Original source · versioned page text
1. Medium Density Residential Code
Performance Outcomes Acceptable Outcomes
Not applicable.
AO21.2
For a lit sports court:
1. the court is located at least 60 metres
from the external wall of an existing or
approved dwelling on adjoining or
nearby premises (as measured from
the centre line of the court); and
2. the vertical illumination resulting from
direct, reflected or other incidental
light emanating from the site does not
exceed 8 lux when measured at any
point 1.5 metres outside the boundary
and at any level from ground level
upward; and
3. any floodlighting is restricted to the
types that give no upward component
of light were mounted horizontally (i.e.
a full cut off luminaire).
Complies.
AO21.3
Mechanical plant and equipment will be suitably
Mechanical plant is-
located to ensure that it does not adversely impact
adjoining premises or visible from the street.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.