Council archive · source document
response to information request 3 henderson · MCU22/0145
22 February 2023 Nadine Gorton Noosa Council [email protected] RE: Response to Information Request (MCU22/0145 & OPW22/0212) Multiple Dwelling Units and Associated Operational Works situated at 3 Henderson St, Sunshine Beach Council issued a further information request on 20 September 2022. The following additional information provides a response to Council’s Information Request items: 1. Provide an amended landscape plan that details existing vegetation to be retained or removed. 2. Remove the comments on the landscape plan ED22266 PO – 02 that detail removal of vegetation on the adjoining site. 14. Provide amended plans that detail additional tree species to the front of the site to screen the development whilst providing opportunities for views from decks. The updated landscape drawings from Element Design include the outlines of trees to be removed and replaced with suitable species and details of screening vegetation along the edges of the site to ensure screening to adjoining premises. Large tuckeroos and Coastal Banksias are provided within the frontage and road reserve to screen any of the built form from the street.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 4 pages
Page 2
3. Provide amended plans that provide additional texture to the external finishes
of the northern and southern elevations. Additional materials are to be applied
to the blank block walls to ensure compliance with the Code
4. Provide a colour scheme for the development utilising understated colours.
11. Provide amended plans that highlight the individual units through staggering
and variation to the roof form and using different materials and textures for
the units.
12. Provide amended plans that demonstrating that the proposed upper level
decks, windows along the southern elevation and roof top area do not
overlook adjoining residences private open space or into adjoining windows.
Please note that the tall planting on the roof deck is not considered a sufficient
privacy screen.
The built form has been substantially amended to ensure the units provide variation in
both materiality and appearance. As described below, a mix of stonework, board,
concrete, timber battens and paint colours are proposed in a coherent manner to provide
for a high end (yet able to be maintained) building addressing Henderson St. Privacy
screens are also included to side and rear elevations to ensure there is no overlooking of
neighbouring dwellings.
Page 2 of 5
Page 3
5. Provide amended plans that detail compliance with height in storey provisions
and remove the upper level roof form beyond the stairwell and lift area.
6. Provide amended plans that detail compliance with AO5.2 of the High-Density
Residential Zone Code.
7. Provide confirmation that the basement (measured from the basement floor to
ground floor level) meets scheme provisions.
8. Provide additional sections and elevations that clearly detail the existing and
finished ground levels.
13. No sections of the roof top terrace area including screens are to exceed the
height limit.
The plans have been amended with ground lines (existing and proposed) as well as 1m
above the ground line clearly marked on all sections and elevation plans. The plans
demonstrate a compliant basement being screened with planters along the outside of the
walls and limited to a maximum of 6m opening for vehicle access. Furthermore, no part of
the building is more than the 12m height limit.
Page 3 of 5
Page 4
9. Provide amended plans that detail the roof terrace balustrade, roof top terrace
pool, architectural blade wall, roof top privacy screen wall setback at 10
metres.
The boundary encroachment to the top floor deck/pool is minor in nature consisting of
small areas of planter and pool of the upper most level to the front boundary. The front
setback complies with PO9 for the following reasons:
• The proposal is consistent with setbacks of multiple dwellings in Park Cr and Crank
St where larger units exists with similar setbacks as that proposed.
• The wall and pool are located to the front of the building and cannot be seen from
the rear neighbouring properties.
• Does not obstruct views as the neighbouring property to the west faces the other
direction and the subject site views over the roof of the eastern property.
• Given the relaxation is to the front boundary, the structures will not cause
overshading of nearby properties.
• The structures subject to the encroachment do not appear bulky to or dominate the
front elevation as the structures are architecturally pleasing being a privacy wall
and a swimming pool.
Page 4 of 5
Page 5
10. Provide amended plans that detail a 2 metre landscape setback to the visitor
parking at the front of the site.
Amended plans are provided including over 2m of landscape setback to the visitor parking
spaces.
15. Provide additional detail on the access driveway. The detail must be prepared
by a Registered Professional Engineer of Queensland and include but not be
limited to:
15.1. The full extent of the earthworks proposed including the transitions to
the adjoining verge areas. Please note that the transitions must not
create a trip/fall hazard and Council does not support private retaining
structures in the road reserve
15.2. Indicate the depths of cuts on the longitudinal section of the access
driveway
15.3. A longitudinal section of the footpath extending to 5m beyond the
prolongation of the side boundaries of the subject site
15.4. The grades of the verge areas adjacent to the path and between the path
and the kerb and channel.
16. Provide an amended stormwater plan that includes:
16.1. The detail of the connection of the drain grate at the entrance to the
garage to the overall drainage system. Please note that Council does not
support pump systems (Dual Occupancy and Multiple Dwelling Code,
PO14).
16.2. The discharge rate at the kerb and channel and sufficient detail to
demonstrate that the discharge will not create a traffic hazard. Please
note that Council is unlikely to accept a discharge that exceeds 25l/sec
17. Provide a plan of the vehicle swept paths for each space that is sufficient to
demonstrate that vehicles can access the parking space in a forward gear,
manoeuvre on site and exit the site in a forward gear in a total of 3 movements.
Please note that the plan must:
17.1. be prepared by a Registered Professional Engineer of Queensland,
17.2. be the path of a B99 vehicle as described in AS/NZS2890.1:2004, and
17.3. assume that the adjacent space is occupied
18. Provide a plan that indicates the dimensions of the various carspaces. Please
note that the spaces must be in accordance with AS/NZS2890.1:2004.
HR Design Consulting Engineers provide the compliant detailed driveway section, swept
paths and updated stormwater plans.
----------------------------------------------------------------------------------------------------------------------
Pursuant to the Development Assessment Rules, the applicant has given the assessment
manager the information requested. Please continue with your assessment in accordance
with the DA Rules. If you have any further queries in relation to the above, please do not
hesitate to contact myself.
Regards,
Jack Lewis B.Sc Hons UNSW M.Plan Otago
Planner/Director
Pivotal Perspective Pty Ltd
0406 334 227
Page 5 of 5
Used in these records
response to information request 3 henderson.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.