DRAWING SIZE — At
HEIGHT DATUM
LOT 2 & 3 ON MCH3881
Level Datum AHD ih
Level Origin PM 105735, RL 4.577
Gympie Tce, Noosaville
Survey information provided by | /
Max Watterson & Associates
SITE_DEWATERING
— THE SITE IS TO BE CONSTANTLY DE-WATERED UNTIL THE GROUND
LEVEL SUSPENDED SLAB IS POURED.
— THE DESIGN AND INSTALLATION OF THE DEWATERING SYSTEM IS TO
BE BY A SPECIALIST CONTRACTOR.
—APPROX GROUND WATER TABLE OF 1.0m BELOW EXISTING GROUND
LEVEL. SEASONAL & TIDAL VARIATIONS NOT CONSIDERED
—GIVEN THE CLOSE PROXIMITY TO THE NOOSA RIVER, GROUNDWATER
LEVELS WILL VARY WITH TIDAL INFLUENCE AND PREVAILING WEATHER
CONDITIONS.
—EXTRACTED GROUNDWATER IS TO BE TREATED IN ACCORDANCE WITH
RECOMMENDATIONS PROVIDED IN A FUTURE DEWATERING MANAGEMENT
PLAN & SITE GEOTECHNICAL REPORT
— TREATED EXTRACTED GROUNDWATER IS TO BE DIRECTED TO COUNCIL
STORMWATER, FINAL OUTLET LOCATION TO BE APPROVED BY NOOSA
COUNCIL.
— PUMPING MUST NOT CAUSE NUISANCE FOR NIEGHBOURS. ENCLOSING
WITHIN A SOUND PROOF ENCLOSURE MUST BE CONSIDERED.
TEMPORARY CFA PILED RETAINING WALLS
— CFA PILED RETAINING WALL DESIGN AND INSTALLATION
BY A SPECIALIST CONTRACTOR
— DRIVING OF PILE WALLS NOT PERMITTED
— INSTALLATION OF GROUND ANCHORS INTO NEIGHBORING
PROPERTIES NOT PERMITTED WITHOUT OWNERS CONSENT
— ADDITIONAL MEASURES SUCH AS GROUTING THE JOINTS
IS RECOMMENDED TO REDUCE GROUNDWATER INFLOWS.
— PROVIDE GROUND MONITORING/VIBRATION CONTROL
DURING INSTALLATION.
— ESTABLISH SURVEY MONITORING POINTS ALONG PILED
WALL TO MONITOR WALL ALIGNMENT/ GROUND MOVEMENT
ESTABLISH SURVEY MOITORING POINTS ALONG PILE WALL
CAPPING BEAM TO MONITOR WALL ALIGNMENT/GROUND
MOVEMENT, PILING CONTRACTORS ENGINEER TO BE ADVISED OF
ANY OBSERVED MOVEMENT
Ground /
pad Teve
UNSTABLE
&
te, 2
THIS FOOTING IS FOUNDED oo
BELOW CRITICAL DEPTH PY, Lid
LINE AND IS STABLE. STABLE ye oN
PIERS OR UNDERPINNING FOUNDED
BELOW THE CRITICAL DEPTH LINE
WOULD BE NEEDED TO SUPPORT
ANY FOOTING THAT IS FOUNDED
ABOVE THE CRITICAL DEPTH LINE. 30 De
Horizontal
CRITICAL DEPTH LINE
LEGEND
48.077
+180
/D
FILL (POSITIVE) AS NOTED
INDICATES AREA OF CUT
INDICATES AREA OF FILL
EXISTING STRUCTURE /DWELLING
INCLUDING NEIGHBOURING
ALLOTMENTS
THE BUILDER /CONTRACTOR
SHALL CONFIRM ALL
RELEVANT LEVELS PRIOR 10
COMMENCING WORKS.
