Original source · versioned page text
Appendix C - House Design Plans
Attached to the e-mail RAL21 0009 - Response to Info Request - House design plans - Gould Email 2 of 2.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn DANYA COOK TOWN PLANNING
Appendix C
House Design Plans
Prepared by Graham Green Design Drafting
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 21 pages
Page 2
PROPOSED RESIDENCE
FOR
B & M GOULD
AT
PROPOSED LOT 401 HAY STREET, TEWANTIN, QLD
3D VIEW FOR ILLUSTRATION PURPOSES ONLY
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
TITLE
RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-087 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] Mob 0438786080 LOT 401 HAY STREET,
0414801241
www.littledigs.com.au
DESIGN DRAFTING
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] N.T.S JUN.2021 TEWANTIN, QLD B & M GOULD 1 OF
Page 3
NORTH
HAY STREET
(46.410)
4500
5314
EASEMENT FOR ACCESS AND SERVICES
814
EASEMENT FOR ACCESS AND SERVICES
6000
OMP
PROPOSED
RESIDENCE
(22.980)
(22.980)
CAPORT FFL: 2.80m
EXISTING SEWER
LOWER FFL: 3.20m
UPPER FFL: 6.20m
UP
PROPOSED
OMP
2100
(46.410)
SWIMMING POOL
4500 13266 (PARTIAL ABOVE
GROUND)
CARPORT UNDER
RPD TWO STOREY BUILDING
LOT 401 on .....
AREA = 1066m2
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE.
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
SITE PLAN
SCALE 1:200
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
SITE PLAN RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-087 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] Mob 0438786080 LOT 401 HAY STREET,
0414801241
www.littledigs.com.au
DESIGN DRAFTING
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] 1:200 (A3) JUN.2021 TEWANTIN, QLD B & M GOULD 2 OF
Page 4
2
SHEET 08
20820
6180 5970 1750 6920
90 70 70
NORTH 6180 5970 90 1660 900 1500 530 70 3600 90
6180 5970 90 600 1150 1000 5740 90
24.09 DH OBS 09.18 SW XO
90
90
90
90
90
90
dp
900
900
70
24.06 LVR/24.15 FG/24.06 LVR
2465
BN
WC
5070
4980
4980
3200
3060
5000
ROBE
70
MASTER
BEDROOM 1
BN
2465
70
PROPOSED DEVELOPMENT PARAMETERS ENS
70900
1220 600 900
2700 CH
9750
GROUND FLOOR SHR
2.4x0.9
LIVING = 105 sqr.m. 820
90
90
70
70
70
2x dp
ALFRESCO = 19 sqr.m. REF
LANDING = 1 sqr.m.
CARPORT = 28 sqr.m.
24.09 LVR/ 24.15 FG
13740
13740
OVEN
UPPER FLOOR KITCHEN
4220
LIVING = 29 sqr.m.
LIVING
4500
4730
4750
TOTAL BUILDING AREA = 182 sqr.m.
bench
PAN
3000
SINK
ALL WINDOWS AND DOORS TO BE
FULLY FLY SCREENED.
NOTE: ALL GLAZING TO BE dp WM DW
8490
CONFIRMED BY MANUFACTURER 2x dp
1090 1080 600
1080 600
24.09 DH
900 90
T
900 70
90
AND BUILDER TO SUIT N3 WIND
LOADING. SIZES TO BE ADJUSTED
GATE
1 24.36 SGD XXO
TO SUIT WITH CONSENT FROM UP 2700 CH SWIMMING
THE OWNERS SHEET 08 POOL
90
24.36 SGD XXO
WINDOW &
90 1500 70 1200
1090
3890
3900
820
CARPORT UP
3670
DOOR LEGEND DINING ALFRESCO
90
2770
820
ALL WINDOWS & DOORS TO BE VERIFIED
DH OBS
3100 CH
24.09
AGAINST FLOOR PLANS AND ELEVATIONS
1835
1680
90 1500
BY CONTRACTOR. DISCREPANCIES ARE TO SINK
BE REPORTED TO THE DESIGNER PRIOR TO WC UP
COMMENCEMENT. BUILDERS TO CONFIRM
100
WITH OWNERS FINAL WINDOW SLIDING DIRECTIONS,
90
90
90
TYPE OF GLAZING, AND COLOURS BEFORE dp
FINAL ORDERING AND INSTALLATION TO 09.24 SW XOX
ENABLE CHANGES.
