        STAIR AND BALUSTRADES: ALL BALUSTRADES AND HANDRAILS TO BE
        1000 MIN ABOVE FINISHED FLOOR LEVEL, 865MM MIN ABOVE STAIR
        NOSINGS AND HAVE NO OPENINGS GREATER THAN 125MM, IN
        ACCORDANCE WITH NCC VOL 2 2019 PART 3.9.2. FLOORS OVER 4M
        MUST NOT FACILITATE CLIMBING BETWEEN 150MM AND 760MM FOR
                                                                                             WET AREAS: ALL WET AREAS ARE TO BE WATERPROOFED
                                                                                             THROUGHOUT WITH A PROPRIETARY WATERPROOFING SYSTEM
                                                                                             INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS
                                                                                             RECOMMENDATIONS AND NCC REQUIREMENTS, WITH JUNCTIONS
                                                                                             BETWEEN WALL AND FLOOR FLASHED TO PREVENT MOISTURE
                                                                                                                                                                                                   ARTICULATION JOINTS: PROVIDE ARTICULATION JOINTS TO COMPLY
                                                                                                                                                                                                   WITH ENGINEERS DESIGN AND "CEMENT AND CONCRETE
                                                                                                                                                                                                   ASSOCIATION CONSTRUCTION NOTE TN9".
                                                                                                                                                                                                   POOL: CONTRACTOR TO CONFIRM HEIGHTS/DEPTHS/STEPS AND
                                                                                                                                                                                                   PLUMBING/ELECTRICAL REQUIREMENTS AND LOCATIONS PRIOR TO
                                                                                                                                                                                                                                                                                                              010.02
        BALUSTRADES TO STAIRS. MINIMUM STAIR CLEARANCE 2.0M MEASURE                          PENETRATION INTO WALLS. BUILDER TO PROVIDE CERTIFICATE OF                                             CONSTRUCTION.
        FROM TOE OF NOSING. STAIRS MUST COMPLY WITH THE NCC FOR SLIP                         INSTALLATION AND COMPLIANCE. PROVIDE MECHANICAL                                                                                                                                                                  NOTES & LEGENDS
        RESISTANCE. BUILDER/STAIR MANUFACTURER TO CHECK STAIR                                VENTILATION TO COMPLY WITH AS1668 TO ALL WET AREAS AND                                                FIRE SAFETY: SMOKE ALARM DETECTORS TO BE INSTALLED IN
        COMPLIANCE PRIOR TO STAIR INSTALLATION. IF THERE ARE ISSUES                          ROOMS NOT NATURALLY VENTILATED. ALL TIMBER OR STEEL FRAMED                                            ACCORDANCE WITH AS 3786-2014, NCC PART 3.7.2 & LOCAL QFES                                                  GENERAL NOTES
        WITH HEIGHT, CONTACT ARCHITECT AS SOON AS POSSIBLE. STEPS TO                         WALLS TO WET AREAS TO BE LINED WITH FC OR APPROVED WET AREA                                           LEGISLATION. SMOKE ALARMS IN THE DWELLING MUST: BE
        BE PROVIDED WHERE FALL FROM DWELLING EXCEEDS 190MM.                                  CLADDING, FIXED IN ACCORDANCE WITH MANUFACTURER'S                                                     PHOTOELECTRIC (AS3786-2014) ; AND NOT ALSO CONTAIN AN
