 100x50 HWD
3,000
3,000
battens on powdercoated aluminium
Roofing 80, Colorbond Ultra Range
line of window below
frame
Surfmist, class 5 screws Roofing 10, Trimdek
FALL FALL
2 2
3,000
3,000
3 Parapet wall
dp 3
Custom Vergola gutter over flat
roof below
flat roof over
Vergola over First Floor Deck, Colorbond Ultra Range
3,000
3,000
Colorbond Stainless Steel roofing to roof below, Roofing 80, Colorbond Ultra Range Powdercoated Aluminium Blade Awning
80 fall Surfmist, class 5 screws
Timber screen to detail, 100x50 HWD battens on
powdercoated aluminium frame FALL
Consult architect on dp location & detail. RL. 32,49
Allow for 90mmØ colorbond 150 Half Round Gutter, Colorbond Ultra Range
4 4
1,250
1,250
Note: Solar panels indicative only. Solar Note: Solar panels indicative only. Solar Note: Solar panels indicative only. Solar
panels by others panels by others panels by others
FLUE
6,000
3,500
3,500
6,000
line of window below
Roofing 80, Colorbond Ultra Range Roofing 80, Colorbond Ultra Range
Surfmist, class 5 screws Surfmist, class 5 screws
FALL FALL
line of window below line of window below
1,250
1,250
5 5
RL. 33,37
Colorbond Stainless Steel roofing to roof below, Line of clerestory window
80 fall below A
301 APPROVED PLANS
MCU15/0045
Boundary fence below shown as dashed
NOOSA COUNCIL
16 JUNE 2015
A B C D E F
ISSUE AMENDMENTS DRAWN JCH
- COPYRIGHT - These drawings to be A Working Drawings 10/04/2015
CLIENT Carter
used only with Architects written 23/04/2015 DATE 08/05/2015
consent. 28/04/2015
SCALE 1:100 (A3 Paper)
08/05/2015
- DO NOT SCALE OFF DRAWINGS. PROJECT NEW Residence
LOT 17 Noosa Dunes, Castaways Beach NO. 1503
- Refer any discrepancies to Architect.
ROBINSON
ROBINSON ARCHITECTS
67 MEMORIAL DRIVE,
- Verify all dimensions on site.
DRAWING WD104 - Roof Plan
EUMUNDI QLD 4562
A RC HIT ECT S Ph. (07) 5442 8566
www.robinsonarchitects.com.au