SW - Sliding Window (OX - fixed/open) 8.0m MAX
SGD - Sliding Door (stacker noted) BUILDING HEIGHT 90 70
TBC BY BUILDER
DH - Double Hung DURING SETOUT
6180 4000 890 1010 650 1100 1000 1750 90 3900 90
FG - Fixed Glass
LVR - Louvre Window 6180 3500 90 2400 70 4500 90 3890 100
AW - Awning Window
LFL - Louvre/Fixed/Louvre Combo 6180 3500 1390 5760 3990 3500
BF - Bi-fold Door
CS - Cavity Slider 20820
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND DENOTES HARDWIRED SMOKE DETECTOR/ALARM
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS INSTALLED TO NCC REQUIREMENTS
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE.
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT PROPOSED GROUND FLOOR PLAN
AUSTRALIAN BUILDING CODE REQUIREMENTS NOTE: 2700mm HIGH CEILINGS. 2400mm HIGH JOINERY HEIGHT UNO
SCALE 1:100(A3)
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
GROUND FLOOR PLAN RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-087 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] DESIGN DRAFTING Mob 0438786080 LOT 401 HAY STREET,
0414801241
www.littledigs.com.au
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] 1:100 (A3) JUN.2021 TEWANTIN, QLD B & M GOULD 3 OF
Page 5
GENERAL NOTES:
NORTH
1. This structure has been designed in accordance with the
current editions of the Building Code of Australia (NCC-2021)
and the Queensland Building Act - Standard Building Law,
2. All building work shall comply with the current editions of
the relevant Australian and New Zealand Standards and other
documents as called up in the NCC-2021.
3. Unless stated otherwise, all materials shall be as listed in
the Accredited Building Products Register.
6180 4. The builder shall check and verify all dimensions, fixings,
fittings and finishes before commencement of works.
90 6000 90
90 2400 70 3530 90 5. Reduced levels (RL's) and ground contours as shown have
not been measured by the author of these documents and may
90
only indicate the approximate general shape of the terrain and
900 530 90
12.09 SW XO
heights of the various building elements. Unless stated other-
510
90
ROBE DESK
wise, actual accurate levels shall be determined either by the
builder or a land surveyor prior to commencement.
90
70
OBS 24.09 DH
1
900
820
SHEET 08
770
6. Written dimensions as show on the drawings take pre-
cedence. DO NOT SCALE DIRECT FROM THE DRAWINGS!. In the
4450
4270
70
09.06
AWN
WC 24.09 DH
event that questions arise, discrepancies or errors are
90
BEDROOM 2
09.24 SW XOX
noticed, please do not proceed with the work without
2700
2770
ENS
BN
2700 CH requesting further instructions from the builder and/or the
building designer.
SHR
1.5x0.9 7. Construction must not vary from these drawings without
90
90
24.09 DH the written approval of the owner/s, licensed certifier and
the building designer.
90 1500 70 4430 90
8, Unless stated otherwise, these drawings have been prep-
6180 ared either for client approval, planning approval or building
WINDOW & permit approval only. No responsibilty will be accepted by
DOOR LEGEND the building designer for drawings or further construction (shop)
ALL WINDOWS & DOORS TO BE VERIFIED
AGAINST FLOOR PLANS AND ELEVATIONS
drawings prepared by others.
BY CONTRACTOR. DISCREPANCIES ARE TO
BE REPORTED TO THE DESIGNER PRIOR TO
COMMENCEMENT. BUILDERS TO CONFIRM 9. Any anchor rods/bolts and roof truss tie-down details
WITH OWNERS FINAL WINDOW SLIDING DIRECTIONS, shown are for standard trusses only. The builder shall obtain
TYPE OF GLAZING, AND COLOURS BEFORE
FINAL ORDERING AND INSTALLATION TO tie-down details for any non-standard trusses such as hips,
ENABLE CHANGES. girders, valleys etc. from the truss manufacturer or struct-
SW - Sliding Window (OX - fixed/open) ural engineer. This information shall be made available to
SGD - Sliding Door (stacker noted) the Local Government or Licensed Certifier at the time of
DH - Double Hung lodgement of the Building Permit Application.
