Council archive · source document
20517 App O.pdf [As Published] · 132007.1259
necreaus \ WAYS Consultants Where used, TGSI’s must have a minimum 30% luminance contrast with the surrounding surface (integrated units) or 45% to 60% luminance contrast with surrounding surface (discrete units). Refer to AS1428.4- 2002. Note: Discrete units do not comply with the Building Code and if used will need to be proposed as part of an Alternative Solution as required by the BCA. Luminance Contrast — Stairway/Ramp Handrails Handrails on stairways and ramps which comply with AS1428.1-2001 must have a minimum 30% luminance contrast with the surface they are viewed against (at 45°). Detection of handrails by people who are Vision Impaired or have Low Vision is significantly improved when this minimum luminance contrast requirement is achieved. Luminance Contrast - Signage (Visual and Raised Tactile) The letters and graphics on all signs must have a minimum 30% luminance contrast with the background surface, the background surface must have a minimum 30% luminance contrast with the surface or frame (sign structure) it is viewed against. Braille (where provided) must be the same colour as the background it is viewed against ie., no luminance contrast 61.7 Luminance Contrast — Kerbs Where a kerb is provided between a pathway and a roadway the kerb must be coloured so that it provides a minimum 30% luminance contrast with both surfaces. 6.1.8 Luminance Contrast — Light Switches/GPO’s. Light Switches and GPO’s must have a minimum 30% luminance contrast with the surface they are viewed against to assist with the location of same by people who have low vision or a vision impairment. Where the wall surface and the switch plate do not provide sufficient contrast a border of 10mm minimum thickness which provides 30% luminance contrast must surround the switch plate. 6.1.9 Luminance Contrast — Doorways All doorways (the door and/or the door frame) must have a minimum 30% luminance contrast with the surrounding wall surface. This is to assist with location by people with a Vision Impairment or Low Vision. 6.2.1 Pedestrian Surfaces — Vertical Transitions. Page: 6 of 23
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20517 App O.pdf [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.