Skip to the record
Noosa's #1 Council Tracker.

Council archive · source document

08/0215 - Op Works - Landscaping, Sediment & Erosion, Frontage Stormwater, Filling, Car Parking & Acess [As Published] · 142008.215

of 47

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

 

 

 

aa

Requirements for Sustainable Buildings for new Class 1 building and
a sole-occupancy unit of a new Class 2 building, and renovated
bathrooms in an existing Class 1 and a sole-occupancy unit of an
existing Class 2 building.

Acceptable Solutions:

to reticulated mains water supply areas only
ar rating under Hiciency Labelling
Scheme (WELS) or a AAA rating when assessed against AS/NZ
6400:2005 Water Efficient Products -rating and labelling.

Water Pressure Limiting: (to reticulated mains water supply areas
only)

The maximum pressure level of water from any outlet within the
property boundaries of a new Class 1 building must not exceed
500kPa. Compliance can be achieved through the installation of a
water pressure limiting device in line with the water meter.

Where it is known that the pressure level of the water supply does not
exceed 500kPa, a water pressure limiting device is not required.

Dual Flush Toilets:
Toilets must have a dual flush capacity that does not exceed 6 litres
on full flush and 3 litres on half flush.

Energy Efficient Lighting:

Energy efficient lighting includes fluorescent and compact fluorescent
lights. It does not include incandescent or halogen fights. Energy
efficient lighting is to be used for at least 40 percent of the total floor
area of the building or sole occupancy unit. (Floor area means the
area of a room measured within the finished surfaces of the walls, and
includes the area occupied by any cupboard or other built-in furniture,
fixture or fitting)

This area includes associated garages.

Where a part of a house is lit by more than one light source, and one
or more of those light sources is not deemed to be efficient lighting,
then that part of the house is not considered to have efficient lighting,
and therefore does not qualify towards the 40% efficient lighting
requirement.

Hot Water Supply: In a new Class 1 building.

A suitable hot water system includes:

(a) a gas hot water system with a five star energy rating; or

(b) a heat pump or a solar hot water system where:

(i) in a building with 3 or more bedrooms, the hot water system, must
be eligible to receive at least 22 Renewable Energy Certificates; or
(ii) In a building with 1 or 2 bedrooms the hot water system must be
eligible to receive at least 14 Renewable Energy Certificates.

 

 

BIRAGKAIEN DUPLEX
181 GYMPIE TERRACE
NOOSAVILLE

 

 

 

 

 

ANDREW MCKELLAR DESIG
62 IILTON TERRACE
NOOSAVILLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DRAWING SCHEDULE

1.0 Cover page and Drawing Schedule

1.1 Ground Floor Plan
Second Floor Plan
Roof Plan

Door Schedule
Window Schedule
Section A

Section B

Section C

Section D

Section E
Elevations
Elevations

Ceiling Plan; External Cladding

 

 

 

Used in these records

About this file

File size
5.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

08_0215 - Op Works - Landscaping, Sediment & Erosion, Frontage Stormwater, Filling, Car Parking & Acess [As Published].pdf · 5.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.