FG - Fixed Glass
LVR - Louvre Window
AW - Awning Window
PROPOSED UPPER FLOOR PLAN 10. Refer to the structural and/or geochemical engineering
LFL - Louvre/Fixed/Louvre Combo SCALE 1:100(A3) report/s for footings and slab details not shown.
BF - Bi-fold Door
DENOTES HARDWIRED SMOKE DETECTOR/ALARM
CS - Cavity Slider
INSTALLED TO NCC REQUIREMENTS
11. Unless stated otherwise, rainwater discharge either shall
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND be directed to the road kerb or dispersed within the prop-
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS erty boundaries to Local Government requirements.
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE. NOTE: 2700mm HIGH CEILINGS. 2400mm HIGH JOINERY HEIGHT UNO
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
UPPER FLOOR PLAN RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-087 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] DESIGN DRAFTING Mob 0438786080 LOT 401 HAY STREET,
0414801241
www.littledigs.com.au
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] 1:100 (A3) JUN.2021 TEWANTIN, QLD B & M GOULD 4 OF
Page 6
2
NORTH SHEET 08
2419
2535
2733
2419
2535
2733
2419
2865
2733
2419
2865
2733
1
1989
SHEET 08
SUB-FLOOR OPEN
4450
CARPORT ON HARDSTAND
SLAB ON GROUND
2865
2733
1989
UP
3053 3053
6180
PROPOSED SUB-FLOOR PLAN
SCALE 1:100(A3)
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE.
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
STUDIO FLOOR PLANS RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-087 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] Mob 0438786080 LOT 401 HAY STREET,
0414801241
www.littledigs.com.au
DESIGN DRAFTING
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] 1:100 (A3) JUN.2021 TEWANTIN, QLD B & M GOULD 5 OF
Page 7
FC COVER STRIP BATTENS AT 450 SPACES
UPPER CH
COLORBOND CUSTOMORB ROOF SHEETING
8.0m MAX BUILDING HEIGHT
WITH R3.5 INSULATION
G REE
PITCH 8900
12 DE
UPPER
GFL CH
6200
5900
GFL
CARPORT
3200
2800
75x4 SHS POSTS TO SUBFLOOR & CARPORT
NORTH ELEVATION
SCALE 1:100(A3)
WINDOW HEAD CLEARANCE
TBC BY BUILDER FC COVER STRIP BATTENS AT 450 SPACES WEATHERTEX WEATHERGROOVE
150 NATURAL CLADDING
UPPER CH
8900
UPPER
GFL CH
6200
5900
GFL
CARPORT
3200
2800
WEATHERTEX WEATHERGROOVE 100 SQR HWD POST STAIRS AND HANDRAILS TO NCC REQUIREMENTS
SOUTH ELEVATION
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS 150 NATURAL CLADDING TO ALFRESCO
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE. SCALE 1:100(A3)
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
ELEVATIONS RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-087 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] Mob 0438786080 LOT 401 HAY STREET,
0414801241
www.littledigs.com.au
DESIGN DRAFTING
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] 1:100 (A3) JUN.2021 TEWANTIN, QLD B & M GOULD 6 OF
Page 8
UPPER CH
8900 11.5 DEGREE COLORBOND
CUSTOMORB ROOF
UPPER
6200
GFL CH
5900
GFL FC SHEET CLADDING
450 COVER STRIPS
3200
75x4 SHS POSTS TO SUBFLOOR
EASTSCALE
ELEVATION
1:100(A3)
UPPER CH
8.0m MAX BUILDING HEIGHT
8900
UPPER
6200
GFL CH
5900
GFL
CARPORT
3200
2800
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS
WEST ELEVATION
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE. SCALE 1:100(A3)
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
SECTION RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-087 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] Mob 0438786080 LOT 401 HAY STREET,
0414801241
www.littledigs.com.au
DESIGN DRAFTING
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected]
1:100 (A3) JUN.2021 TEWANTIN, QLD B & M GOULD 7 OF
Page 9
RAKED CEILING TO
900 STAIRWELL
TYP
PREFABRICATED TIMBER ROOF TRUSSES AT 900 CENTERS (SHEET ROOF)
TO MANUFACTURERS DESIGN AND SPECIFICATIONS
UPPER CH
TBC DURING SETOUT BY BUILDER
8.0m MAX BUILDING HEIGHT
8900 11.5 D
EGRE
E PIT
CH SELECT COLORBOND CUSTOMORB ROOF SHEETING
2700
R3.5 INSULATION
2400
6000
UPPER
FLOOR FRAMING TO ENGINEERS DESIGN
GFL CH
6200
5900
900
TYP
2700
SELECT DECKING
3100
75x SHS POST TO
CONCRETE SLAB TO CARPORT
CARPORT
GFL
CARPORT FLOOR FRAMING TO ENGINEERS DESIGN
3200
2800
CLEARANCE TO TOP OF STAIRS
TBC TO SUIT FINAL RAFTER SIZES
Section 1
1 1 : 100
TERMITE PROTECTION
2100 PROVIDE TERMITE PROTECTION IN ACCORDANCE WITH AS 3660.01 - 2000
USING LICENSED CONTRACTOR. INSTALL A "PHYSICAL BARRIER" TO
PERIMETER OF SLAB & TO ALL PENETRATIONS & PART B SPRAY IN
ACCORDANCE WITH AMENDMENT 8 OF BCA.
