Original source · versioned page text
2017-01-16 General Committee Agenda
The original of this document is very large (15.2 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.
GENERAL COMMITTEE MEETING AGENDA 16 JANUARY 2017
TABLE 1
NOISE LIMITS AT A SENSITIVE RECEPTOR
Noise level at noise sensitive place measured as the adjusted
PERIOD
maximum sound pressure level (L10, adj,T)
7am – 6pm Background noise level (L90,T) plus 5 dB(A)
6pm – 10pm Background noise level plus 5 dB(A)
10pm – 7am Background noise level plus 3 dB(A)
NOISE LIMITS AT A COMMERCIAL PLACE
Noise level at a commercial place measured as the adjusted maximum
PERIOD
sound pressure level (L10, adj,T)
7am – 6pm Background noise level (L90,T) plus 10 dB(A)
6pm – 10pm Background noise level plus10 dB(A)
10pm – 7am Background noise level plus 8 dB(A)
Acoustic Report
16. An acoustic report prepared by a suitably qualified person* is to be submitted to council
confirming assessment and certification of measured noise levels from the new mechanical
plant and equipment, a/c units, motors, refrigeration equipment, compressors, pumps etc
comply with the noise limits as set out in Table 1 and all other relevant noise conditions of
this Decision Notice associated with Stage 4 of the development.
17. The report is to be submitted after commissioning any new equipment (with aall plant and
equipment operating at the same time) and when all building extensions are complete.
18. Measurement of sound pressure levels (adjusted for tonality and impulse) must be in
accordance with Australian Standard AS1055.1 “Acoustics – Description and measurement
of environmental noise – General procedures”.
Suitably Qualified Person* - Certification
For the purpose of measuring and certifying compliance with relevant noise conditions of this
Decision Notice, a suitably qualified person is either:
i. a Registered Professional Engineer of Queensland, or
ii. an environmental consultant with a minimum of three (3) years current experience in
the field of acoustics.
Outdoor Lighting Devices
19. Lighting associated with the use must be designed, sited, installed and tested to comply with
Table 2.1 & 2.2 of Australian Standard AS4282-1997 “Control of the obtrusive effects of
outdoor lighting” using a control level of 1 and not cause a nuisance to the adjacent
residential areas.
20. Vehicle headlight emissions from the carpark are to be adequately shielded to prevent
spillage beyond the site into any adjacent residential buildings.
Page 7 of 146
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.