I
t
| THIS FOOTING WITHOUT
t_ PIERS |S FOUNDED
ABOVE CRITICAL DEPTH
LINE AND IS UNSTABLE.
|
I
{
\ UNE OF PROPOSED
\—"— EXCAVATION OR OTHER
| TRENCH.
|
I
|
ees
NOTE:
THIS DETAIL ALSO APPLIES TO EXISTING
FOUNDATIONS ON NEIGHBOURING
PROPERTIES. SHEET PILING MUST BE
INSTALLED WHERE EXISTING FOOTINGS WILL
BE FOUNDED ABOVE ANY EXCAVATION
CRITICAL DEPTH LINE
--~~ INDICATES PROPOSED SURFACE
CONTOURS AND LEVELS TO AHD.
EXISTING SURFACE SPOT LEVELS.
INDICATES DEPTH OF CUT (NEGATIVE) OR
INDICATES POSITION OF TEMPORARY
RETENTION SHORING, DESIGN
INSTALLATION BY SPECIALIST
AND
CONTRACTOR
— E — INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
w——_ INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
a INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES STORMWATER DRAI
AS NOTED
IN EXISTING
INDICATES POSITION OF RETAINING WALL
TO STRUCTURAL ENGINERS D
www.dialbeforeyoudig.com.au
BEFORE YOU DIG
ETAIL.
BUILDER TO MAINTAIN STABILITY
OF ALL NEIGHBOURING STRUCTURES,
REFER CRITICAL DEPTH LINE DETAIL
ON THIS SHEET
bot BASEMENT WALLS TO STRUCTURAL FINAL BASEMENT SLAB THICKNESS TO
Zz | ENGINEERS DETAIL BE DETAILED BY STRUCTURAL KE
wo | ENGINEER
ce |
a ! PAVEMENT AS EX. SMH
s|= ? RAFT SLAB 10 DETAILED ON DRG a
I STRUCTURAL ows. K&C
1} ENGINEERS DETAIL. NSL.
i 5 FH.
wD Ee FPL AS & EP.
“ez FPL AS NOMINATED. S KERB
| “ NOMINATED. S RCEW
ae a ee | SV
LL) 7 777 TF 7 wa 7 we we 77 y, L/y WM
VLIS LLL AL AK IL LD AL ILIDL AL CLI ALLEL CSL LLL PL LL
eR Ne TANKING WATERPROOF BLANKET WITH
PRIMER & PROTECTIVE COATING INSTALLED
BY SPECIALIST CONTRACTOR TO DRIVEWAY / CARPARK PAVEMENT
MANUFACTURERS’ SPECIFICATIONS &
CERTIFICATION.
FINISHED LEVELS DIAGRAM
FINISHED LEVELS DIAGRAM TYPICAL SECTION
TYPICAL SECTION
——— “Up
———. 7
tL —_——__ -
° => __ CHAPLAIN: PARK ;
AS / N Aah 4
” ri 3p + é
TOP :
BTM :
ENSURE 600mm MIN. BEHIND
PILING TO ALLOW FOR
ACCESS FOR BASEMENT
WALL WATERPROOFING.
TYPICAL.
TOP
BIM
TOP
BTM :
TOP
BIM
EX. SWPT EXISTING STORMWATER PIT
EX. SMH
4.
Se A
RESIDENTIAL
FPL:
a DASHED LINE INDICATE:
X° PROPOSED BUILDING
FOOTPRINT
PILES TO BE BACKFILLED
~~ 7
FOLLOWING BASEMENT K\ |
CONSTRUCTION. i Gy
/ }
——_ ——— x4
DRIVEWAY (0288) te Coat Me
REFER Drg. OW4.1 & QP yo Ni
OW4.2 FOR DETAILS. 1 om
ae
I
—
TOP : 2.10
[BTM : 1.45
H = 0.65m
INDICATES TEMPORARY CFA CONCRETE PILING OR SIMILAR,
DESIGN AND INSTALLATION BY OTHERS. MINIMUM VIBRATION
TECHNIQUES TO BE USED FOR INSTALLATION, VIBRATION
t——— CONTROL AND MANAGEMENT BY PILING CONTRACTOR. BUILDER
TO CONFIRM EXTENT REQUIRED TO SATISFY CRITICAL DEPTH
LINE PROTECTION OF NEIGHBOURING STRUCTURES.
REFER DETAIL.
