Council archive · source document
RFI - Attachment 7 - Response to Sustainable Building Design Code · MCU22/0094
COMPLIANCE
PERFORMANCE OUTCOME ACCEPTABLE OUTCOME RESPONSE
ü/û/NA
(i) The building orientation ensures that windows
and doors maximise prevailing winds and create
cross ventilation.
(ii) Solar panels and whirly birds are provided on
the roof, taking advantage of the characteristics
of the sub-tropical climate.
(iii) Vegetation is positioned in and around the site
to create evolving shade and light.
(iv) Awnings have been strategically placed to filter
sunlight.
For further details, please refer to Attachment 1 of the
Information Request Response material - amended
Architectural Plans.
Building design AO8.1 Complies with PO8
PO8 Development provides a detailed assessment The proposed development has been designed and sited with
Development - including supporting documents, demonstrating consideration taken to the sub-tropical environment and
(a) orientates buildings and windows to the means by which the design meets PO8. Schedule 6 – Sustainable Building Design of the Noosa Plan
make the most of prevailing winds, 2020. The following aspects have been considered as part of
natural ventilation and cross breezes; the building design to ensure that the development
(b) maximises shade to east and west walls; ü minimises reliance on unsustainable energy sources and can
(c) contains an open and permeable built appropriately respond to the sub-tropical climate of Noosa:
form that connects indoor and outdoor (i) Architectural elements and building features
spaces in an integrated design; such as awnings, operable window and door
(d) retains existing vegetation and natural positioning, balustrading, and screening.
shading where possible; (ii) Renewable energy methods such as rainwater
(e) incorporates passive building design to tank and solar panels.
See the original