Original source · versioned page text
Civil Plans SCG 31131-OPW-2022.04.05.pdf
.2 6
15
WM
WM
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
THIS DRAWING AND ASSOCIATED DETAILS
MUST BE READ IN CONJUNCTION WITH THE
NOTES CONTAINED ON 31131-N
Date: Drawn Design
Checked: Drg No. Rev.
Rev. - 10.06.16
[OCR of page images]
DRAWING SIZE — Al
www.dialbeforeyoudig.com.au
DIAL1100
BEFORE YOU DIG
81 on RP71151
Level Datum AHD
Survey information provided
Drg No. 21215DET
HEIGHT DATUM
Lot 1 on RP130594 & Lots 80 &
Level Origin PSM115316, RL 3.593m
Cooloola Land Surveys Pty Ltd
by Noosa
4.07
__ 30h 5
4480
RAMP. x.
ww NT IIOI BY
. K ae J
wd
Ow
—— RW —— RW
AL p59'10
6:im_MIN
an
LEGEND
INDICATES PROPOSED SURFACE
CONTOURS AND LEVELS TO AHD.
INDICATES FINISHED SURFACE GRADE
EXISTING SURFACE SPOT LEVELS.
INDICATES DIRECTION OF RAMP UP OR
DOWN AS INDICATED
INDICATES DEPTH OF CUT (NEGATIVE) OR
FILL (POSITIVE) AS NOTED
INDICATES AREA OF FILL
INDICATES AREA OF CUT
INDICATES LOCATION OF SECTION LINES
SITE PLAN — BUILDING PAD LEVELS
Scale 1: 200
S/EX
Sw
—— Sw/EXx
RW
I>.
35" 4,963 <All
ALL SERVICES SHOWN ON THIS PLAN INDICATIVE
ONLY CONTRACTOR TO LOCATE ALL SERVICES
PRIOR TO COMMENCING WORKS ON SITE. ALL
SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY
RESPONSIBLE FOR THE SERVICE
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
INDICATES SEWER LINE PROPOSED AS
NOTED MIN 1 IN 60 FALL UNLESS NOTED
OTHERWISE
INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES STORMWATER DRAIN PROPOSED
AS NOTED MIN 1 IN 100 FALL UNLESS
NOTED OTHERWISE
INDICATES STORMWATER DRAIN EXISTING
AS NOTED
INDICATES POSITION OF RETAINING WALL
DRG OW3.4 FOR DETAIL
SLAB AS DETAILED
FFL AS
tas
| ° IN STRUCTURAL
DOCUMENTS
yw NOMINATED.
ye
aed TX _ FOOTING AS
DETAILED IN
STRUCTURAL
- DOCUMENTS
( wr LEVELS DIAGRAM
TYPICAL SECTION
NOMINATED.
a ea wt __ ft 79°10’00” 95.916 oe 2 oe
RW ——R RW_——-RW_—— RW a eel
2 RW —— RW —— RW —— RW ——RW ——R'
RW —— RW —— RW — — RW —— RW —— RW ”
| 2 a |
L =
2 2 8 |
| | aw 2
RW —— RW
a
2 3 |
| | | YF
2 2 NHI
1 | | | = 2
|
| (Tt |
| | = 2
: Ai) = | .
— ~Te 10°08
<i cc 912 |
SA x S/EX S7EX S7EX S7EX STEX S7EX S7EX SE SEX S/EX [ SXKX DJ S/EX S/EX s/f _\
= =| LY A ~
& ——— = z LOT 100
6S] £ €
3 § RP106085
RW —— RW —— RW
RW RW —— RW —— RW RW RW RW RW
—— T's"
59°
SW, SW, SW,
PX aT EE ek 23.976
THIS DRAWING AND ASSOCIATED DETAILS
MUST BE READ IN CONJUNCTION WITH THE
NOTES CONTAINED ON 31131-N
finnnn-—t_ p+ ‘'m1:200 © Al
1:400 © A3
Rev. - 10.06.16
KE
EX. SWPT EXISTING STORMWATER PIT
EX. RCHW REINFORCED CONCRETE HEADWALL
EX. SMH EXISTING SEWER MANHOLE
EX. SCP EXISTING SEWER CONNECTION POINT
£.0.B. EXISTING EDGE OF BITUMEN
K&Cc EXISTING KERB & CHANNEL
N.S.L. NATURAL SURFACE LEVEL
FH. FIRE HYDRANT
TP TELSTRA PIT
EP. ELECTRICAL POWER POLE/PILLAR
TS. TRAFFIC OR STREET SIGNAGE
WM. WATER METER
KERB EXISTING KERBING
Revision | Description Date
“FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
‘ABN 40 098 481 699
ENGINEERS
DEBUILD T/A
Title:
BUILDING PAD
EARTHWORKS LEVELS
Project
89-93 Eumundi Noosa Rd,
NOOSAVILLE
Date: Drawn
April 22 SR
Design
SR
Drg No. Rev.
re # 31131 -OW3.3} -
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewLog in to download the original (Civil Plans SCG 31131-OPW-2022.04.05.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.