Original source · versioned page text
Civil Plans SCG 31131-OPW-2022.04.05.pdf
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
Date: Drawn Design
Checked: Drg No. Rev.
Rev. - 10.06.16
[OCR of page images]
DRAWING SIZE — At
www.dialbeforeyoudig.com.au
SAY DIAL1100
yy BEFORE YOU DIG
HEIGHT DATUM
Lot 1 on RP130594 & Lots 80 &
81 on RP71151
Level Datum AHD /I
Level Origin PSM115316, RL 3.593m wy
Survey information provided by Noosa
Cooloola Land Surveys Pty Ltd }
Drg No. 21215DET
EXISTING CONDITION SURVEY
A PHOTOGRAPHIC SURVEY OF THE EXISTING KERB &
CHANNEL AND FOOTPATHS FRONTING THE SITE IS TO
BE COMPLETED AND ISSUED TO COUNCIL PRIOR TO
THE PRE-START WORKS MEETING WITH COUNCIL.
EXISTING SURVEY INFORMATION DOESNT INDICATE
EXISTING WATER MAINS. UNITYWATER MAPPING
INDICATES A 300 DIAM. RISING MAIN PLUS 100 DIAM
MAIN. CONTRACTOR TO LOCATE AND PROTECT
THROUGHOUT WORKS.
LEGEND
_--777 INDICATES EXISTING SURFACE CONTOURS
48.07 AND LEVELS TO AHD.
418.0 EXISTING SURFACE SPOT LEVELS.
— ———_ INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
— SW/EX
INDICATES EXISTING SEWER LINE
INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES STORMWATER DRAIN EXISTING
AS NOTED
KE
EX. SWPT EXISTING STORMWATER PIT
RC. HW.
EX. SMH
E.0.B.
K&C
N.S.L.
FH.
TP
EP.
KERB
REINFORCED CONCRETE HEADWALL
EXISTING SEWER MANHOLE
EXISTING EDGE OF BITUMEN
EXISTING KERB & CHANNEL
NATURAL SURFACE LEVEL
FIRE HYDRANT
TELSTRA PIT
ELECTRICAL POWER POLE
EXISTING KERBING
1113.47
(From Unity Water Records) “\
N x \ er ” Wotep
\
\
\
\
2
0°
+
SITE PLAN — EXISTING SURVEY AND SERVICES PLAN
Scale 1: 200
. EXISTING SEWER MAIN WORKS REFER
“§ \ \ BAX ENGINEERING FOR RELOCATION AND
\ CONNECTION REQUIRMENTS/DETAILS
Floor Level RL16.57
_ 79°10°00" 95.916
Floor Level
RL13.47
ans x | 9.9M
«® RP BOUNDARY
“TTS
: +
o \
\ Lot 1 (#93)
Ng RP130594.
ALL SERVICES SHOWN ON THIS PLAN INDICATIVE
ONLY. CONTRACTOR TO LOCATE AND POTHOLE
ALL IMPACTED EXISTING SERVICES PRIOR 10
COMMENCING WORKS ON SITE. ALL SERVICES
ARE TO BE PROTECTED IN ACCORDANCE WITH
THE AUTHORITY RESPONSIBLE FOR THE SERVICE
Lot 80 (#89)
—— 0% we po \ Yo
| EX. SMH Sewer Manhole
\ { es iN3.47 ©
\ \ “ (From Unity Water Regords)
° Obviously incorrect but
\ \ \ » confirm as manhole is full ef water
\ \
Lot 81 (#91) ,
82
SP120~_
EXISTING
INTER-ALLOTMENT
DRAINAGE
Revision | Description Date
“FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
email:[email protected]
DEBUILD T/A
aN Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
web:www.scg-engineers.com
ABN 40 098 481 299
Title:
EXISTING SURVEY PLAN
Project
89-93 Eumundi Noosa Rd,
NOOSAVILLE
Date: Apri 22 Drawn SR Design SR
Checked: Drg No. Rev.
Srchordsn |) |OLTS1 -OW1.1 -
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewLog in to download the original (Civil Plans SCG 31131-OPW-2022.04.05.pdf)