Original source · versioned page text
Proposal Plans with landscape RFI
Existing Eucalyptus/ add a mixture of Callitris, Wallum Banksia,
Existing garden bed Wallum Heath, Allocasuarina, Acronyciha
Callistemon trees
CAFE / BAR / RESTAURANT AREAS includes 3-4 mtre and Lomandra species to keep the coastal/
-add Lomandra around
INTERNAL DINING AREA: 50.7m² high callistemons beachfront character, in accordance with
gardens edge.
N
EXTERNAL DINING AREA: 37.3m² psp 2.
TOTAL DINING: 88.0m²
power pole Existing Rubber
tree
TOTAL CIRCULATION AREA: 116.1m²
NOT TO SCALE footpath
GYMNASIUM 374.5m²
CAR PARKING SPACES: 45
QBCC# 740695
74/84 Currie St M 0417 770 455
7 8 9 10 11 12 Nambour QLD 4560 E [email protected]
13 Australia
14
15
16 This drawing is to be read in
5 17
18 conjuction with Engineers Drawings
GYMNASIUM 19
20 Reports.
6 21 Construction to comply with all current
and relevant Building Act 1975, NCC,
QDC, QCC and as amended.
Verify all dimensions on site prior to
CAFE / BAR / commencement of any works. These
RESTAURANT 22 23 24 25 26 27 drawings are not to be used for
4 28 scaling.
1 29
30 Copyright for design & drawings
31
32 remain the property of the authors.
33
34
35
3 36
37
2
REVISIONS / AMENDMENTS
39 40 41 42 A TP A 13/08/21
38
43
44
45
PROJECT
NOOSA SURF
MUSEUM
CLIENT GRISMAN Keith
NOT TO SCALE
LOCATION
95/3 Hilton Tce
Noosaville
DRAWING TITLE
SITE PLAN
PROJECT N° SCALE
2107 A3
DRAWING ISSUED 13/08/21
DESIGNED BY SKECO
PROJECT DATE 27/04/21
DRAWING BY R.Carter
DW G N° ISSUE
N°
TP101 A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (Proposal Plans with landscape RFI.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 5 pages
Page 2
NOTE
ALL DIMENSIONS ARE APPROXIMATE & SHOULD BE MEASURED
ON-SITE BEFORE COMMENCING CONSTRUCTION WORK
30300
QBCC# 740695
74/84 Currie St M 0417 770 455
Nambour QLD 4560 E [email protected]
Australia
00
194 This drawing is to be read in
conjuction with Engineers Drawings
Reports.
DECK Construction to comply with all current
and relevant Building Act 1975, NCC,
QDC, QCC and as amended.
STORE UNDER STAIRS Verify all dimensions on site prior to
commencement of any works. These
drawings are not to be used for
DECK scaling.
Copyright for design & drawings
remain the property of the authors.
SERVERY WINDOW ELECTRICAL
REVISIONS / AMENDMENTS
FHR
MALE A TP A 13/08/21
BUFFET SERVERY
DUMBWAITER
BAIN MARIE SERVERY
STORE
16650
RESTAURANT
LIFT FEMALE BAR
KITCHEN
COOL
DWC MDF ROOM
(DATA)
KITCHEN
OFFICE
PROJECT
LOADING NOOSA SURF
PORTE
OFFICE
MUSEUM
COCHE
CLIENT GRISMAN Keith
LOCATION
103
95/3 Hilton Tce
50
Noosaville
DRAWING TITLE
13850 5800 EXISTING GROUND
FLOOR PLAN
0
403
PROJECT N° SCALE
725
0 2107 1 : 200 A3
DRAWING ISSUED 13/08/21
DESIGNED BY SKECO
PROJECT DATE 27/04/21
DRAWING BY R.Carter
SD EXISTING GROUND FLOOR PLAN DW G N° ISSUE
1 N°
1 : 200 TP201 A
Page 3
NOTE
ALL DIMENSIONS ARE APPROXIMATE & SHOULD BE MEASURED
ON-SITE BEFORE COMMENCING CONSTRUCTION WORK
QBCC# 740695
74/84 Currie St M 0417 770 455
Nambour QLD 4560 E [email protected]
Australia
This drawing is to be read in
30404 conjuction with Engineers Drawings
Reports.
Construction to comply with all current
6010 and relevant Building Act 1975, NCC,
QDC, QCC and as amended.
Verify all dimensions on site prior to
commencement of any works. These
drawings are not to be used for
8800 scaling.
Copyright for design & drawings
remain the property of the authors.
4 FHR WC
4.0 x 4.0 5 6 7
3 3.7 x 4.2 2.6 x 4.2 2.6 x 4.2
2.6 x 4.0 BATH
1 2
2.5 x 3.8 2.8 x 4.0 REVISIONS / AMENDMENTS
A TP A 13/08/21
KITCHEN
14800
10.8 x 13.8
LIFT
CPD
8.7 x 7.2
18 BAR 16 15 14
BOARDROOM 2.8 x 4.0 2.8 x 4.0 4.0 x 4.0
6.8 x 5.2
TOILETS
CPD
2300
2.8 x 13.8
TOILETS
1090
PROJECT
17
NOOSA SURF
0
6.8 x 5.2
MUSEUM
CLIENT GRISMAN Keith
6700 14200 4600
LOCATION
1
1790 95/3 Hilton Tce
Noosaville
DRAWING TITLE
EXISTING FIRST
FLOOR PLAN
PROJECT N° SCALE
2107 1 : 200 A3
DRAWING ISSUED 13/08/21
DESIGNED BY SKECO
N
PROJECT DATE 27/04/21
SD EXISTING FIRST FLOOR PLAN Offices are for short term lease and must not DRAWING BY R.Carter
1 exceed 20% of Gross Floor Area of the building DW G N° ISSUE
N°
1 : 200
TP202 A
Page 4
NOTE
ALL DIMENSIONS ARE APPROXIMATE & SHOULD BE MEASURED
ON-SITE BEFORE COMMENCING CONSTRUCTION WORK
30300
QBCC# 740695
74/84 Currie St M 0417 770 455
Nambour QLD 4560 E [email protected]
Australia
00
194 This drawing is to be read in
conjuction with Engineers Drawings
Reports.