GFL CH
ATTACHMENTS TO BUILDINGS: ATTACHMENTS TO BUILDING, SUCH AS
900 900
5900 DOWNPIPES AND SERVICE PIPES SHALL HAVE A NOMINAL GAP, TO ALLOW
TYP TYP CLEAR AND UNINTERRUPTED INSPECTION ACROSS THE INSPECTION ZONE.
2700
STRUCTURES SUCH AS STEPS, VERANDAHS, PORCHES, ACCESS RAMPS,
CARPORTS, TRELLISES, DECKS, HOT WATER SYSTEMS, AIR CONDITIONERS,
OR SIMILAR, WHICH ARE NOT PROVIDED WITH ONE OF THE BARRIER
GFL SYSTEMS DESCRIBED IN THE
FLOOR FRAMING TO ENGINEERS DESIGN AS 3660.1-200, SHALL BE SEPARATED FROM THE BUILDING BY A GAP OF AT
3200 LEAST 25mm, TO ALLOW CLEAR AND UNINTERRUPTED VISUAL INSPECTION
ACROSS THE INSPECTION ZONE.
WHERE ATTACHMENTS OR STRUCTURES, AS OUTLINED ABOVE, ABUT A
BUILDING AND THERE IS NO CLEAR GAP, THEN A BARRIER SHALL BE
75x4 SHS POSTS TO SUBFLOOR PROVIDED TO THE ATTACHMENT, REGARDLESS OF THE SIZE OF THE
Section 2 ATTACHMENT.
2 1 : 100
BRIDGING AND BREACHING.
BARRIERS SHALL NOT BE BRIDGED BY STRUCTURES, FIXTURES OR FITTINGS
ATTACHED TO THE MAIN BUILDING ( E.G. HOT-WATER SYSTEMS, STEPS,
VERANDAHS ACCESS RAMPS CLADDINGS, CARPORTS, TRELLISES OR
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS SIMILAR STRUCTURES), NOR SHALL THEY BE BREACHED BY THE
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE. INSTALLATION OF SERVICE ENTRY POINTS, DOWN PIPES, AN ADDITIONAL
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT SLAB, PATHWAYS, LANDSCAPING, GARDENING, OR SIMILAR, UNLESS
AUSTRALIAN BUILDING CODE REQUIREMENTS ADDITIONAL BARRIERS ARE USED TO DETER CONCEALED ACCESS BY
AND RELEVANT AUSTRALIAN STANDARDS. TERMITES TO THE STRUCTURE.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
SECTIONS RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-087 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] DESIGN DRAFTING Mob 0438786080 LOT 401 HAY STREET,
0414801241
www.littledigs.com.au
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] 1:100 (A3) JUN.2021 TEWANTIN, QLD B & M GOULD 8 OF
Page 10
NORTH
dp
11.5°
2x dp
dp
2x dp
11.5°
11.5°
dp
PROPOSED ROOF PLAN
SCALE 1:100(A3)
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE.
