Council archive · source document
20517 App O.pdf [As Published] · 132007.1259
VY 2.6 2.7 2.8 2.9 (vii) (viii) aceon \ WAYS Consultants must be taken to protect the sign surface from direct sunlight as this can heat the surface to a point where it becomes too hot to read by touch maps and plans must be aligned with the building or accessway. where large open spaces exist around an Identification Sign, Tactile Ground Surface Indicators (refer to AS1428.4) must be used to provide additional location cues. Directional Signs must be: (i) (ii) (ii) (iv) (i) positioned at every change of level, in the lift lobby area, stairways, ramps, escalators and travelators. positioned at every change of direction where the accessway provides more than one directional choice located at entry points on the property boundary on the accessway to indicate the location of major information signs and principal public entries located so that it is encountered from every approach. designed to ensure that the raised tactile and Braille information is placed in a zone between 1200mm and 1600mm above the finished floor surface. The sign must always be positioned from the top measurement. Identification Signs must be: (i) (ii) (ii) (iv) (v) provided to identify all rooms leading from an accessway provided to identify all toilet facilities, washrooms, showers, and rooms where facilities have been provided which could be used by a person with a disability whether that person is a public-visitor, staff member, a short term guest or patient. positioned so that the top of the sign is 1600mm above the finished floor level (a) on the wali, on the latch side of the door with the leading edge of the sign located between 50mm and 300mm from the architrave; or (b) if there is insufficient space on the latch side wail, an Identification Sign may be placed on the non-latch side wall in a location where the reader will not interfere with the path of travel through the opening door; or (c) where (a) or (b) is not possible, the sign may be placed on the door itself. Where the sign is placed on the door the door must be fitted with a self closing device and the sign must not be placed on the outward opening face of a door that opens outwards. located when a door with double leaves is provided and one leaf is designated as the inactive leaf, the inactive leaf is considered the latch side wall. located when a door with double leaves is provided and both leaves are active, then signs must be placed on both sides of the opening, on the approach side from the accessway, on the hinge side walls. Safety/Statutory Signs must be: (i) (ii) (iii) (iv) provided to identify all Required Exits and Fire Exits provided to identify services which could be used to protect the safety of other people who may be in the building generally in the same positions as Identification Signs, and on Required Exits and Fire Exits at a height of 400mm to the top of the sign. Other signs within the Building not described in 2.4 to 2.8 are not required to be Raised Tactile and Braille. Page: 15 of 23
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20517 App O.pdf [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.