RSL Care ==
Proposed RSL Retirement Village, Cooroy - Road and Rail Noise Assessment (Revised) ——

 

 

 

 

 

 

 

 

 

 

 

ILU No.’ Required Noise Reductions for Achieving Internal Noise Levels
o Bed 1 Bed 2 Terrace Side Facade Front Facade
Facades | Facades | (Sliding Door) | (Living/Dining/Kitchen) (Living)
120 29 29 16 20 16
121 29 28 20 22 16
122 29 28 22 22 18
123 28 29 15 18 14
124 28 28 15 18 14
125 28 27 20 21 14
126 27 27 13 18 12

 

 

 

 

 

 

 

TILU Building numbers are identified on Figure 7

TABLE 5.6: CONSTRUCTION CATEGORY REQUIREMENTS FOR ALL OTHER BUILDINGS

 

 

 

 

 

 

 

 

 

 

Noise Reduction Requirements for Construction Materials
Receptor
Ground Floor First Floor

ACF-SW 29 30

ACF-NW 26 29

ACF-NE 16 24

ACF-SE 28 30
Apartment 25 27

Village 23 -

 

 

 

1 Receptor positions are identified on Figure 7

6.6.2 Construction Category Requirements
AS 3671 classifies a Noise Reduction of > 10 dB up to 25 dB as a Category 2 construction:

‘Category 2. Standard construction except for lightweight elements such as fibrous cement
or metal cladding or all-glass facades. Windows, doors and other openings must be closed.
TNR of approximately 25 dB(A) is expected.’

AS 3671 classifies a Noise Reduction of > 25 dB up to 35 dB as a Category 3 construction:

‘Category 3. Special construction, chosen in accordance with Clause 3.4. Windows, doors
and other openings must be closed. TNR of approximately 25 and 35 dB(A) is expected.’

Based on the required noise reductions presented in Tables 5.5 and 5.6, all proposed buildings
require either Construction Category 2 or 3 specifications. Air conditioning units should be provided
for all rooms requiring category 2 or 3 construction to allow adequate ventilation for occupants while
maintaining acoustic performance.

 

AIR NOISE ENVIRONMENT PTY LTD
INETWORK/PROJECTS/1750/REPORTING/2008 REVISION/1750REPORTO4.0DT Page 31

Used in these records

About this file

File size
6.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_2398 - Revised Noise Report and cover letters to referral agencies [As Published].pdf · 6.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.