Council archive · source document
Wd 1-00 - Site Plan · OPW21/0118
Plans and drawings: the text below has words only, no drawings.
NORTH
ELEVATION KEY
PATH
2
WD 2.00
BOUNDARY 15088 190° 30'
1 2
WD 2.01 WD 2.01
0m 3m 6m 9m 12m 15m
1
WD 2.00
VISUAL SCALE 1:150 @ A2
3258 2550
2228 1550
1658
15000
BOUNDARY 40234 100° 30' SITE INFORMATION :
BOUNDARY 40234 280° 30'
RAIN WATER INFILTRATION DRAINAGE
PIT TO HYDRAULIC ENGINEERS DETAIL.
LOT 786 ON RP 48111 AREA SCHEDULE
SITE AREA: 607M² Level Name Area
PARISH: WEYBA
4 X 5000 LITRE CONNECTED POLY UNDERGROUND RAIN WATER COUNTY: MARCH GARAGE ENTRY/ POOL TERRACE 32 m²
STORAGE TANKS, CONNECT TO EXTERNAL TAPS, WASHING MACHINE
AND TOILET CISTERNS. TANK WITH TOWN WATER TOP UP. OVERFLOW GARAGE GARAGE 44 m²
CONNECTED TO RAINWATER INFILTRATION PIT TO HYDRAULIC
ENGINEERS DETAIL
GARAGE INTERNAL AREA 132 m²
LINE OF COASTAL MANAGEMENT SETBACK SOFT LANDSCAPING 230M² = 38% GARAGE TERRACE 1 28 m²
GARAGE TERRACE 2 72 m²
FIRST BALCONY 1 25 m²
FIRST BALCONY 2 6 m²
FIRST INTERNAL AREA 153 m²
TWO STOREY DWELLING
GENERAL NOTES :
- EXISTING BOUNDARY FENCES ARE TO BE DOCUMENTED AND PHOTOGRAPHED PRIOR TO COMMENCING WORKS. IF ANY STRUCTURES, FOOTINGS OR
ENCROACHMENTS ARE FOUND OWNER AND MACCHIA ARE TO BE CONTACTED IMMEDIATELY.
LINE OF GROUND FLOOR LEVEL
- DO NOT SCALE OFF DRAWINGS, CONSULT MACCHIA IF DIMENSION REQUIRED
LINE OF FIRST FLOOR LEVEL
- ALL WORK TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, AUSTRALIAN STANDARDS AND ANY APPLICABLE STATE AND LOCAL REQUIREMENTS
- DRAWINGS TO BE READ IN CONJUNCTION WITH STRUCTURAL ENGINEERS DOCUMENTATION, CONSULT MACCHIA IF DISCREPANCIES OCCUR
- DRAWINGS TO BE READ IN CONJUNCTION WITH SURVEYORS PLAN PROVIDED BY MAX WATTERSON REF 02/137 DATED24.05.2002, BUILDING TO BE SET
OUT ONSITE BY LICENCED SURVEYOR
- HEIGHT OF BUILDING MEASURED FROM NATURAL GROUND LEVEL AS DEFINED BY COUNCIL AND SETOUT BY REGISTERED SURVEYOR, CERTIFICATE OF
COMPLIANCE TO BE PROVIDED ON COMPLETION OF PROJECT
- ALL PROPERTY BOUNDARIES, PROPOSED STRUCTURES, HEIGHTS AND FENCES ARE TO BE SETOUT AND PEGGED BY A LICENCED SURVEYOR.
- DISCHARGE SEWERAGE AND STORMWATER IN ACCORDANCE WITH APPROPRIATE AUTHORITY REQUIREMENTS.
POOL
- ELECTRICAL AND PLUMBING FIXTURES TO BE ENERGY AND WATER EFFICENT TO COMPLY WITH STATE AND LOCAL BUILDING CODE.
GARAGE
- DRAWINGS TO BE READ IN CONJUNCTION WITH PROJECT SPECIFICATION, FINISHES SCHEDULE AND BASIX CERTIFICATE REQUIREMENTS.
2980
27.14 obv - EXISTING DWELLING, DRIVEWAY AND ALL ASSOCIATED GARDEN WALLS AND STRUCTURES TO BE DEMOLISHED AND REMOVED FROM THE SITE.
MATERIALS ARE TO BE DISPOSED OF AT AN APPROVED FACILITY AND HAZARDOUS MATERIALS TO BE DISPOSED AND REMOVED TO AS 2601 CLAUSE
1.6.2 AND TO SAFE WORK AUSTRALIA GUIDELINES. EXISTING SERVICES TO BE CAPPED OFF.
BOUNDARY 15088 10° 30' WM 100
0
PSM 44265 - ALL WORKS TO COMPLY WITH THE APPROVAL CONDITIONS SET OUT IN THE DEVELOPMENT PERMIT FOR MATERIAL CHANGE OF USE- DETACHED HOUSE,
2228 400 RL27.686 ISSUED BY NOOSA COUNCIL DATED 18 NOVEMBER 2016
POWER 2738 1400
DRIVEWAY
POLE
CROSSOVER TO LOCAL COUNCIL REQUREMENTS
GENERAL LEGEND :
WM WATER METER
4000 DRIVEWAY, ENSURE 750MM MINIMUM COVER OVER SEWER
EXISTING STREET TREES TO BE RETAINED. SWP
SWP STORM WATER PIT
EXISTING STREET TREES TO BE RETAINED.
SMH SEWER MANHOLE
27.35 inv
SOFT LANDSCAPING
SMH
RL 28.65
1 : 150 ARAKOON CRESCENT AMOUR RESIDENCE MACCHIA DESIGN STUDIO
E. [email protected] P. 0447 494 202 A. P.O.BOX 365, NOOSAVILLE, QLD 4566
1 SITE PLAN 8 ARAKOON CRESCENT, SUNSHINE BEACH SITE PLAN
REVISION
C POND DELETED, TERRACE 1 AND TRELLIS 14.10.2020 DATE 11.01.2019
©
B
A
NO.
BUILDIING APPLICATION ISSUE
APPLICATION ISSUE
DESCRIPTION
06.08.2020
21.05.2020
DATE
SCALE @ A2 As indicated WD 1.00 C
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
WD 1-00 - SITE PLAN.pdfRelated documentApplication case desk ↗
About this file
- File size
- 345 KB (small file)
- File type
No other editions are linked here.