Skip to the record
Accept no imitations.

Council archive · source document

Approved Plan - MCU26 0012 & OPW26 0034 (As Published) · MCU26/0012

of 17

Check the original when the exact wording matters.

Plans and drawings: the text below has words only, no drawings.

Very large file (15.2 MB): may take a few minutes to open.

Log in to see the plans as drawn

Original PDF page 15, section 1. The text section number identifies this passage in the reader.

 

DRAWING SIZE — At

 

HEIGHT DATUM

LOT 2 ON RP 214048
Level Datum AHD
Lukes Road, Cooroy Mountain

Survey information provided by
MAX WATTERSON & ASSOCIATES (MWA)

=

2

 

 

 

 

LEGEND

_---77 INDICATES PROPOSED SURFACE

oO

18077 CONTOURS AND LEVELS TO AHD.
4180 EXISTING SURFACE SPOT LEVELS.
5.0% > INDICATES FINISHED SURFACE GRADE
FA INDICATES DIRECTION OF FALL
TO FINISHED SPOON DRAINS.
RAMP. INDICATES DIRECTION OF RAMP UP OR
Ss _DOWN AS INDICATED
x [29740] INDICATES PROPOSED FINISHED
SURFACE LEVELS
_____ (7) DENOTES WET TOOLED JOINT TO TERRACE
SLAB, REFER TO DRG. OW4.5 DETAILS
TERRACE SLAB. REFER TO STRUCTURAL
DETAILS FOR THICKNESS AND

REINFORCING.

DRIVEWAY SLAB/PAVEMENT. REFER TO
NOTES AND DETAILS ON DRG. OW4.5 FOR
THICKNESS AND REINFORCING.

LANDSCAPING, REFER LANDSCAPE
ARCHITECT FOR DETAILS.

INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE

INDICATES EXISTING SEWER LINE

INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS

INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS

INDICATES STORMWATER DRAIN EXISTING
AS NOTED

INDICATES POSITION OF RETAINING WALL
TO STRUCTURAL ENGINEERS DETAIL.

 

 

 

www.dialbeforeyoudig.com.au

 

DIAL1100

BEFORE YOU DIG

 

 

419.14

g.1¥
+1

3.84
+"

31
+"

 

 

 

 

 

 

 

 

 

 

 

 

 

47.99

er?

 

 

 

 

 

 

418.6

8

0.03
+0

 

 

 

 

8.16
+"

 

 

 

 

 

 

 

 

a
2,
iN
116.603 —
2 a
% tes
aot 115262

0.05
+7

x

9.5!
+"

 
 

PROPOSED
ARENA

 

 

FFL

918
+"

 

119.200 *

 

 

 

 

 

 
 

417 ENN

ay

 

9.90
+"

  

\\e
+1"

> y 116.264 INTO EXISTING NEATLY,
a oS ao NO STEP

JOIN PROPOSED DRIVEWAY

5.53
+"

116.853

 

46.58

 

 

 

 

 

 

 

 
   
       

9.3!
+" |

~ PROPOSED

 

STABLES
FFL]
sont 119.050

 

 

 

 

0]

 

 

 

 

 

SITE PLAN — DRIVEWAY LEVELS PLAN PART 2

Scale 1: 250

ALL SERVICES SHOWN ON THIS PLAN INDICATIVE

ONLY CONTRACTOR TO LOCATE ALL SERVIC

ES

PRIOR TO COMMENCING WORKS ON SITE. ALL

SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY
RESPONSIBLE FOR THE SERVICE

CONTRACTOR TO TOPSOIL AND TURF ANY

DISTURBED OR DAMAGED AREAS OF THE ROAD
RESERVE ADJACENT THE CONSTRUCTION SITE

 

ALL LINE MARKING TO BE IN ACCORDANCE
WITH THE QUEENSLAND MANUAL OF UNIFORM
TRAFFIC CONTROL DEVICES & A.S 2890.1

PARKING FACILITIES PART 1: OFF-STREET CAR

PARKING

CONTRACTOR TO REPAIR/REINSTATE ANY

DAMAGED AREAS OF EXISTING FOOTPATHS,
KERB & CHANNELS TO COUNCIL STANDARDS

44.39
+!

3.90
+"

5.23
4.98
+1"

 

 

 

 

+

 
  

 

  
 
 
 
  

 

 

 

 

 

 
 

 

 

 

 
 

 

 

 

 

42
334 +0

442.98

4.43
+"

5.45
+"

6.84
+"

32
+t"?

41290
412.89

41

49.28

pio

4
48.1
+!

412.30
ie"
+
2.68
ist 412.38
+
+
443.02
+
8
413.8!
2
418.0
+
+57
+ 4p 1108
18" 4 1108

KEY

EX. SWPT EXISTING STORMWATER PIT
EX. SWMH EXISTING STORMWATER MANHOLE

EX. SMH EXISTING SEWER MANHOLE

EX. SCP EXISTING SEWER CONNECTION POINT
E.0.B. EXISTING EDGE OF BITUMEN

K&C EXISTING KERB & CHANNEL

N.S.L. NATURAL SURFACE LEVEL

FH. FIRE HYDRANT

TP TELSTRA PIT

EP. ELECTRICAL PILLAR

KERB EXISTING KERBING

RCEW REINFORCED CONCRETE END WALL

S.V STOP VALVE

W.M WATER METER
41
+
4
412.3
+
412.26
+
3,20
+" ,
4
+
413.17
$1158
+
ane
418.60
ao

 

 

 

 

 

  
 
 
 
 

 
 
   
 

 
 
 
 
  
 

 

 

 

 

MAXIMUM CROSS-FALL OF 1 in 40 ON ALL
FOOT-PATHS AND INTERNAL PEDESTRIAN
PATHS AND RAMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

— Rife 2
fps TOCHIPON SOQ CCR Oa 959 /, RESIDENTIAL

j TOP 7777, a 7 DEVEL

(7 y 77 a i EMENT
+t 19.82 ° co f 4 A xX L
Laine [| — )f Fr Ty [ ~4,09 ood) —
PEELE IM22.000 ae La} et
ELLA

 
 
  

 

 

 

LLL

2.26
+0

 

 

 

122.C

 

 

 

 

 

 

 

 

 

 
  

 
  
 
 
 

 

 

 

 

 

 

 

 

\.
SS

 

 

 

 

 

 

 

 

 

Revision | Description Date

 

 

“FOR APPROVAL

 

DO NOT SCALE FROM THIS DRAWING

The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.

 

Unit 1/11 Project Ave,
Noosa Heads

Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com

O SCG

ABN 68 669 675 790

SCG HOLDINGS PTY LTD T/

 

 

 

 

 

 

 

 

DRIVEWAY LEVELS PLAN
PART 2
APPROVED PLAN 111 LUKES RD,
MCU26/0012 & OPW26/0034 COOROY MOUNTAIN
25 MAY 2026 :
Pate: Feb 2026 iRS TH
+P" pz @ a freon 0577 -OW4.2

 

 

 

Used in these records

About this file

File size
15.2 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Approved Plan - MCU26 0012 & OPW26 0034 (As Published).pdf · 15.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.