Minor Change Existing Approval - MCU26 0012 01 & OPW26 0034 01 (As Published) · MCU26/0012.01
Site Access and Driveways
19. An access driveway must be provided from the existing driveway crossover from Lukes Road
to all parking and manoeuvring areas of the development. The works must be undertaken in
accordance with SCG Consulting’s Driveway Levels Plan Part 1 and Part 2 (OW4.1 & OW4.2,
Rev. A) dated 17 July 2026 and the conditions of this Decision Notice.
Stormwater Drainage
20. Stormwater runoff from the development must be disposed of on-site without causing scour
or damage to the subject site or any adjoining property.
Easements
21. Unless otherwise agreed in writing by the relevant service provider, any public or third party
infrastructure located on the subject site must be placed within an easement registered
against the title of the property.
22. All easements must be designed in accordance with the planning scheme and granted at no
cost to the Grantee. Where the Grantee is Council or a service authority, the easement
documentation must be in accordance with the Grantee’s standard easement terms. Draft
easement documentation must be submitted to Council for endorsement.
23. All works must be kept clear of any existing or proposed easements on the subject land,
unless agreed otherwise in writing by the Grantee.
Geotechnical Stability
24. All works must be carried out in accordance with the recommendations contained in Slope
Stability Assessment (26020-001-Rev0), prepared by tectonic and dated 13 February 2026,
listed within this Decision Notice.
Earthworks and Retaining Walls
25. All earthworks and associated batters/retaining structures, both above and below ground
level, both temporary and permanent, must be undertaken in accordance with the conditions
of this Decision Notice, be generally in accordance with SCG Consulting’s Earthworks Plan
Part 1 and Part 2 (OW3.1 & OW3.2, Rev. A) dated 17 July 2026 and Earthworks Sections
(OW3.3, Rev. A & OW3.4) dated July 2026 and contained entirely within the subject site
unless written permission from the respective landowner(s) is provided to Council.
26. All retaining walls must be designed and constructed in accordance with the planning scheme
and must be certified by an RPEQ where exceeding 1.0m in height. All retaining walls that
are publicly accessible and exceed 1.0m in height must be fitted with a commercial grade
safety fence.
Page 4 of 11
Document Set ID: 25192949
Version: 4, Version Date: 29/09/2026
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Minor Change Existing Approval - MCU26 0012 01 & OPW26 0034 01 (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 185 KB (small file)
- File type
No other editions are linked here.