Council archive · source document
Response to Action Notice - Set of plans · MCU25/0119
Plans and drawings: the text below has words only, no drawings.
Development Application
Rev. Date Description Iss. Appr.
A 24.01.22 PRELIMINARY PW PW
31543 B 15.02.22 WIP DA LAYOUT PW PW
C 23.02.22 WIP LAYOUT PW PW
D 24.02.22 WIP LAYOUT PW PW
E 01.03.22 WIP LAYOUT PW PW
UP F 02.03.22 WIP LAYOUT PW PW
G 08.03.22 WIP ELEVATIONS PW PW
2 PLANT/RAIN WATER TANK 3 H 08.03.22 WIP ELEVATION PW PW
3000
I 09.03.22 WIP DA PW PW
2000 (RAISED ABOVE OVERLAND FLOW PATH) 2000 J 11.03.22 DEVELOPMENT APPLICATION PW PW
K 14.03.22 DEVELOPMENT APPLICATION PW PW
L 15.03.22 DEVELOPMENT APPLICATION PW PW
M 15.03.22 DEVELOPMENT APPLICATION PW PW
N 16.03.22 DEVELOPMENT APPLICATION PW PW
O 11.05.22 DA RFI PW PW
P 18.05.22 DA RFI PW PW
Q 09.11.22 AMENDED DA PE PE
R 01.12.22 AMENDED DA PE PE
S 02.03.23 90% DESIGN ISSUE PE PW
T 05.11.24 DA Amendment PW PW
U 19.11.24 DA Amendment PW PW
1 4 BICYCLES
RAMP 1:5 RAMP 1:10 TO BASEMENT 01 REFUSE
2000
9842
TO L
UP
STAIR 3
E
Do not scale this drawing. Verify all dimensions on site before commencing
EASEMENT AB
VEL
any work. Copyright © 2023 Buchan. This drawing remains the property of
The Buchan Group Australia Pty Ltd. Reproduction in whole or in part without
FROM LEVEL 1 prior consent is forbidden.
1
SRV File
TRANSFORMER
3200
STAIR COUNT TO
BE CONFIRMED BASEMENT STAIR EGRESS AMBULANCE
UP
FROM BASEMENT
SERVICES
2600
LIFT 2
8568
2600
EQUIPMENT
HATCH TBC 5400 6477 5400
4 BICYCLES
7 BAYS + 1 AMBULANCE + SRV
INTEG
2600
RATE
D
3
SEAT
3000
ING A
2600
SBARR
IE
R TO
GROUND FLOOR TOTAL GFA:
EXISTING ACCESS AND CARPARKING
BIO-B
2600
ASIN
966m²
SSL 10.3m
1 0m ²
2400
BIO-B
NOTE: INTERTENANCY WALLS INDICATIVE ONLY
A
SIN
PWD
INTEG
2400
SHARED
RATE
ZONE
DSEAT
ING A
2400
Project
S
Lot 22 Medihub
BARR
IE
R TO
BIO-B
Noosa Business Centre
28 Eenie Creek Road
ASIN
Noosaville QLD
LIFT
23
Project Number
57 721072
STAIR 1
UP
TO LEVEL 01 Status
Date Plotted
19/11/2024 11:01:35 AM
Date Issued 19.11.24
FROM BASEMENT
Scale
4 BICYCLES INTEGRATED SEATING AS BARRIER TO BIO-BASIN
7566
0 1 2 4 6M
EASEMENT AB
Drawing Title
GROUND FLOOR
11493
10m² BIO-BASIN 4 BICYCLES
BOOSTER
7783
Drawing Number Revision
1000 U
1 GROUND FLOOR
2000 1 : 100 1
3000 Brisbane Studio
+ 61 7 3859 9222 / buchangroup.com.au
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Response to Action Notice - Set of plansRelated documentApplication case desk ↗
About this file
- File size
- 8.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.