Council archive · source document
Compiled Approved Plan - 51988 2740.02 · 51988.2740.02
Plans and drawings: the text below has words only, no drawings.
Very large file (21.6 MB): may take a few minutes to open.
REAL PROPERTY DESCRIPTION
LOT NO: 311
RP/SP: RP164813
PARISH: WEYBA
COUNTY: MARCH
SITE AREA: 646 m²
LOCAL AUTHORITY: NOOSA SHIRE COUNCIL
CONTOURS: 0.25m
DATUM: ASSUMED
SITE COVERAGE: 31.34%
SITE NOTES
1. ALL WORK TO BE CONSTRUCTED IN ACCORDANCE
WITH THE CURRENT NCC INC. AMENDMENTS,
ALSO ANY RELEVANT AUSTRALIAN STANDARDS.
270°0'
2. DRIVEWAY, PATHS CLOTHESLINE & GULLY PITS
W
ARE DIAGRAMMATIC ONLY. FOR SHAPE AND
LOCATION REFER TO BUILDERS SPEC FOR DETAILS.
3. SITE EXCAVATION SHALL BE SUCH THAT A 1M W - SW
NDS WI
WI NT
ER
WIDE BY 1:20 GRADE EXISTS AROUND THE ER ME R PM S
S UM UN
T
PERIMETER OF THE BUILDING AS PER THE
IN
S
PM
RM
W
O
CURRENT NCC REQUIREMENT'S.
SU
ST
ER
N
4. ALL DRIVEWAYS & PATHS ARE TO BE CONSTRUCTED
S UMM
180°0'
TO LOCAL AUTHORITY'S SATISFACTION AND RELEVANT
0°0'
S
EZ ES
BY-LAWS & AUSTRALIAN STANDARDS.
PROPOSED NEW CONCRETE DRIVEWAY
S - SE
5. ALL GROUND LEVELS ARE APPROXIMATE ONLY.
PROPOSED ADDITIONS
BR E
ALTERATION AND PARKING AREAS
WI
AM
6. BUILDER AND TRADES ARE TO CONFIRM ALL 3075 6175
NTE
ER
R
MM
SUM
MER AM SUN
MEASUREMENTS, DETAILS & SPECIFICATIONS
AM
SU
SUN
PRIOR TO SET-OUT AND ORDERING MATERIALS.
SU
SE - MM
TO OMP TO GARAGE
NE ER
BREEZ ES PM
BEAMS / LINTELS
BEAMS / LINTELS HAVE NOT BEEN DESIGNED TO 1500 5900 4000 2175
90°0'
E
TAKE GIRDER TRUSSES. IF BEAMS ARE REQUIRED TO
TAKE GIRDER TRUSSES CONTACT AN ENGINEER FOR
APPROPRIATE SIZES. MINIMUM GARAGE PARKING LANDSCAPING
MAINS WATER PRESSURE
IF MAINS WATER PRESSURE EXCEEDS OR MAY
359° 58' 20" 34000
EXISTING TO UNIT 2
EXCEED 500KPA, A PRESSURE LIMITING DEVICE IS
MINIMUM
INSTALLED TO ENSURE THAT THE MAX OPERATING EXISTING BOUNDARY FENCE
2000
PRESSURE AT ANY OUTLET WITHIN THE BOUNDARIES EXCLUSIVE USE 2A
3298
OF THE PROPERTY DOES NOT EXCEED 500KPA. BUP10978 APPROXIMATE LOCATION OF SEWER MAIN (TBC)
PROPOSED VISITOR 2
EXISTING BOUNDARY FENCE
EXISTING GARAGE 2
STRUCTURAL
LANDSCAPING
PROPOSED NEW
RETAINED
1. STRUCTURAL TIMBER LANDSCAPING AREAS
ALL STRUCTURAL TIMBER TO BE STRESS GRADE F14
UNLESS OTHERWISE NOTED.
ALL FRAMING TO COMPLY WITH AS 1684.2
PARKEDGE ROAD
2. STEEL WORK: 6000
ALL EXPOSED STEEL TO BE PRIMED AND PAINTED.
