Council archive · source document
10/0515 - Lot reconfiguration (4 to 2) [As Published] · 152010.515
pe cae + 5 : re) € ensure fi ‘ling: or excavation does Tot adversely impact upon “other premises by— i. causing ponding of water on the sife or nearby land; ii. increasing flooding, which adversely affects the safety or use of any land upstream and downstream; and iii, adversely affecting the flow of water in any overland flow path. .|:Sloping sites and ridgelines ,017 Development on sloping sites— a) is responsive to the natural topography of the site ‘and minimises cut , and fill; bb) does not visually dominate the hill slope or interrupt the. skyline; c) is integrated with the natural site characteristics including vegetation; “| d) for Multiple housing, takes the form of small separate buildings; AND 018 On steep slopes or ridgelines which are visible from the major road network, areas of public open space, the Noosa River or the beaches— a) new buildings and structures including outbuildings, are designed so as not to dominate or detract from the scenic and environmental qualities of the site and its setting; and b) the external colour scheme of:buildings is designed to blend with the natural elements of its surroundings. . “* . CadCon Surveying & Town Planning flows to that infrastructure; and b) the infrastructure. has the capacity to accept any additional loading. AND $16.3 For Residential Uses— a) where slab on ground construction is used, filling does not extend more than 1m beyond the building footprint and access to car parking areas, measured from the outer walls of the building ; or b) the design consists of a suspended floor construction; AND $16.4 Car parking and maneuvering areas are constructed at a level that permits the parking area to drain from the site by gravity means, without the need for mechanical pumping; or $16.5 Basements for residential uses have flood immunity above the Q100 where alternative means to mechanical pumping are used to achieve such immunity; or $16.6 Basements for non-residential uses have flood immunity above the Q100 that may be achieved by means of mechanical pumping where the mechanical feature is installed with adequate holding tanks and an alternative back up power source. $17.1 Buildings and associated access “ways are not constructed on land with a slope greater than 1 in 4 (25%); AND $17.2 Buildings are of split level design that step down the slope or have a suspended floor construction; AND $17.3 Cut or fill is less than 2m in depth; AND $17.4 The distance between the ground and the lowest part of the floor. of the building does not exceed 3m to avoid large under building areas; AND $17.5’ Buildings do not present as more storeys’ than is allowed in the relevant zone. $18.1 No solution provided Paae 5 of 7 Complies The proposed reconfiguration will not change the existing topography of the site. There are no earthworks proposed as part of this application.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
10/0515 - Lot reconfiguration (4 to 2) [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.