TOP : 2.50
BIM : 1.50
H = 1.00m
Lo Ei ' | LER EB ESTABLISH SURVEY MOITORING POINTS ALONG PILE WALL
FFL: —0.300 ———— & 51-40 CAPPING BEAM TO MONITOR WALL ALIGNMENT/GROUND
- . . om MOVEMENT, PILING CONTRACTORS ENGINEER TO BE ADVISED OF
-0 700 | Ka ANY OBSERVED MOVEMENT
. Ki
_— | Kt,
I N | t
| x I fy BY 0.600 TOP : 2.10
| ot o | 5 | BTM : 1.55
‘ * | : / H = 0.55m
| 5 N &
LL
TOP : 2.30
| BTM : 1.50
/H= 0.80m
DASHED LINE INDICATES APPROX. ON SITE
STOCKPILE & TREATMENT AREA FOR ACID
| SULPHATE SOILS (ASS). ENSURE SURFACE
GRADES PROMOTE FALL INTO BASEMENT
TERRACE
SITE PLAN — EARTHWORKS & PILING PLAN
Scale 1: 200
PRIOR TO COMMENCING WORKS,
UNDERTAKE DILAPIDATION REPORTS OF
ALL NEIGHBORING DWELLINGS/STRUCTURES
ALL SERVICES SHOWN ON THIS PLAN INDICATIVE
ONLY CONTRACTOR TO LOCATE ALL SERVICES
PRIOR TO COMMENCING WORKS ON SITE. ALL
CONTRACTOR TO REPAIR ADJACENT THE
CONSTRUCTION SITE KERB, FOOTPATH OR
ROAD RESERVE IF ANY DAMAGE IS SUSTAINED
DURING CONSTRUCTION. GRASSED AREAS ARE
TO BE RE TOP SOILED AND TURFED.
SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY
RESPONSIBLE FOR THE SERVICE
SITE GEOTECHNICAL
INFORMATION/ RECOMMENDATIONS PRESENTED IN
PACIFIC GEOTECH REPORT ON GEOTECHNICAL
INVESTIGATION (PROJECT PG-9236) DATED NOV
2022,
NOTE:
CUT/FILL LEVELS SHOWN REPRESENT THE FINISHED PAD
LEVEL (FPL) TO THE UNDERSIDE OF THE GROUND BEARING
SLABS AND PAVEMENTS AND INCLUDES THE CRUSHER
DUST OR ROAD BASE LAYERS 10 BE PROVIDED UNDER THE
SLABS. ADDITIONAL LANDSCAPING FILL NOT INCLUDED.
DILAPIDATION REPORT:
PRIOR TO ANY CONSTRUCTION
UNDERTAKE DILAPIDATION REPORT OF ALL
NEIGHBORING DWELLINGS/ STRUCTURES.
EXCAVATIONS, TYPICAL. FINAL LOCATION
TO BE DETERMINED BY PRINCIPLE
CONTRACTOR.
RC PILES, DESIGN
BY OTHERS
@nen
EXCAVATION DEPTH
V
EXISTING SEWER MANHOLE
EXISTING SEWER CONNECTION POINT
EXISTING EDGE OF BITUMEN
EXISTING KERB & CHANNEL
NATURAL SURFACE LEVEL
FIRE HYDRANT
TELSTRA PIT
ELECTRICAL PILLAR
EXISTING KERBING
REINFORCED CONCRETE END WALL
STOP VALVE
WATER METER
EXISTING GROUND LEVEL
—_ vv
SITE PREPARATION, EARTHWORKS & COMPACTION
SITE PREPARATION, EARTHWORKS, TEMPORARY BATTERS
& COMPACTION TO BE IN ACCORDANCE WITH THE
SPECIFICATIONS AND REQUIREMENTS OF OF PACIFIC
PILE DESIGN BY OTHERS
(OCD CONCRETE PILED RETAINING WALL
GEOTECH REPORT ON GEOTECHNICAL INVESTIGATION
(PROJECT PG-9236) DATED NOVEMBER 2022,
(7 SECTION
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECTURAL DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
ARCHITECTURAL DRAWINGS ARE TO BE REFERRED TO THE
ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL
ENSURE THAT ALL NEW WORKS ARE IN ACCORDANCE WITH
THE ATTACHED CRITICAL DEPTH LINE DIAGRAM.
