Council archive · source document
Approved Plans - MCU22/0196 & OPW22/0295
Plans and drawings: the text below has words only, no drawings.
Very large file (11.8 MB): may take a few minutes to open.
Original PDF page 14, section 1. The text section number identifies this passage in the reader.
DRAWING SIZE — At
Level Datum AHD
HEIGHT DATUM
LOT 2 & 3 ON MCH3881
Level Origin PM 105735, RL 4.577 H
Gympie Tce, Noosaville
Survey information provided by | !
Max Watterson & Associates
+180
F,
Ellin
S.L. 12.50
LLL. 12.00
L
L_]
[x] cr2
Ej cP3
(RCS)
Fe
GD-150
—— SWw/EX
Sw
oe RW
48077
LEGEND
EXISTING SURFACE SPOT LEVELS.
INDICATES PROPOSED SURFACE
CONTOURS AND LEVELS TO AHD.
INDICATES DIRECTION OF FALL
TO FINISHED GROUND SURFACE.
INDICATES SURFACE LEVEL (S.L.) AND INVERT
LEVEL (|.L.) OF ADJACENT STORMWATER PIT
DRIVEWAY SLAB/PAVEMENT. REFER TO NOTES
AND DETAILS ON DRG. OW4.1 FOR THICKNESS
AND REINFORCING.
LANDSCAPING, REFER LANDSCAPE
ARCHITECT FOR DETAILS.
600Sq IPWEA TYPE 2A FIELD INLETS,
PRE-CAST CONCRETE WITH HEAVY DUTY
GRATE WHERE INSTALLED IN PAVED
AREAS.
450Sq STORMWATER JUNCTION BOX,
PRE-CAST CONCRETE. AND SEALED
LID. REFER TP DETAIL ON DRG. SW1.2
400Sq GRATED FIELD INLETS, POLY AND LIGHT
DUTY GRATE WHER IN LANDSCAPE AREAS.
ROOF WATER CONNECTION, REFER
HYDRAULIC CONSULANT FOR
INTERNAL DRAINAGE DETAILS,
TYPICAL.
150(W) GRATED DRAIN WITH HEAVY
DUTY GRATE.
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES STORMWATER DRAIN EXISTING
AS NOTED
INDICATES STORMWATER DRAIN PROPOSED
AS NOTED MIN 1 IN 100 FALL UNLESS
NOTED OTHERWISE
INDICATES POSITION OF CONCRETE
SLEEPER RETAINING WALL TO
STRUCTURAL ENGINERS DETAIL.
www.dialbeforeyoudig.com.au
SAY DIAL 1100
‘Wy BEFORE YOU DIG
| FALL LANDSCAPED AREAS 10
| FORMED FLOW PATHS 10 DIVERT
| RUNOFF TO GRATED INLETS 1 in
100 MIN FALL. ALLOW FOR
OVERFLOW TO COUNCIL PARK AT
REAR. TYPICAL
| PROPOSED UNDERGROUND TRAFFICABLE
| WATER TANKS (LU3000 LATTICE
| UNDERGROUND TANK) FOR STOMRWATER
RE-USE FOR NON-POTABLE PURPOSES.
ROOF STORMWATER ONLY MIN CAPACITY
3000 It PER DWELLING.
|
REFER TO HYDRAULICS
CONSULTANT FOR INTERNAL
DRAINAGE.
/ FOR REINFORCING.
7 } oe a,
DRAINAGE PIPE SIZES ——
AS NOTED.
APPROVED COMPACTED
BEDDING SAND.
EX. 3750 RCP
US IL: 0.00 (APPROX.)
DS I.L: UNKNOWN
(ASSET ID 1034208)
ROOF DRAINAGE:
ALL GUTTERS AND DOWNPIPES TO
——_ +r
ae
+ SS
— CHAPLAIN PARK
HH
EX. SMH
ait) O_o
o ——==$__||__-------—__ _
Oo | —————
olo SS
a Oyo} | || Poo C POOL yf
a o|o | “(si 2.350 LH a
pasancng GPS CP3 009 | OT st 2.360 11.300 oO,
Oo [SL 2350 ][SL 2.350 C1 LIL 1.900 y CP3 ¢P3 of
Poh Lik 1.300 JLLL 1.900 DX % SS o / \e Oo
3 |e 4 4% 4%,
NX = 2 oO > 4 4 4 5
FALL |LANDSCAPED AREAS T0 i — T _ \ S is cs CP3
FORMED FLOW PATHS TO DIVERT Lt. \ .
