7 March 2017
SCG Ref: 26281(L1)


By email: [email protected]


Attention: Marcus Brenan
Noosa Town Planning



Dear Marcus

                                     Re: 46-48 Elizabeth Street, Noosaville

With regards to Council’s recent Information Request Notice issued on the 23 January 2017 for the above
application we also provide the following comments to the points of the Engineering issues raised.

Issue 1 – Stormwater ponding on adjoining properties

We have revised our current Stormwater Drainage Plan for the site to include a series of pits and pipes along the
proposed boundary retaining walls. These will drain the existing areas of potential ponding identified during a site
visit and further survey information recently obtained.

The areas straddle the common boundary between the subject site and the adjoining properties and confirms that
ponding would already be occurring on the adjoining properties. The included drains will provide relief drainage
from those properties which is equal to the minimum overflow levels that currently exists within the subject site.

Issue 2 – Acid Sulphate Soils

The site is to be filled to satisfy Council’s minimum floor level height requirements. No excavation will be required
therefore avoiding a potential for exposing Potential Acid Sulphate Soils (PASS).

The influence on the existing ground water levels as a result of the filling will not result in any PASS being exposed
to oxygen which could lead to acid leaching. Tidal height variations that occur within the ground water will exceed
any height variations as a result of the fillings.

Issue 3 – Vehicle Maneuvering

We have included a copy of our vehicle turning template drawing for Council’s approval.

Issue 4 – Frontage Works

We have specified on our revised drawing that a new 2m wide concrete footpath be provided across the site’s
frontage.
Full text of the other 1 page

Page 2

We trust that the attached revised drawings satisfy Council’s request for information.

Please do not hesitate to contact he undersigned should further clarification be required.


Yours faithfully




Sean Richardson – RPEQ 5835
For and on behalf of
SCG CONSULTING ENGINEERS


Cc:      Kidd & Co (By email: [email protected])


Encs     SCG Consulting Engineers Drawing Nos.            26281-OW1 thru OW7 & SW1 Issue 2




      SCG Consulting Engineers                      Page 2 of 2                              SCG Ref: 26281(L1)

Used in these records

About this file

File size
164 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

SCG 26281(L1).pdf · 164 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.