BHA Report for17-19 Hofmann Drive, Noosaville
Direct Flame Contact
Direct flame attack refers to flame contact from the main fire front, the flame that engulfs burning vegetation is the same flame
that contacts the building. It is estimated that only 10 to 20 per cent of buildings lost to bushfire occur as a direct result of flame
attack.
Ember and Firebrand Attack
CSIRO research has shown that ember attack is the cause of up to 80% of house loss in Australia. The convective forces of
bushfire raise burning embers into the atmosphere on prevailing winds and deposit them to the ground ahead of the fire front.
Typically, ember attack occurs approximately 30 minutes prior to the arrival of the fire front and continues during the impact of
the fire front and for several hours afterwards. Building loss via ember attack relates largely to the vulnerabilities and
peculiarities of each building, its distance from the classifiable vegetation and whether someone is present to actively defend
the building.
Radiant Heat
Measured in kilowatts per m2, radiant heat is the heat energy released from the fire front which radiates to the surrounding
environment, deteriorating rapidly over distance. In terms of impacts on buildings, radiant heat can pre-heat materials making
them more susceptible to ignition. Radiant heat can also damage building materials such as window glazing, allowing openings
into a building through which embers may enter.
Fire Driven Wind
The convective forces of a bushfire typically result in strong fire-driven winds, which can lead to building damage. The typical
effects of fire driven wind include conveyance of embers, damage from branches and debris hitting the building, as well as
direct damage to vulnerable building components, such as lifting roofs and the breakage of windows.
+ Bushfire assessments
+ Property vegetation assessments
+ Site planning for bushfire
+ Property management for bushfire Bushfire Planning Specalists - qldbushfireplanning.com.au
Document Set ID: 21969697
+ Bushfire management plans
Version: 2,
1, Version Date: 21/06/2022
20/06/2022
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewLog in to download the original (Attachment C Current Development Approval.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.