Council archive · source document
07/2398 - Revised Noise Report and cover letters to referral agencies [As Published] · 132007.2398
RSL Care = Proposed RSL Retirement Village, Cooroy - Road and Rail Noise Assessment (Revised) — 7 CONCLUSION 7.1 RAIL NOISE Impacts of noise associated with the Cooroy Railway Corridor have been investigated by the assessment of unattended and attended noise monitoring data completed at the proposed development site. Based on the noise monitoring results, it is predicted that train noise levels passing by the proposed retirement village will exceed the relevant internal Lama noise criterion by up to 40 dB(A). Compliance with the internal noise criteria is likely to be achieved provided the following mitigation options are implemented: ® an acoustic barrier is constructed at the boundary of the devetopment site along the Cooroy Connection Road (as shown on Figure 8). The acoustic barrier should have a mass density of 12 kg/m? and be continuous with no air gaps; = all rooms requiring a noise reduction of greater than 10 dB (as identified on Tables 5.5 and 5.6) should be provided with air-conditioning; and = the Care Facility, Apartment and Village centre should be constructed of materials which meet the required STCs as specified in Tables 5.8. Based on the predicted noise levels and proposed tayouts, STC requirements for a number of (LU windows are predicted to be above 40 (as shown in Table 5.7). In order to reduce the STC requirements for [LU buildings to those presented in Tables 5.9 and 5.10, the following options should be considered: = replace ILU Buildings 3, 4, 30 with Type 1 ILU layouts; = construction of ILU Buildings 93, 95, 96, 98 to 100, 102, 103, 106, 109 to 115 and 117 with an alternative layout as presented on Figure 9; = for the alternative design, an acoustic barrier extending at least 1 metre from the Bedroom 2 wall should be constructed. The barrier should be 1.8 m above the finished floor level and be located adjacent to the Bedroom 2 window (see Figure 9); and = replace Type 4 double unit ILU Buildings 94, 97, 101, 104, 105, 107, 108, 116 and 118 with an alternative design. Bedroom areas should be provided furthest from the Cooroy Connection Road. This is likely to involve the provision of living areas to the rear of the ILU building. Currently, no alternative layouts have been made available to replace the Type 4 double units (Buildings 94, 97, 101, 104, 105, 107, 108, 116 and 118) located near the Cooroy Connection Road. If double units are provided by combining two mirrored alternative single units, window STC values of 37 are likely be achieved for these buildings. However, if alternative designs to those presented in Figure 9 are proposed, an acoustic assessment of these units would be required to determine the required construction materials. AIR NOISE ENVIRONMENT PTY LTD INETWORK/PROJECTS/1750/REPORTING/2008 REVISION/1750REPORT04.0DT Page 47
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2398 - Revised Noise Report and cover letters to referral agencies [As Published]Related documentApplication case desk ↗
About this file
- File size
- 6.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.