Original source · versioned page text
Livable-Housing-Design-PCD-NCC-2022.pdf
Public Comment Draft
Livable Housing Design
Part 3 Internal doors and corridors
3.1 Clear opening width
Internal doors within the ground or entry level of the dwelling must provide a minimum clear opening width of 820 mm,
measured in accordance with Figure 2.1.
Applications
Clause 3.1 only applies to a doorway that connects to, or is in the path of travel to, any—
(a) habitable room; or
(b) attached Class 10a garage or carport that forms part of an access path required by Clause 1.1; or
(c) toilet complying with Parts 4 and 6; or
(d) bathroom complying with Parts 5 and 6.
3.2 Threshold
The threshold of an internal door that is subject to Clause 3.1 must—
(a) be level; or
T
(b) have a height not exceeding 5 mm if the lip is rounded or bevelled.
AF
3.3 Corridor width
Internal corridors, hallways, passageways or the like, if connected to a door that is subject to Clause 3.1, must have a
minimum clear width of 1000 mm, measured between the finished surfaces of opposing walls.
DR
Information
Skirting boards and the like may be disregarded for the purposes of compliance with Clause 3.3.
Page 11
[OCR of page images]
Public Comment Draft
Livable Housing Design
31 Clear opening width
Internal doors within the ground or entry level of the dwelling must provide a minimum clear opening width of 820 mm,
measured in accordance with Figure 2.1.
Applications
Clause 3.1 only applies to a doorway that connects to, or is in the path of travel to, any—
(a) habitable room; or
(b) attached Class 10a garage or carport that forms part of an access path required by Clause 1.1; or
(c) toilet complying with Parts 4 and 6; or
(d) bathroom complying with Parts 5 and 6.
3.2 Threshold
The threshold of an internal door that is subject to Clause 3.1 musi#—
(a) be level; or
(b) have a height not exceeding 5 mm if the lip is rounded or bevelled.
3.3 Corridor width
Internal corridors, hallways, passageways or the likemif connected to a door that is subject to Clause 3.1, must have a
minimum clear width of 1000 mm, measured between the finished surfaces of opposing walls.
Information te
Skirting boards and the like may be disre: led forthe purposes of compliance with Clause 3.3.