BUILDING WORKS SETOUT GENERAL NOTES TERMITE PROTECTION WALL & FLOOR LEGEND
Building Works to be setout by Licensed Surveyor. Toilet doors are to open outwards or be fitted with lift off The building shall be protected from subterranean termites
hinges in accordance with part 3.8.3.3 of BCA Housing by approved physical and/ or chemical barriers in RC Block
Identification and height verification survey to be carried Provisions. accordance with AS3660.1.
out once fascia/gutter and ridge to roof has been erected Reinforced Concrete
to confirm no works encroach boundaries and the building All glazing in buildings to comply with the requirements of The precise method of protection shall be determined by
has been constructed in accordance with approved plans part 3.6 of BCA2006 Housing Provision and AS1288/2005. the owner/ s and/ or builder only after consultation with a Timber Framed Wall
and height does not exceed 9.0m height limit as per the A glazing certificate from the manufacturer for compliance licensed pest control operator.
local planning scheme. with AS1288 must be provided on completion. FFL 3.500 Finished Floor Level generally designers
This information then shall be advised to the Local
Where existing crossover is modified the builder shall Government or Licensed Certifier prior to, or at the time of Structural Floor Level generally
ENERGY EFFICIENCY construct Kerb & Channel to match adjacent and to local lodgement of the Building Permit Application.
SFL 3.500
REQUIREMENT authority requirements. +SL 3.500 Spot Level
Pro Therm "Reflecta Cell" 7mm insulation to be installed to Thereafter, the owners shall ensure that any physical
all roof spaces (excluding decks) to manufacturer's All Balustrading to Decks shall be engineer certified. barriers are kept clear of garden beds and/ or soil build up, RL 3.500 Reduced Level
direction. that any chemical barriers remain undisturbed and that PO Box 262
Builder to allow for disposal from site all waste annual inspections (plus eradication as necessary ) are TOW 3.500 Top of Wall level Noosa Heads QLD 4567
Pro Therm "Reflecta Shield" 4mm insulation to be installed materials during demolition and construction period. carried out thoughout the life of the building by a licensed
pest control operator in accordance with AS3660.1.
GFA Telephone
Mobile
07 5447 5633
0419 758 478
to all exterior framed walls and framed floors in HOUSE AREAS
accordance with manufacturer's direction Smoke alarms must comply with AS 3786 and be
LOWER 209m2 [email protected]
All external doors and windows to be fitted with a seal to connected to the consumer mains power. Smoke alarms On the completion of the building prior to the final
UPPER 187m2
restrict air infiltration must be located in accordance with part 3.7.2.3 of the inspection by the licensed Building Certifier, a licensed www.kiddco.com.au
Total 396m2
building code of Australia. Pest Controller is to inspect and confirm that the termite
system installed has not been bridged or breached and the This drawing is to be read in
Hot water systems shall be fitted with a heat trap within BASEMENT 264m2 conjunction with Engineers Drawings &
required visual barrier has been maintained.
one metre of the outlet of the heater and before the first TANKING OF HABITABLE AREAS Site Cover Reports
branch. All steps in floors where retaining walls have been Site Area 607.04m2
Construction to comply
installed or where retaining walls are used as external
SUB-FLOOR VENTILATION Site cover 242.67m2(39.99%) with all relevant SAA &
All exhaust fans to conditioned spaces to be fitted with a walls of habitable rooms are to be waterproofed by an Note: The sub-floor space beneath the suspended floor of BCA Codes & standard
self closing damper. approved tanking system and installed by an accredited a building must be designed and constructed in Bldg By-law 1975 & as
accordance with Part 3.4.1.2 of BCA 2007 Housing amended
installer. Verify all dimensions on
Provisions.
EXCAVATIONS site prior to commencement
Sheet Piling to be designed and certified by RPEQ so as The approved system is to be certified for compliance of any works. These
upon completion. drawings are not to be
to support likely imposed loads and not cause or allow used for scaling
damage to adjacent building works or land. Copyright for design &
WATER PROOFING WET AREAS drawings remain the
property of the authors.
All boundary works, including temp. works not to encroach Waterproofing of wet areas to comply with AS3740-2004.
over boundary. A certificate including bathrooms, WC and laundry from an
approved waterproofing applicator will be required before
Builder to make allowance to prop, shore and retain the a final certificate can be issued.
sides of all excavations required for building construction.
The builder shall satisfy himself as to employ prior to
commencing 'any' excavation. Any slippage or damage STORMWATER
caused as a result of excavation shall be made good by Roof & surface stormwater to be disposed of in
builder. Adequate retention methods are the full accordance with local authority requirements
responsibility of the builder.
SEWERAGE
SURFACE WATER DRAINAGE Connection of house drains to sewer main to be carried
The ground beneath suspended floors must be graded so out in accordance with local authority requirements
that the area beneath the building is above the adjacent Project
external finished ground level and surface water is Proposed House
prevented from ponding under the building. Refer figure WATER SUPPLY
3.1.2.3 of BCA 2007 Housing Provisions. Water Supply: Connect to estate mains in accordance with Location
development approval and local authority requirements 15 Ross Crescent
The external finished ground level surrounding the building Sunshine Beach
must be graded to a slope not less than 50mm over the If mains water pressure exceeds or could exceed 500kPa, Client
first 1.0m from the building in accordance with Figure a water pressure limiting device shall be installed to
3.1.2.2 of BCA 2007 Housing Provisions. ensure that the maximum operating pressure at any outlet
Mark Bain
Drawing Title
within the boundaries of the property does not exceed 500 COVER SHEET
The finished ground level is to be a minimum of 150mm kPa.
below ground floor level. Scale Date
as shown @A3 22.03.16
Drawn By Job No:
JLK 1801
Drawing No. Issue No.
GSPublisherVersion 0.81.100.100
WD.101 S1