Site Access and Driveways
24. A sealed access driveway must be provided from Doonella Street to all parking
and maneuvering areas of the development generally in accordance with the
approved plans (16416–SD02 dated 02/05/2017 by Archicology). The works
must be undertaken in accordance with an Operational Works approval and must
include in particular:
a. A driveway crossover 4.0m wide with grades generally in accordance with
IPWEAQ standard drawings SEQ R-049 and R-050 with line marking and
modified driveway tapers at 45 degree at the kerb line to encourage left-in
and left-out from the site (refer to Parking & Traffic Impact Assessment
Report – Addendum 1, Reference 210442017TIA-Add, dated 21 April 2017
by Greys Australia Pty Ltd).
b. Signage and linemarking in accordance with Manual of Uniform Traffic
Control Devices (MUTCD) installed within the site to indicate left-out only
traffic.
c. Grades to allow for a compliant concrete pathway along the frontage.
d. Any landscaping, fences and fixtures near the access entry point must
comply with AS 2890.1 requirements for sight visibility for pedestrians and
cyclists at driveways.
Frontage Reinstatement Works
25. All redundant driveways and existing kerb laybacks along the frontage of the site
must be removed and the kerb, footpath and verge area reinstated to match the
balance of the site frontage, including the provision of topsoil and turf where the
existing verge is grassed. The works must be undertaken in accordance with an
Operational Works approval and must include in particular:
a. The existing driveway layback be removed and the kerb reinstated to match
the type and alignment of the adjoining existing sections of kerb line. The
driveway layback must be saw-cut and removed to allow for a smooth and
neat join finish between the new and the existing kerb.
b. Reinstatement of concrete footpath to provide even and consistent
gradients in longitudinal and across profiles generally in compliance with
IPWEAQ standard drawing SEQ R-065 Concrete Pathway Construction
Details, this may necessitate replacement of sections of the existing
footpaths beyond the edges of the redundant driveways and the frontage
of the site.
c. Any affected trees within the grassed verge must be replaced with similar
species in accordance with the landscaping conditions of this permit.
Car Parking
26. A minimum of 54 car parking spaces must be provided and marked on the site
generally in accordance with the approved plans. The works must be undertaken
in accordance with an Operational Works approval and must include in particular:
a. 3 disabled parking spaces within the total.
b. 3 visitor parking spaces within the total, which are clearly marked for that
purpose and accessible at all times for visitor use.