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
ROOF PLAN RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-087 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] Mob 0438786080 LOT 401 HAY STREET,
0414801241
www.littledigs.com.au
DESIGN DRAFTING
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] 1:100 (A3) JUN.2021 TEWANTIN, QLD B & M GOULD 9 OF
Page 11
ELECTRICAL SYMBOL KEY
SYMBOL DESCRIPTION NO.
SUB BOARD
EXTERNAL LIGHT
WALL LIGHT
NORTH
DOWN LIGHT 12V
ENERGY EFFICIENT DOWN LIGHT
TV T.V. POINT x4 CO-AXIAL CABLE
E ETHERNET
PH PHONE POINT
x;x SINGLE GP0 (ARROW INDICATES
▼ POSITION)
x;xx DOUBLE GPO (ARROW INDICATES
▼ POSITION)
SINGLE FLOURO
DOUBLE FLOURO
HEAT LAMP / EXHAUST FAN
SPOT LIGHT
CEILING FAN
MV MECHANICAL VENT.
BCA PART 3.8.5
DW DISHWASHER
RH RANGEHOOD POINT
MW MICROWAVE POINT
SPA SPA BATH POINT
SA SMOKE ALARM - AS 3760
SWITCH
FL FEATURE LIGHT
PL PELMET LIGHT
UP HTR HEATED TOWEL RAIL-HARDWIRED
DL DECK LIGHT
UP
UW UNDERWATER POOL LIGHT
SLED STRIP LED
2 way 2 WAY SWITCHING
SIDE REGISTER NO 1
SR 1 D/A
A/C UNIT A
CEILING REGISTER NO
CR 1 D/A 1 A/C UNIT A
VRV A VRV A/C UNIT A
SINGLE GP0 UNDER
x;ux BENCH (ARROW INDICATES
▼ POSITION)
WALL MOUNTED DOWN
x;WD LIGHT (ARROW INDICATES
▼
PROPOSED ELECTRICAL PLAN
POSITION)
MCS MASTER CONTROL SWITCH
SCALE 1:100(A3)
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE.
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
ELECTRICAL PLAN RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-087 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] DESIGN DRAFTING Mob 0438786080 LOT 401 HAY STREET,
0414801241
www.littledigs.com.au
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected]
1:100 (A3) JUN.2021 TEWANTIN, QLD B & M GOULD 10 OF
Page 12
ELECTRICAL SYMBOL KEY
SYMBOL DESCRIPTION NO.
SUB BOARD
EXTERNAL LIGHT
WALL LIGHT
NORTH DOWN LIGHT 12V
ENERGY EFFICIENT DOWN LIGHT
TV T.V. POINT x4 CO-AXIAL CABLE
E ETHERNET
PH PHONE POINT
x;x SINGLE GP0 (ARROW INDICATES
▼ POSITION)
x;xx DOUBLE GPO (ARROW INDICATES
▼ POSITION)
SINGLE FLOURO
DOUBLE FLOURO
HEAT LAMP / EXHAUST FAN
SPOT LIGHT
CEILING FAN
MV MECHANICAL VENT.
BCA PART 3.8.5
DESK
DW DISHWASHER
RH RANGEHOOD POINT
MW MICROWAVE POINT
SPA SPA BATH POINT
ENS
SA SMOKE ALARM - AS 3760
SWITCH
FL FEATURE LIGHT
PL PELMET LIGHT
HTR HEATED TOWEL RAIL-HARDWIRED
DL DECK LIGHT
UW UNDERWATER POOL LIGHT
SLED STRIP LED
2 way 2 WAY SWITCHING
SIDE REGISTER NO 1
SR 1 D/A
A/C UNIT A
CEILING REGISTER NO
CR 1 D/A 1 A/C UNIT A
VRV A VRV A/C UNIT A
SINGLE GP0 UNDER
x;ux BENCH (ARROW INDICATES
PROPOSED UPPER ELECTRICAL PLAN ▼
x;WD
▼
POSITION)
WALL MOUNTED DOWN
LIGHT (ARROW INDICATES
POSITION)
SCALE 1:100(A3)
MCS MASTER CONTROL SWITCH
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE.