ALL WELDS TO BE 6.0MM CONTINUOUS FILLETS.
EXISTING UNIT 2 MINIMUM
INTERNAL LININGS
1. 10MM PLASTERBOARD U.N.O.
2. 6MM VILLABOARD TO WET AREAS U.N.O.
269° 58' 20" 19000
89° 58' 20" 19000
APPROXIMATE LOCATION OF SEWER MAIN (TBC)
IF IN DOUBT ASK!
6600
4000
SURVEY SYMBOL LEGEND EXISTING COMMON PROPERTY
CONCRETE DRIVEWAY BUP10978
LIGHT POLE FENCE
ROCK RETAINING WALL
OP ORIGINAL PEG
TIMBER RETAINING WALL
TBM TEMPORARY BENCH MARK
S STORM WATER PIPE
POWER POLE
G GAS SUPPLY
F FIRE HYDRANT
EXISTING BOUNDARY FENCE
BARRIER KERB LINE
A AIR VALVE
SEWER MANHOLE SURVEY CONTROL MARK
R ROOFWATER PIT S STORMWATER MANHOLE
PERMANENT SURVEY MARK
EXISTING UNIT 1
POWER BOX
EXISTING GARAGE 1
EXISTING VISITOR 1
TELSTRA PIT GULLY GRATE
CROSS-OVER WATER TAP/WATER/VALVE
HEADWALL SIGN (AS SHOWN)
S SEWER LINE EXISTING
SW STORMWATER LINE
TOP Top of Bank
TOE Bottom of Bank ELECTRIC POWER LINE
LANDSCAPING
EXCLUSIVE USE 1A
BUP10978
EXISTING BOUNDARY FENCE
179° 58' 20" 34000
PROPOSED FLOOR AREAS
U1 LOWER EXISTING 54.2 m²
U2 LOWER EXISTING 54.2 m²
U1 PORCH 7.0 m²
U2 PORCH 7.0 m²
U1 PATIO 4.7 m²
U2 PATIO ALTERATION 4.7 m²
U1 PERGOLA 4.8 m²
U2 LOWER ADDITION 12.9 m²
U1 GARAGE EXISTING 19.1 m²
NOOSA COUNCIL U2 GARAGE EXISTING 19.1 m²
U2 GARAGE ADDITION 14.8 m²
APPROVED PLAN U1 UPPER EXISTING 55.6 m²
51988.2740.02 10 NOV 2023 U2 UPPER EXISTING
U1 UPPER DECK
55.6 m²
7.0 m²
U2 UPPER DECK 7.0 m²
ISSUE DESCRIPTION DATE DESIGN KJ CHECKED KJ
A PRELIMINARY DRAWINGS 28.02.23
CLIENT PROJECT FLOOR AREAS:
B REVISION 1 12.04.23 W. & A. JACKSON PROPOSED ALTERATIONS KIERON JAMES DESIGN DRAWN
SCALE
KJ ISSUE
SHEET
D
C MCU APPROVAL 20.04.23 BUILDING DESIGN & DRAFTING
D REVISION 2 07.08.23
UNIT 2 / 21 - LOT 311 PH: 0417 633 275 1:200 A3 5 OF 10
JOB NUMBER DATE
DRAWING TITLE PARKEDGE ROAD P.O. BOX 483 COOLUM BEACH QLD 4573 23-009 07.08.2023
EMAIL: [email protected]
© COPYRIGHT - THIS DRAWING REMAINS THE PROPERTY OF KIERON JAMES DESIGN
PROPOSED SITE PLAN 1 : 200 SUNSHINE BEACH MEMBER BDAQ : QBCC LICENCE No. 81726 AND IS PROVIDED FOR THE USE AS DESCRIBED & MAY NOT BE USED
OR REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION.
Document Set ID: 22540760
Version: 1, Version Date: 14/08/2023
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Compiled Approved Plan - 51988 2740.02.pdfRelated documentApplication case desk ↗
About this file
- File size
- 21.6 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.