Skip to the record
Noosa's #1 Council Tracker.

Original source · versioned page text

Proposed Plans

of 8

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
                                                 WEYBA
                                                           ROAD

                                                                   Proposed
                                                                   Insulated
                                                                   Roof




                          FENCE
                                                                                       NOT TO SCALE

                            ARY




                                              CE
                                            EN
                       BOUND




                                             F
                                          RY
                                       DA
                                    UN
                                  BO




                                                                                    WEYBA
                                                                                             ROAD
                                                                                                                        Revision
               FENCE




                                                                                                                        ISSUE A 25/02/21 for CERTIFICATION
                 ARY
            BOUND




 Existing
  Resort
Buildings                                                                                                               Replacement Shade Structure

                                                   7,300                                                                2021-08
                 Approximately 32m to Boundary                                                                          South Pacific Resort, 179 Weyba Rd
                                                           3,400




                                                                                                                        Noosaville, QLD, 4566




                                                                                                                   CE
                                                                                                                        Lot 2 on SP163789




                                                                                                              EN
                                                                                                                        Marcel Blas




                                                                                                               F
                                                                                                            RY
                                                                                                         DA
                                                                                                                        Drawing Title:




                                                                                                       UN
                                                                                                                        Site Plan

                                                                                                     BO
                                                                                                                        Scale: As Shown     Status: SD
7.3x3.4m Proposed Insulated Patio                                        Existing Resort Buildings                      Drawing Number:     Issue:
    Replacing existing shade sails
                                                                                                                        SD01                         A
   Approx 32m from side boundary
Log in to download the original file

Proposed Plans.pdf · 1.2 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 7 pages

Page 2

AUTHORISED DEALER

 

PLEASE CHECK THAT ALL ORDER DETAILS ARE CORRECT.
YOUR ORDER IS NOW BEING PROCESSED BASED ON THE FOLLOWING DETAILS.

JOB DETAILS CUSTOMER DETAILS
JOB REFERENCE: Flat CLIENT NAME: Marcel Bias
DESIGN NUMBER: 0Q732844 PHONE NUMBER: 0412564455

SALES PERSON: Mr Dan Homewood ACCOUNT CODE: SEQPATIO

DELIVERY DETAILS

DELIVERY INSTRUCTIONS: 179 Weyba Road
Noosaville

4566
ADDITIONAL INSTRUCTIONS:

Unit
Design Type Flat Attached Type 1A

Site Detail

WindSpeed N2

  

Is

Components

140 Column Wraps No
Back Channel Details Cooldek Back Channel CGI (50mm)

Beam Type 150 Outback Beam
Bolted Columns No

Column Size 68 Outback Column
Downpipe Type Downpipe 90mm PVC
Gutter Type C Square Gutter Slotted

 

Dimensions

Deck Overhang 0

Height 2900mm
Length 7300mm
Width 3400mm
Engineering

 

Column Spacing 6467mm

Roof Details

Deck Type Cooldek CGI 50mm

Cooldek Options

 

 

 

 

 

 

 

 

 

Cooldek Cutback 65mm
: : Cooldek Underside Type Smooth
Footing Details Use BAL Flashings No
450x450x750, 75mm corbel
Footing Type In Ground
Use Welded Base Plates No Colours
Column Colour Alpine ™
: Cooldek Bottom Colour Off White
Reinforcement Components Cooldek Cutback Colour Off White
Adjustable Rafter Strengthening Bracket 7 Cooldek Side Capping Colour Off White
Reinforcing Channel 14 Downpipe Colour Off White
External Beam Colour Alpine ™
Gutter Colour Off White
Roof Colour Off White
Wall
1100
Fascia
Loy i i i i i i
i i as! i i i i
i i 1 i i i i 3400
ji } H } i } at
C u
DP|
7300

 

 

CUSTOMER SIGNATURE:

DATE: 16/02/2021

 

 

Page 3

era i)

9)
a
f
=)

4
a
=|
4
a
)
ry
ry
tt
z
°
4
3
<

 

0Q732844
16/02/2021

Design Number

Date

Site Plan
Job Reference
Sales Person
Client Name

179 Weyba Road

Noosaville

Site Address

Flat

Mr Dan Homewood

Marcel Bias

 

 

Wall

|-
Fascia

3400

 

 

 

 

 

 

 

 

 

7300

 

 

Page 4

era td

UIBACK.

NOY

 

< Design Number 0Q732844
Front Elevation Date 16/02/2021
Job Reference Flat Site Address 179 Weyba Road
Sales Person Mr Dan Homewood Noosaville

Client Name Marcel Bias

 

 

 

 

Page 5

era td

UIBACK.

NOY

 

< Design Number 0Q732844
Rear Elevation Date 16/02/2021
Job Reference Flat Site Address 179 Weyba Road
Sales Person Mr Dan Homewood Noosaville

Client Name Marcel Bias

 

 

 

 

Page 6

era i)

UIBACK.

NOY

 

< Design Number 0Q732844
LeftElevation 0 Date 16/02/2021
Job Reference Flat Site Address 179 Weyba Road
Sales Person Mr Dan Homewood Noosaville

Client Name Marcel Bias

 

 

 

Page 7

era i)

UIBACK.

NOY

 

. < Design Number 0Q732844
Right Elevation Date 16/02/2021
Job Reference Flat Site Address 179 Weyba Road
Sales Person Mr Dan Homewood Noosaville

Client Name Marcel Bias

 

 

 

 

Page 8

era td

UIBACK.

NOY

 

. Design Number 0Q732844
Current View Date 16/02/2021
Job Reference Flat Site Address 179 Weyba Road
Sales Person Mr Dan Homewood Noosaville

Client Name Marcel Bias

 

 

 

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.