RUNOFF TO GRATED INLETS 1 jn T GPS GPS YN SL._2.100
100 WIN FALL. ALLOW FOR I SL. 2.200 S.L._ 2.200 LL 1.700
OVERFLOW TO COUNCIL PARK AT a] ‘ LL. 1.800 LLL. 1.800 q
REAR] TYPICAL GROUND ROUND SP] TT GROUND GROUND
cl FFL 2.700 FAL 2700 eb FFL 2.700 FFL 2.700 o
Ja|y \AN \@ty ta : om
ae aS oe EHLES ~ ON |e
ie en | 2 2 B
I] yy tA as 4 \
scone) 4° voo NE IDENTIAL |) Vy 3 0 gf \ ESIDEWTIA GPS
iL 1.500 EVEL OPMENT. SL. 2.350 SL 2.550 “vo Lm
LL. 1.500 LL. 1.500 — — 11400
J —_ —_—
fats T LS. : 4A
go g |F- ws ‘
=) 4
h — p S
/ oo . - \ &
2 H Jit _ 3
ai GARAGE / SARAGE | GARAGE GARAGE Re
i FFL 2.200 \ . = FFL 2.200 FFL 2.200 I
2 a) Ps NI LS
~ \ oO ° 4
z= 8 a a a
f H ‘ \ = = \ \
| Sis ili iis
_ 223 ! B
= | WATER [~-==--—, -
oO
| __-
BUILDER TO POT HOLE LOCATE AND | ae -_ SL 685
CONFIRM EXISTING SERVICES LOCATIONS cp. EEE ito
& LEVELS BEFORE ANY EARTHWORKS i ee 2256 uPVC
SL 1.350 r GD-150 SS ee ow = SL. 1.920
ARE CARRIED OUT. REPORT ANY Tol 4 = z mm =P 1 wu a" Lt.
DISCREPANCIES TO THIS FIRM. ee, f 1508 uPVC a LL. 0.750 °
i - +, FH at €
pS =e
~ =NEW 1.8m WIDE FOOTPATH =| 88
2/125x75x4.0 RHS (GALV.) ae j Na ~ Az Az eee ~
LAID AT 1 in 100 MIN. INSTALL TO 1 On I nn ap TEX SWPT cat
NEW KERB ADAPTORS IN = “I “
ACCORDANCE WITH COUNCIL STD = gb LINEMARKING a
DETAIL RS-081 & MAKE ‘ | AEX. STORMWATER PIT
FOOTPATH GOOD. TYPICAL. SL: 1.05
GYMPIE TERRACE | Buitoer To conriRM EXISTING IL: 0.00 (APPROX.)
STORMWATER PIT LEVELS PRIOR 10 (ASSET ID 1003814)
COMMENCING WORKS, REPORT ANY
DISCREPANCIES TO THIS FIRM
DRIVEWAY PAVEMENT. REFER
DRIVEWAY & ACCESS PLAN
SITE PLAN — SITE STORMWATER MANAGEMENT
Scale 1: 200
<> 300mm MIN THK COMPACTED ALL SERVICES SHOWN ON THIS PLAN INDICATIVE ALL STORMWATER FINISHED SITE DRAINAGE IN
GRANULAR MATERIAL UNDER SLAB. ONLY CONTRACTOR TO LOCATE ALL SERVICES ACCORDANCE WITH HYDRAULICS
TRAFFICABLE AREAS PRIOR TO COMMENCING WORKS ON SITE. ALL PIPES TO BE LAID AT CONSULTANTS DOCUMENTATION.
©@— MIN 98% FIELD DENSITY THROUGH
BACKFILL DEPTH. D>900mm
NON-TRAFFICALBE AREAS
COMPACT IN 150mm LAYERS D>400mm
/- \SW PIPE TRENCH/PIPE BEDDING & BACKFILLING
\{_/ UNDER PAVEMENT TYPICAL SECTION
SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY
RESPONSIBLE FOR THE SERVICE
1:100 MIN. UNO.
COMPLY WITH BCA VOLUME 2 PART
3.5.3
KE
EX. SWPT EXISTING STORMWATER PIT
EX. SMH — EXISTING SEWER MANHOLE
EX. SCP EXISTING SEWER CONNECTION POINT
E.0.B. EXISTING EDGE OF BITUMEN
K&Cc EXISTING KERB & CHANNEL
NS.L. NATURAL SURFACE LEVEL
F.H. FIRE HYDRANT
TP TELSTRA PIT
EP. ELECTRICAL PILLAR
KERB EXISTING KERBING
RCEW REINFORCED CONCRETE END WALL
S.V STOP VALVE
W.M WATER METER
RAINFALL
LANDSCAPING ROOF RUNOFF
ee
TO GROUNDWATER
WATER CYCLE DIAGRAMATIC
cS
WATER
TANKS
cs
ON-SITE STORMWATER
PITS, GRATED DRAINS
& JUNCTION BOXES.
