Maintaining a maximum ambient air temperature of 28C throughout the kitchen is important. At
higher temperatures, grease particles are less likely to form droplets making it difficult for filters and
odour control systems to effectively remove them.
A maximum humidity level of 70% will ensure the efficient performance of an activated carbon
system.
The makeup air supply should be designed to provide approximately 85% of the extract flow rate.
◼ Good housekeeping, cleaning, and maintenance
Best management practices in handling the accumulation, storage and disposal of food wastes and food-
preparation wastes are important in preventing the escape of fugitive odour towards nearby receptors.
Routine cleaning of both kitchens and waste areas will eliminate residual fats and other organic matter
reducing their potential to emit odour as a result of their decomposition. Waste management plans
developed for both the entire development and each commercial kitchen will address any waste-related
air and odour issues.
Similarly, periodic cleaning and maintenance of odour control equipment and ventilation systems will
ensure that these systems continue to function effectively.
237401.0145.R01V02 Page 14
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 10-Air Quality and Odour Assessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.