                                                                                             SPECIFICATIONS. SUPSPENDED TIMBER OR STEEL FRAMED FLOORS TO                                           IONISATION SENSOR; AND BE HARD-WIRED TO THE MAINS POWER
        GLAZING: ALL ALUMINIUM AND GLAZING TO COMPLY WITH AS 2047                            HAVE WET AREA FLOORING TO ALL WET AREAS, FIXED IN                                                     SUPPLY WITH A SECONDARY POWER SOURCE (I.E. BATTERY); AND BE
        AND NCC VOL 2 2019 PART 3.6 AND ANY OTHER INDUSTRY STANDARDS                         ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.                                                        INTERCONNECTED WITH EVERY OTHER SMOKE ALARM IN THE
        / LEGISLATION, AND MUST BE DESIGNED FOR THE WIND LOADS                                                                                                                                     DWELLING SO ALL ACTIVATE TOGETHER. SMOKE DETECTORS TO BE
        SPECIFIC TO THE SITE AND BUILDING. FOR WINDOWS WHERE THE FALL                        SANITARYWARE: TYPICAL HEIGHTS OF ACCESSORIES: TOILET ROLL                                             LOCATED: IN EACH BEDROOM; AND HALLWAYS (OR ROOMS) THAT
        HEIGHT FROM FLOOR TO GROUND IS 2M OR GREATER, ALL OPENINGS                           HOLDER: 700MM ABOVE FFL; TOWEL RAIL 1100MM ABOVE FFL; HOSE                                            CONNECT BEDROOMS; AND ON THE MOST LIKELY PATH OF TRAVEL TO
        WITHIN 1700MM OF THE FLOOR MUST BE PROTECTED WITH A FALL                             COCK TO FRIDGE RECESS FFL 1900MM ABOVE FFL; SHOWER RAIL                                               AN EXIT ON ANY LEVELS THAT DO NOT CONTAIN BEDROOMS. SMOKE
        PREVENTION DEVICE OR RESTRICTED TO A MAXIMUM OPENING OF                              1900MM ABOVE FFL; SHOWER RAIL INLET: 1800MM ABOVE FFL,                                                DETECTORS MUST BE PLACED MIN. 300MM AWAY FROM WALLS AND
        125MM AS PER NCC REQUIREMENTS. ALL GLAZING IS TO BE IN                               SHOWER MIXER 1200MM ABOVE FFL.                                                                        LIGHT FITTINGS, AND MIN. 400MM FROM AIR-CONDITIONING VENTS OR
        ACCORDANCE WITH AS1288 AND AS 2047. WINDOW SIZES NOMINATED                           BUSHFIRE HAZARD AREAS: BUSHFIRE HAZARD AREAS ARE TO COMPLY                                            BLADES OF A CEILING FAN.
        ARE NOMINAL ONLY. ACTUAL SIZE MAY VARY ACCORDING TO                                  WITH AS3959 & NCC VOL 2 2019 - PART 2.3, 3.7 & 3.10.5 AND AN
        MANUFACTURER. WINDOWS TO BE FLASHED ALL AROUND.                                      APPROVED BUSHFIRE RISK ASSESSMENT REPORT AND / OR BUSHFIRE                                            SUSTAINABLE BUILDINGS: ALL WORKS TO BE IN ACCORDANCE WITH
                                                                                             MANAGEMENT PLAN (AS PREPARED BY A QUALIFIED BUSH FIRE RISK                                            NCC REQUIREMENTS AND APPROVED ENERGY EFFICIENCY REPORT
        LININGS: EXTERNAL CLADDINGS AND INTERNAL LININGS TO BE FIXED                         ASSESSOR).                                                                                            AND ESD CONSULTANT CERTIFICATES IF APPLICABLE. MP 4.1 -
        AND FINISHED IN ACCORDANCE WITH MANUFACTURER'S                                                                                                                                             ACCEPTABLE SOLUTIONS: HOME ADDITIONS TO HAVE ENERGY
        SPECIFICATION. ALL UNTREATED SOFTWOOD TIMBERS USED IN ROOF                           GAS: GAS METER TO BE INSTALLED AS PER AS/NZS 5601 OR GAS                                              EFFICIENT LIGHTING FOR A MINIMUM OF 80% OF TOTAL FIXED
        FRAMING, ARE TO BE FULLY CLAD. THE BUILDER SHALL TAKE ALL STEPS                      CYLINDERS TO BE INSTALLED AS PER AS/NZS 1596:2014 & AS/NZS                                            INTERNAL LIGHTING; HOME ADDITIONS TO HAVE NEW
