Council archive · source document
response to information request 3 henderson · MCU22/0145
10. Provide amended plans that detail a 2 metre landscape setback to the visitor
parking at the front of the site.
Amended plans are provided including over 2m of landscape setback to the visitor parking
spaces.
15. Provide additional detail on the access driveway. The detail must be prepared
by a Registered Professional Engineer of Queensland and include but not be
limited to:
15.1. The full extent of the earthworks proposed including the transitions to
the adjoining verge areas. Please note that the transitions must not
create a trip/fall hazard and Council does not support private retaining
structures in the road reserve
15.2. Indicate the depths of cuts on the longitudinal section of the access
driveway
15.3. A longitudinal section of the footpath extending to 5m beyond the
prolongation of the side boundaries of the subject site
15.4. The grades of the verge areas adjacent to the path and between the path
and the kerb and channel.
16. Provide an amended stormwater plan that includes:
16.1. The detail of the connection of the drain grate at the entrance to the
garage to the overall drainage system. Please note that Council does not
support pump systems (Dual Occupancy and Multiple Dwelling Code,
PO14).
16.2. The discharge rate at the kerb and channel and sufficient detail to
demonstrate that the discharge will not create a traffic hazard. Please
note that Council is unlikely to accept a discharge that exceeds 25l/sec
17. Provide a plan of the vehicle swept paths for each space that is sufficient to
demonstrate that vehicles can access the parking space in a forward gear,
manoeuvre on site and exit the site in a forward gear in a total of 3 movements.
Please note that the plan must:
17.1. be prepared by a Registered Professional Engineer of Queensland,
17.2. be the path of a B99 vehicle as described in AS/NZS2890.1:2004, and
17.3. assume that the adjacent space is occupied
18. Provide a plan that indicates the dimensions of the various carspaces. Please
note that the spaces must be in accordance with AS/NZS2890.1:2004.
HR Design Consulting Engineers provide the compliant detailed driveway section, swept
paths and updated stormwater plans.
----------------------------------------------------------------------------------------------------------------------
Pursuant to the Development Assessment Rules, the applicant has given the assessment
manager the information requested. Please continue with your assessment in accordance
with the DA Rules. If you have any further queries in relation to the above, please do not
hesitate to contact myself.
Regards,
Jack Lewis B.Sc Hons UNSW M.Plan Otago
Planner/Director
Pivotal Perspective Pty Ltd
0406 334 227
Page 5 of 5
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records