Skip to the record
The first. The best. The only NoosaWatch™.

Original source · versioned page text

Development Application - Part 1 of 2 - Covering Letter, IDAS Forms 1 & 6 and Checklist 1 & 4

of 20

Page text read automatically using OCR, there may be inaccuracies

DDD
                                                                               Confirmation
                                                                                                Method of lodgement
                                                                               of lodgement

Applications for operational works involving stormwater drainage

drawings showing:
.
   existing and proposed contours
.
   drainage locations, diameters and class of pipe, open drains and
   easements
                                                                               Dconfirmed
.   manhole location, chainage and offset or co-ordinates and inlet and
   outlet invert levels
.   inlet pit locations, chain age and offset or co-ordinates and invert and
    kerb levels

Applications for operational works involving water reticulation


drawings showing:
.   kerb lines or edge of pavement where kerb is not constructed
.   location and levels of other utility services where affected by water
    reticulation works
.
    pipe diameter, type of pipe and pipe alignment
.  water main alignments
                                                                               D confirmed
.  water supply pump station details (if applicable)
.   minor reservoir details (if applicable)
.  conduits
.   location of valves and fire hydrants
.   location of house connections (if applicable)
.   location of bench marks and reference pegs

Applications for operational works involving sewerage reticulation

drawings showing:
.   location of all existing and proposed services
.   location of all existing and proposed sewer lines and manhole locations
.   location of all house connection branches
.   kerb lines or edge of pavement where kerb is not constructed
.
    chainages
                                                                               Dconfirmed
.
    design sewer invert levels
.
    design top of manhole levels
.
    type of manhole and manhole cover
.
    pipe diameter, type of pipe and pipe alignment
.   location of house connections (if applicable)
.sewer
           pump station details (if applicable)

Applications for operational works involving street lighting

drawings showing:
.  location of all light poles and service conduits
.   location of all other cross road conduits
.
    type of wattage and lighting
                                                                               Dconfirmed
.
    any traffic calming devices
.   additional plans for roundabouts and major roads (if applicable)
.   details of any variations to normal alignment
.   details of lighting levels




                                              Building and operational work assessable against a planning scheme IDAS form 6
                                                                                                              -




                                                                                              Version 1.0 18 December 2009


[OCR of page images]
LILI

 

Confirmation
of lodgement

Method of lodgement

 

Applications for operational works involving stormwater drainage

 

drawings showing:

existing and proposed contours
e drainage locations, diameters and class of pipe, open drains and

 

 

easements ; ; ; [confirmed
¢ manhole location, chainage and offset or co-ordinates and inlet and
outlet invert levels
e inlet pit locations, chainage and offset or co-ordinates and invert and
kerb levels
Applications for operational works involving water reticulation
drawings showing:
e kerb lines or edge of pavement where kerb is not constructed
¢ location and levels of other utility services where affected by water
reticulation works
pipe diameter, type of pipe and pipe alignment
water main alignments (J confirmed

e

e

e water supply pump station details (if applicable)
e minor reservoir details (if applicable)

¢ conduits

e location of valves and fire hydrants

e location of house connections (if applicable)

e location of bench marks and reference pegs

 

Applications for operational works involving sewerage reticulation

 

drawings showing:

location of all existing and proposed services

location of all existing and proposed sewer lines and manhole locations
location of all house connection branches

kerb lines or edge of pavement where kerb is not constructed
chainages

design sewer invert levels

design top of manhole levels

type of manhole and manhole cover

pipe diameter, type of pipe and pipe alignment

location of house connections (if applicable)

sewer pump station details (if applicable)

{_|confirmed

 

Applications for operational works involving street lighting

 

drawings showing:

location of all light poles and service conduits

location of all other cross road conduits

type of wattage and lighting

any traffic calming devices

additional plans for roundabouts and major roads (if applicable)
details of any variations to normal alignment

details of lighting levels

 

(| confirmed

 

 

 

 

 

Building and operational work assessable against a planning scheme - IDAS form 6

Version 1.0 18 December 2009

Log in to download the original (Development Application - Part 1 of 2 - Covering Letter, IDAS Forms 1 & 6 and Checklist 1 & 4.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.