RSL Care = Proposed RSL Retirement Village, Cooroy - Road and Rail Noise Assessment (Revised) 4.3 ASSESSMENT OF MONITORING RESULTS Table 4.1 presents the Lama noise levels measured by Air Noise Environment at the site boundary adjacent to the Cooroy Connection Road (see Figure 1). TABLE 4.1: MAXIMUM NOISE LEVELS AT THE DEVELOPMENT SITE BOUNDARY FRONTING THE COOROY CONNECTION ROAD (dB(A)) Source of Data Lamax (Free-Fletd) Continuous unattended monitoring 87 (Average) Attended noise monitoring of train noise 89 The attended noise measurements at the boundary of the site have determined that the average Lamax Noise level of a passing trains is approximately 87 dB(A). Hence, the internal criteria (average Lamax) is predicted to be exceeded by up 40 dB(A) and 35 dB(A) for sleeping and living areas respectively. The noise levels indicated in Table 4.1 were measured at the site boundary, at a distance of 40 m from the passing trains. Mitigation options for reducing noise levels to within the Noosa Shire Council internal criteria are presented in the following sections. 4.4 RAIL NOISE MITIGATION 4.4.1. Acoustic Barrier and Construction Material Requirements Further noise calculations have been completed to determine the effectiveness of an acoustic barrier, as identified on Figure 8. The acoustic barrier is suitable for providing attenuation for both toad traffic noise (as discussed in Section 5.6) and rail noise. It is assumed that the barrier is constructed of a material with a mass density of 12 kg/m? and is continuous with no air gaps. Tables 4.2 and 4.3 present predicted Lama noise levels associated with train noise. TABLE 4.2: PREDICTED WORST-CASE Lamax NOISE LEVELS (FACADE-CORRECTED) FOR ILU BUILDINGS Worst-Case Predicted Lams Noise Levels dB(A) ILU No.' Bed 1 Bed 2 Terrace Side Facade Front Facade Facade Facade | (Sliding Door) | (Living/Dining/Kitchen) (Living) 1 74 83 77 75 82 2 73 83 76 73 80 3 82 80 71 71 80 4 82 85 76 74 83 5 71 82 75 72 81 6 80 80 74 72 81 AIR NOISE ENVIRONMENT PTY LTD INETWORK/PROJECTS/1750/REPORTING/2008 REVISION/1750REPORTO4.ODT Page 9
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2398 - Revised Noise Report and cover letters to referral agencies [As Published]Related documentApplication case desk ↗
About this file
- File size
- 6.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.