        NECESSARY TO ENSURE THE STABILITY AND GENERAL WATER                                  5601.1:2013 FOR AN EXCHANGE CYLINDER APPLICATION.                                                     AIRCONDITIONERS WITH AN E.E.R OF 2.9 MIN; HOME ADDITIONS TO
        TIGHTNESS OF ALL NEW AND/OR EXISTING STRUCTURES DURING ALL                                                                                                                                 HAVE ALL SHOWER ROSES AND TAPS SERVING LAUNDRY TUBS,
        WORKS.                                                                               ELECTRICAL FITTINGS: TYPICAL HEIGHTS OF LIGHT SWITCHES: 1300MM                                        KITCHEN SINKS AND BASINS WITH A MIN 3 STAR WATER EFFICIENCY
                                                                                             ABOVE FFL. TYPICAL HEIGHTS OF POWER OUTLETS: GENERAL: 300MM                                           LABELLING AND STANDARDS RATING; ALL TOILET CISTERNS TO HAVE A
        EXPANSION JOINTS, WALLS: 5MM. FLOORS: 8MM. FILL BOTH WITH                            ABOVE FFL; KITCHEN FRIDGE: 1900MM ABOVE FFL; BATH / ENSUITE /                                         DUAL FLUSH SYSTEM AND A MIN 4 STAR WATER EFFICIENCY
        SILICONE RUBBER. GROUT FOR WALL: EPOXY BASED MILDEW                                  LAUNDRY: 1100MM ABOVE FFL. LOCATION OF FIXTURES AND FITTINGS                                          LABELLING AND STANDARDS RATING. THE SUB-FLOOR SPACE OF A
        RESISTANT. GROUT FOR FLOORS: PREPARED GROUT TO BE ACID                               SHOWN ON DRAWINGS ARE INDICATIVE ONLY. FINAL LOCATIONS TO                                             DWELLING MUST BE VENTILATED IN ACCORDANCE WITH NCC VOL 2
        RESISTANT. ALL WALL TILES TO HAVE FC SUBSTRATE. TILING LAYOUTS                       BE CONFIRMED WITH ARCHITECT OR CLIENT ON SITE. ELECTRICAL                                             2019 PART 3.4.1. INSULATION MUST COMPLY WITH AS/NZS 4859.1 AND
        SHOWN ARE INDICATIVE ONLY, FINAL SETOUT TO BE DETERMINED ON                          CONTRACTOR TO ALLOW FOR CONNECTION OF POWER TO A/C,                                                   APPROVED ENERGY EFFICIENCY REPORT AND ESD CONSULTANT
        SITE BY THE TILING CONTRACTOR.                                                       POOL AND HWS PLANT, TO BE CO-ORINATED WITH SPECIALIST                                                 CERTIFICATES IF APPLICABLE.
                                                                                             CONTRACTORS / SUPPLIERS / MANUFACTURERS.
        SANITARY COMPARTMENTS: WATER CLOSETS (WC'S) TO HAVE A                                                                                                                                      DOCUMENTATION: THE CONTRACTOR SHALL CARRY OUT WORKS IN
        MINIMUM CLEAR WIDTH OF 900MM. PROVIDE REMOVABLE HINGES TO                            JOINERY ITEMS: SHALL INCLUDE MANUFACTURED CASEWORK ITEMS,                                             ACCORDANCE WITH THE SIGNED DRAWINGS AND SCHEDULES AND
        DOORS OF SANITARY COMPARTMENTS TO COMPLY WITH NCC AND BE                             INCLUDING: KITCHEN CABINETS AND CUPBOARDS; BATHROOM                                                   ANYTHING REASONABLE INFERRED, AND WITH THE CONDITIONS OF
        READILY REMOVABLE FROM OUTSIDE UNLESS THERE IS A CLEAR                               CABINETS; ROBES. UNLESS NOTED OTHERWISE: NO EXPOSED GABLES                                            CONTRACT, AND IN ACCORDANCE WITH THE DIRECTIONS AND TO THE
        SPACE OF AT LEAST 1200MM B/W CLOSET PAN WITHIN THE SANITARY                          TO JOINERY; ALL EDGES TO BE SQUARE; ALL JOINERY UNITS TO HAVE                                         SATISFACTION OF THE CLIENT & ARCHITECT, WHOSE INTERPRETATION