RUNOFF TO COUNCIL
INFRASTRUCTURE
Checked:
hunnt———L__p——1__1m1:200 @ Al st ppg 5835
1:400 @ A3 “|S Richardson
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM
THE ARCHITECTURAL DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND
THE ARCHITECTURAL DRAWINGS ARE TO BE REFERRED
TO THE ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL
EXISTING SERVICES WITHIN AND ADJACENT THE
ALLOTMENT AND SHALL ENSURE THAT ALL NEW WORKS
ARE IN ACCORDANCE WITH THE ATTACHED CRITICAL
DEPTH LINE DIAGRAM.
HYDRAULICS
1. HYDRAULIC SERVICES SHOWN ARE DIAGRAMATIC ONLY.
REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF
FIXTURES.
2. ALL SANITARY HYDRAULICS AND WATER RETICULATION
WITHIN THE ALLOTMENT BOUNDARY TO BE IN
ACCORDANCE WITH AS3500.
3. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS
OF AUTHORITIES HAVING JURISDICTION, AFTER OBTAINING
ALL NECESSARY PERMITS AND APPROVALS.
4. THE CONTRACTOR IS TO CONFIRM THE POSITION OF
ALL EXISTING SERVICES AS INDICATED ON THESE AND
ASSOCIATED PLANS PRIOR TO THE COMMENCING OF
WORK.
5. STORMWATER DRAINAGE PIPES SHALL BE CLASS SH
UPVC OR RUBBER RING JOINTED REINFORCED CONCRETE
PIPE LAID AT A MINIMUM GRADE OF 1 IN 100 U.N.O.
JOINS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH
THE MANUFACTURERS REQUIREMENTS.
6. SEWERS 100mm DIAM. UPVC U.N.O. AND LAID AT A
MINIMUM GRADE OF 1 IN 60.
7. WATER SUPPLY PIPEWORK BELOW GROUND IS TO BE ;
63MM DIAM. OR LESS — HIGH DENSITY TYPE 50
CLASS 12 POLYETHYLENE
8. ALL ABOVE GROUND AND INTERNAL WATER SUPPLY
PIPEWORK TO BE TYPE B COPPER.
9. WATER SERVICES ARE NOT PERMITTED IN GROUND
SLABS AND ALL JOINS AND CONNECTIONS SHALL BE
MADE ABOVE THE SLAB.
10. FIRE HYDRANTS ARE TO BE INSTALLED ARE TO BE
INSTALLED IN ACCORDANCE WITH AS2419.1. HOSE REELS
ARE TO BE INSTALLED IN ACCORDANCE WITH AS2441.
11. CLEAN-OUTS, INSPECTION OPENINGS AND CLOSING
CAPS SITUATED IN VEHICULAR OR PEDESTRIAN
PAVEMENTS ARE TO BE FITTED WITH EITHER BRASS OR
CAST-IRON COVERS.
12. ALL IN-GROUND VALVES SHALL BE IN ACCORDANCE
IN APPROVED CONCRETE PATH BOXES.
13. ALL WASTE PIPES AND WATER SERVICES
PENETRATING SLABS TO BE WRAPPED IN AN APPROVED
FLEXIBLE JOINT JOINT WRAPPING.
14. THE TERM ’SERVICE’ REFERS TO THE MINIMUM
INTERNAL PIPE DIAMETER UNLESS NOTED OTHERWISE.
DRIVEWAY
NOOSA COUNCIL
APPROVED PLAN
MCU22/0196 & OPW22/0295
10 OCTOBER 2023
B COUNCIL RFI 06.09.23
A WATER RE-USE TANKS ADDED 27.02.23
Revision | Description Date
Iss
* FOR APPROVAL
drawings are copyright and are not to be used or reproduced
the written permission of SCG Consulting Engineers.
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
without
C) St
ABN 40 098 481 899
DEBUILD T/A
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
Title:
PLAN
STORMWATER MANAGEMENT
Project
130-152 Gympie Tce,
Noosaville
Drawn
Pate: Sent 22 1H
Design
Drg No.
52225-SW1.1
TH
B.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans - MCU22/0196 & OPW22/0295Related documentApplication case desk ↗
About this file
- File size
- 11.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.