LEGEND
ROAD WORKS AND DRAINAGE EARTHWORKS WATER SUPPLY
DESCRIPTION PROPOSED EXISTING FUTURE DESCRIPTION PROPOSED EXISTING FUTURE DESCRIPTION PROPOSED EXISTING
600Ø FINISH SLAB LEVEL FL 101.15
STORMWATER PIPELINE FL 4.35 WATER SUPPLY 150Ø uPVC
BULK EARTHWORKS LEVEL BE 101.00
.643 .0 82
ROOFWATER CONNECTION PIPE EARTHWORK LEVELS 100 106 WATER SUPPLY 100Ø uPVC
STORMWATER DRAINAGE PITS CONTOURS 5.6 5.4 WATER SUPPLY 63Ø PE100
SANITARY SERVICES BATTER SANITARY DRAINAGE
WATER SUPPLY STORMWATER PIPELINE STORMWATER DRAINAGE
UNDERGROUND ELECTRICAL STORMWATER DRAINAGE PITS WATER SERVICE POINT (METER)
CONCRETE PAVEMENT
WATER RETICULATION HIGH POINT HP HP
(REFER DRG 4302 & 4303 FOR DETAILS)
ROCK ARMOURING SEWER RETICULATION LOW POINT LP LP
FH FH
BATTERS UNDERGROUND ELECTRICAL FIRE HYDRANT (DUAL OUTLET PILLAR)
CONTOURS 5.6 5.4 TABLE DRAIN/SWALE SLUICE VALVE
TABLE DRAIN/SWALE ROCK BOULDER RETAINING WALL SCOUR VALVE
STORMWATER CATCHMENT NAME G32 G44 CONCRETE SLEEPER RETAINING WALL TEST/CLORINATION POINT
STORMWATER CATCHMENT BOUNDARY
CUT
STAGE BOUNDARY
FILL SANITARY DRAINAGE
ROCK RETAINING WALL DESCRIPTION PROPOSED EXISTING
SANITARY DRAINAGE 150Ø DN
CONCRETE SLEEPER RETAINING WALL EROSION AND SEDIMENT CONTROL
DESCRIPTION PROPOSED EXISTING FUTURE WATER SUPPLY
ACOUSTIC FENCE FINISH SLAB LEVEL FL 101.15
BULK EARTHWORKS LEVEL BE 101.00 FL 4.35
STORMWATER DRAINAGE
CUT ALLOTMENT CONTROL
101.705
POINT FINISH SURFACE LEVEL
FILL
UNDERGROUND ELECTRICITY
SEDIMENT FENCE (OR AS DIRECTED BY
SITE SUPERINTENDENT SEWER MANHOLE NUMBER 1 E
SEWER LINE NUMBER 16 101
DIRTY WATER DIVERSION DRAIN ALIGNMENT
IS INDICATIVE ONLY - CONTRACTOR TO
ENSURE DIRTY WATER SITE RUN-OFF IS
DIRECTED TO SEDIMENT TRENCH THROUGH
ALL PHASES OF CONSTRUCTION
CLEAN WATER DIVERSION DRAIN ALIGNMENT IS
INDICATIVE ONLY - CONTRACTOR TO ENSURE
CLEAN WATER IS DIVERTED THROUGH SITE
DURING ALL PHASES OF CONSTRUCTION
CONCRETE SLEEPER RETAINING WALL
ROCK BOULDER RETAINING WALL
ENTRY/EXIT POINT
SPILL THROUGH WEIR LOCATION (INDICATIVE)
-
NOOSA COUNCIL GULLY INLET PROTECTION
APPROVED PLAN SEDIMENT BASINS CATCHMENT BOUNDARIES
OPW17/0055 13 APR 2017
N.S.C. REF NO. MCU15/0111 & REC15/0031
REVISION DATE ISSUE DETAILS DRAWN DESIGN DRAWN STATUS SCALE CLIENT PROJECT DRAWING TITLE
A 30.01.17 ORIGINAL ISSUE NA BF FOR APPROVAL PALM LAKE WORKS PTY LTD PALM LAKE RESORT
2 NOT FOR CONSTRUCTION STAGE 4 & 5 LEGEND
3
4 DESIGN APPROVED 19 TRADING POST ROAD - COOROY
5 ANDREW McPHAIL RPEQ 6921 PROJECT No. DRAWING No. REVISION
6 DISCLAIMER
7
C 2015 www.calibreconsulting.co CONSTRUCTION. USE WRITTEN DIMENSIONS ONLY, DO NOT SCALE.
16-003302
ALL DIMENSIONS TO BE CHECKED ON SITE BY CONTRACTOR PRIOR TO 4101 A
8 FOR & ON BEHALF OF CALIBRE CONSULTING (QLD) PTY LTD