DECK Construction to comply with all current
and relevant Building Act 1975, NCC,
QDC, QCC and as amended.
STORE UNDER STAIRS Verify all dimensions on site prior to
commencement of any works. These
drawings are not to be used for
DECK scaling.
Copyright for design & drawings
walkway link along frontage linking remain the property of the authors.
parking to the front of the building
ELECTRICAL
REVISIONS / AMENDMENTS
5
FHR MALE A TP A 13/08/21
DUMBWAITER
STORE
16650
6
DIS.
ESP
LIFT FEMALE
RE S
KITCHEN
SO
COOL
CAF
MDF ROOM
EB
(DATA)
AR
KITCHEN
4
1
PROJECT
LOADING NOOSA SURF
MUSEUM
3
CLIENT GRISMAN Keith
2
103
50
LOCATION
95/3 Hilton Tce
Noosaville
DRAWING TITLE
NEW GROUND
FLOOR LAYOUT
PROJECT N° SCALE
2107 1 : 200 A3
DRAWING ISSUED 13/08/21
DESIGNED BY SKECO
N
PROJECT DATE 27/04/21
DRAWING BY R.Carter
SD NEW GROUND FLOOR LAYOUT PLAN DW G N° ISSUE
1 TP203
N°
A
1 : 200
Page 5
CAFE / BAR / RESTAURANT AREAS
INTERNAL DINING AREA: 50.7m²
EXTERNAL DINING AREA: 37.3m²
TOTAL DINING: 88.0m²
TOTAL CIRCULATION AREA: 116.1m²
DECK
QBCC# 740695
74/84 Currie St M 0417 770 455
Nambour QLD 4560 E [email protected]
Australia
This drawing is to be read in
conjuction with Engineers Drawings
Reports.
Construction to comply with all current
and relevant Building Act 1975, NCC,
QDC, QCC and as amended.
2 FG Verify all dimensions on site prior to
181 commencement of any works. These
5 drawings are not to be used for
scaling.
180
MALE Copyright for design & drawings
6FG
FHR ~70m2 remain the property of the authors.
GYMNASIUM
RESTAURANT/ CAFE / BAR
STORE
6
DISABLED REVISIONS / AMENDMENTS
A TP A 13/08/21
LIFT FEMALE
ESP
RE S
SO
COOL
CAF
MDF (DATA) ROOM
EB
AR
KITCHEN PROJECT
NOOSA SURF
MUSEUM
CLIENT GRISMAN Keith
LOCATION
95/3 Hilton Tce
LOADING Noosaville
DRAWING TITLE
3 CAFE BAR
RESTAURANT
PROJECT N° SCALE
2107 1 : 100 A3
N
DRAWING ISSUED 13/08/21
DESIGNED BY SKECO
NOTE PROJECT DATE 27/04/21
ALL DIMENSIONS ARE APPROXIMATE & SHOULD BE MEASURED ON-SITE DRAWING BY R.Carter
BEFORE COMMENCING CONSTRUCTION WORK
SD CAFE BAR RESTAURANT DW G N° ISSUE
1 TP204
N°
A
1 : 100
Page 6
DECK
QBCC# 740695
74/84 Currie St M 0417 770 455
Nambour QLD 4560 E [email protected]
Australia
This drawing is to be read in
conjuction with Engineers Drawings
Reports.
Construction to comply with all current
and relevant Building Act 1975, NCC,
QDC, QCC and as amended.
Verify all dimensions on site prior to
commencement of any works. These
drawings are not to be used for
scaling.
MALE Copyright for design & drawings
remain the property of the authors.
DUMBWAITER
GYMNASIUM GYMNASIUM
374.5m² REVISIONS / AMENDMENTS
NEW
DISABLED A TP A 13/08/21
FEMALE
ESP
COOL
MDF (DATA)
RE S
ROOM
SO
CAF
EB
AR
KITCHEN PROJECT
NOOSA SURF
MUSEUM
CLIENT GRISMAN Keith
LOCATION
95/3 Hilton Tce
LOADING Noosaville
DRAWING TITLE
GYMNASIUM AREA
N
PROJECT N° SCALE
2107 1 : 100 A3
DRAWING ISSUED 13/08/21
22246
DESIGNED BY SKECO
NOTE PROJECT DATE 27/04/21
ALL DIMENSIONS ARE APPROXIMATE & SHOULD BE MEASURED ON-SITE
BEFORE COMMENCING CONSTRUCTION WORK
DRAWING BY R.Carter
DW G N° ISSUE
SD GYMNASIUM N°
1
1 : 100
TP205 A