FILLING NOTES
—THE SITE IS TO BE SCRAPED CLEAR OF ALL ORGANIC
MATERIAL AND DEBRIS.
—THE SUBGRADE IS TO BE ROLLED WITH A VIBRATING STEEL
DRUM ROLLER TO ACHIEVE A MINIMUM RELATIVE FIELD
DENSITY OF 98%. THE COMPACTION IS TO BE SUFFICIENT TO
ACHIEVE A BLOW COUNT OF 7 BLOWS PER 300mm WITH AN
APPROVED PERTH SAND PENETROMETER FOR A DEPTH OF
1.0m BELOW EXCAVATED LEVEL. COPIES OF COMPACTION TEST
RESULTS SHALL BE PRESENTED TO SCG CONSULTING
ENGINEERS FOR APPROVAL.
—UNLESS NOTED OTHERWISE A MINIMUM BEARING CAPACITY
OF 100kPa SHOULD BE ACHIEVED WITHIN COMPACTED FILLING.
COMPACTION & BEARING CAPACITY TEST RESULTS MUST BE
PRESENTED TO SCG CONSULTING ENGINEERS FOR APPROVAL
PRIOR TO WORKS PROCEEDING.
—THE FILL MATERIAL CLEAN GRANULAR MATERIAL (I.E. SAND
TO A CLAYEY SAND IN ACCORDANCE WITH AS1726) BE FREE
OF ANY ORGANIC MATERIAL AND HAVE A CLAY CONTENT OF
LESS THAN 12% (PLASTICITY INDEX LESS THAN 25%, LINEAR
SHRINKAGE OF 15%). THE PROPOSED MATERIAL IS TO BE
INSPECTED BY SCG CONSULTING ENGINEERS PRIOR TO ITS
REMOVAL TO ENSURE ITS COMPATIBILITY.
—THE FILL IS TO BE PLACED AND COMPACTED IN
ACCORDANCE WITH AS3798-1996 TO A LEVEL SUFFICIENT TO
ACHIEVE A LEVEL 2 CERTIFICATION WITH A MINIMUM RELATIVE
FIELD DENSITY OF 98%. COPIES OF COMPACTION TEST
RESULTS SHALL BE PRESENTED TO SCG CONSULTING
ENGINEERS FOR APPROVAL.
FILLING AND COMPACTING ADJACENT EXISTING STRUCTURES
IS TO BE IN STRICT ACCORDANCE WITH THE ASSOCIATED
DETAILS AND SPECIFICATIONS.
—AREAS WHERE EXISTING STRUCTURES OR TREES ARE
REMOVED SHALL BE BACKFILLED WITH THE APPROVED FILL
MATERIAL COMPACTED IN ACCORDANCE WITH AS2870-1996 TO
ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 987.
—ANY LOOSE OR SOFT MATERIAL UNCOVERED IN THE SITE
PREPARATION SHALL BE REMOVED AND REPLACED WITH THE
APPROVED FILL MATERIAL COMPACTED IN ACCORDANCE WITH
AS2870-1996 TO ACHIEVE A MINIMUM RELATIVE FIELD
DENSITY OF 98%.
—SITE DRAINAGE AND SILT PROTECTION MEASURES MUST BE
ISTALLED PRIOR TO CONSTRUCTION COMMENCING.
NOOSA COUNCIL
APPROVED PLAN
MCU22/0196 & OPW22/0295
10 OCTOBER 2023
B COUNCIL RFI 06.09.23
A COUNCIL RFI 27.02.23
Revision | Description Date
Iss
* FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
C) S06
DEBUILD T/A
Title:
EARTHWORKS PLAN
Project
150-132 Gympie Tce,
Noosaville
Date: Sept WD) Drawn Design 1H
Checked: Drg No. Re
15400 @ AS | Fearn |) [O2229 —OW3.1) B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans - MCU22/0196 & OPW22/0295Related documentApplication case desk ↗
About this file
- File size
- 11.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.