        COMPARTMENT AND THE NEAREST PART OF THE DOORWAY. PROVIDE                             CARCASS CONSTRUCTED OF 16MM OR 25MM THICK PRE-FINISHED                                                OF THE CONTRACT DOCUMENTS SHALL BE FINAL. THE DRAWINGS AND
        ADEQUATE CLEARANCE AT TOP OF DOOR TO SUIT HINGES.                                    BOARD; ALL LAMINATED JOINERY TO HAVE MATCHING ABS EDGING;                                             SPECIFICATIONS/SCHEDULES SHALL BE CONSIDERED
                                                                                             ALL TIMBER VENEER JOINERY TO HAVE MATCHING SOLID TIMBER                                               COMPLEMENTARY, AND ANY WORK AND/OR MATERIALS ABSENT
        APPLIANCES & EQUIPMENT: BUILDER TO CO-ORDINATE ALL                                   EDGING; ALL DRAWERS TO HAVE HIGH SIDES; ALL ADJUSTABLE                                                FROM ONE BUT PRESENT OR IMPLIED IN THE OTHER SHALL BE
        APPLIANCE AND EQUIPMENT LOCATIONS ON SITE AND WITH JOINER.                           SHELVES SHALL BE SUPPORTED ON BRASS FERRULES AND BUSHES -                                             FURNISHED AS IF THEY WERE PRESENT IN BOTH.
        INSTALLATION AND FINAL CONNECTION BY THE CONTRACTOR.                                 SUPPORTS TO BE AT 50MM CENTRES; ALL HINGED DOORS TO BE HUNG
        JOINER TO CONFIRM ALL APPLIANCE AND EQUIPMENT TOLERANCES                             ON FULLY CONCEALED ALL METAL TYPE WIDE ANGLE HINGES;                                                  FINAL CERTIFICATE: AT COMPLETION OF WORK, BUILDER TO OBTAIN
        AND REQUIREMENTS IN JOINERY PRIOR TO FABRICATION.                                    BUILDER TO PROVIDE ADEQUATE NOGGINGS TO SUPPORT ALL                                                   AND SUPPLY A CERTIFICATE OF CLASSIFICATION FROM A BUILDING
                                                                                             BATHROOM ACCESSORIES AND SUSPENDED JOINERY; FINISH TO                                                 CERTIFIER.
        INTERNAL PAINTING: UNLESS NOTED OTHERWISE PAINT SYSTEM TO BE                         UNDERSIDE OF OVERHEAD CUPBOARDS TO MATCH JOINERY FRONTS.
        DULUX APPROVED 3 COAT SYSTEM - LOW SHEEN FINISH. COLOURS TO                          ALL JOINERY TO BE SITE MEASURED ONCE LININGS ARE IN PLACE.
        BE SUPPLIED BY CLIENT & ARCHITECT DURING CONTRACT AND                                CONFIRM ANY DISCREPANCIES PRIOR TO FABRICATION.
        APPLIED AS PER DULUX'S RECOMMENDATIONS AND GUIDELINES.




                         NOTES & LEGENDS                                                                                          APARTMENT FOR BRIGITTE AND KRIS                                                                                                                                                                 CD - 010.02
                                                                                                                                                                                                                                                                                                                                                                                             B
    H
  RT
NO




                                 GENERAL NOTES                                                                                         UNIT 8 / PACIFIC OUTLOOK 47 ELANDA STREET, SUNSHINE BEACH QLD 4567                                                                                                                       14.12.22        DEVELOPMENT APPROVAL ISSUE             REV


                                     Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies are to be brought to the attention of Minnow Studio. Any dimensions not nominated must be referred to Minnow Studio for confirmation. The concepts and information contained in this document are the copyright of Minnow Studio.

Used in these records

About this file

File size
7.5 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Amended Proposal Plans.pdf · 7.5 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.