Council archive · source document
Approved Plans OPW18/0118
Plans and drawings: the text below has words only, no drawings.
3 3
SP264909 SP264909
18
RP151412
01
-
S
S
EXISTING BUILDING
S
IL 4.54 BUND HEIGHT = 0.3m PROPOSED 600x600 EXISTING STORMWATER
5.0 FIELD INLET PIT TO REMAIN
S
600x600 BASIN D D S
D D
OUTLET PIT D D D D D
5.5
D D SL 5.59
D D D
PROPOSED HEADWALL
S
IL 4.89
6.5
WITH ROCK SCOUR
S
19 PROTETION
RP151412 S S S S S S S S S S S S S S S S
S S S S S S
S 5.5 S
S S S S S S S S S S S S S S S S S S S S S S S S S
4.5
S
6.0
S
S S S S S S S S S S S S S S S S S S S
S S S S
S
S
S
S
S
S
S
S
5.0
S
SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF
S
S
S S S S S 4.5 5.5
S S
5.0
S
S S
4.0
S S S
S S S S S S S S
S
S
3.
5
S
4.5
S
S
3.0
S
S
S
S
RESERVE WORKS LEGEND
1. REINSTATE DEMOLISHED GRAVEL WITH 150mm DEEP PROPOSED TURF ON 150mm
TOP SOIL AND TURF DEEP TOP SOIL
PROPOSED GRAVEL BUND EXISTING TOP OF BATTER
EXISTING TOE OF BATTER
OPW18/0118 25 SEP 2018
|X|
E EXISTING TIMBER WALL
EXISTING SURFAC
100
EXISTING FENCE
100
S EXISTING SEWER
250
APPROVED PLAN
NOOSA COUNCIL
D EXISTING STORMWATER
600
PROPOSED TOP OF BATTER
IL 4.54
PROPOSED TOE OF BATTER
PROPOSED EARTHWORKS BUND
D PROPOSED Ø450 PVC STORMWATER
PIPE
Ø450 OUTLET PIPE TO 600x600 BASIN
-
REGULATE OUTFLOW OUTLET PIT SF PROPOSED TEMPORARY SEDIMENT
FENCE - REFER IECA STANDARD
Ø450 STORMWATER DRAWINGS SF-01 & SF-02
PIPE
PROPOSED STORMWATER INLET PROTECTION
IN ACCORDANCE WITH IECA STD DRG OG-01
SECTION 01
J:\2017\17548ID2_Goodchap_Street_Carpark\4.CADD\#ACAD\17548_CIVIL.dwg
1:25 @ A1 -
1:50 @ A3
0 2 4 6 8 10m
1:200 (A1) 1:400 (A3)
COPYRIGHT © Associated Consultants Client Drawn Verified Project Drawing Title Scale Sheet Size
This drawing is subject to NV SP
copyright in accordance with the
Designed Verified
CARPARK GENERAL ARRANGEMENT AS SHOWN A1
agreement between Tod
Consulting pty ltd (tc) and tc's
client. This drawing shall only be
NV SP GOODCHAP STREET, NOOSAVILLE PLAN Drawing Number
used for this specific project. Approved
S. PRYSTUPA
RPEQ No
1137 RDP 17548_C002
This drawing shall not be used
Noosa: 07 5449 9600 LOCAL AUTHORITY
Sunshine Coast: 07 5329 3190 Mackay: 07 4840 2337 Signed MCU APPROVAL HORIZ DATUM 0 10 20 30 40 50 60 Sheet Revision
for construction until marked as PO Box 61, Noosaville, QLD 4566
A 23.3.17 PRELIMINARY ISSUE NV ROL APPROVAL VERT DATUM
'issued for construction' in the
revision description. Rev Date Revision Description Drawn
[email protected] www.todconsulting.com
ABN 39 128 805 336
23.3.17 OPW APPROVAL RL DATUM MEASUREMENT BAR - INCREMENTS IN mm
2 of 2 A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans OPW18/0118 .pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.