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
ELECTRICAL PLAN RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-087 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] DESIGN DRAFTING Mob 0438786080 LOT 401 HAY STREET,
0414801241
www.littledigs.com.au
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected]
1:100 (A3) JUN.2021 TEWANTIN, QLD B & M GOULD 11 OF
Page 13
PROPOSED RESIDENCE
FOR
K GOULD
AT
PROPOSED LOT 402 HAY STREET, TEWANTIN, QLD
3D VIEW FOR ILLUSTRATION PURPOSES ONLY
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
TITLE
RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-088 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] Mob 0438786080 LOT 402 HAY STREET,
0414801241
www.littledigs.com.au
DESIGN DRAFTING
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] N.T.S JUN.2021 TEWANTIN, QLD K GOULD 1 OF
Page 14
NORTH
EASEMENT ACCESS
TO HAY ST
(46.410)
4500
3315
4253
EASEMENT FOR ACCESS AND SERVICES
18.44
18.44
6000
6900
EXISTING SEWER
PROPOSED
427 RESIDENCE
ER
3
FFL: 2.90m TBC
EW
GS
TO SUIT Q100
STIN
UP 313
6
EXI
AND SUB-FLOOR
CLEARANCE REQ.
2425
1510
(46.410)
RPD
LOT 402 on .....
SITE PLAN
SCALE 1:200
AREA = 856m2
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE.
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
SITE PLAN RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-088 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] Mob 0438786080 LOT 402 HAY STREET,
0414801241
www.littledigs.com.au
DESIGN DRAFTING
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] 1:200 (A3) JUN.2021 TEWANTIN, QLD K GOULD 2 OF
Page 15
2
SHEET 07
21540
NORTH 1000 5760 2500 9180 3100
1000 5760 100 2400 90 9000 90 3000 100
70 70 70 70 70 70 70
1000 90 1600 70 1930 90 1760 800 900 1800 530 900 530 3600 90 2170 90 3000 100
24.24 DH 24.09 DH
90
90
90
dp
24.09 DH
1990
1990
1990
1900
UP UP
3700
dp LIVING
RA
RA
24.45 SGD XXXO
KE
2700 CH
KE
D
DC
6590
6500
CE
EIL
I LI
24.27 SGD XXO
ING
NG
PROPOSED DEVELOPMENT PARAMETERS
4600
4600
4600
900
4690
PORCH ALFRESCO
LIVING = 140 sqr.m. DW DINING
ALFRESCO = 15 sqr.m. SINK
90700 1200
PORCH = 12 sqr.m. KITCHEN
LANDING = 2 sqr.m.
11790
11790
OVEN
TOTAL BUILDING AREA = 169 sqr.m.
90
70 530 90
24.18 DH 09.18 SW XO dp 24.15 SGD OX PAN REF
70 530 1200 90
dp
7090090
820
820 CS
1165
ROBE
530 900
ALL WINDOWS AND DOORS TO BE 24.09 DH
820
720
LIN
FULLY FLY SCREENED. LNDRY
70 70
NOTE: ALL GLAZING TO BE 820
620
70
DESK
CONFIRMED BY MANUFACTURER
24.21 SGD OX
WM T LIN 2700 CH
AND BUILDER TO SUIT N3 WIND
1
P
2180
3130
LOADING. SIZES TO BE ADJUSTED
70 1500
BEDROOM 2 ENSUITE
24.30 DH
3080
5020
TO SUIT WITH CONSENT FROM SHEET 07
5110
ROBE
THE OWNERS WC MASTER
2700 CH BEDROOM 1
WINDOW &
3150
BN
STUDY
90 1200 90
820 CS
DOOR LEGEND
1880
DH OBS
1855
24.06
9090070
ALL WINDOWS & DOORS TO BE VERIFIED ENS BN
AGAINST FLOOR PLANS AND ELEVATIONS WC SHR
BY CONTRACTOR. DISCREPANCIES ARE TO SHR
1.2x1.2 1.5x1.88
BE REPORTED TO THE DESIGNER PRIOR TO
90
90
90
dp
COMMENCEMENT. BUILDERS TO CONFIRM
WITH OWNERS FINAL WINDOW SLIDING DIRECTIONS, 24.09 DH 24.09 DH 24.21 DH
24.24 DH OBS SAFETY
TYPE OF GLAZING, AND COLOURS BEFORE OBS
FINAL ORDERING AND INSTALLATION TO
ENABLE CHANGES. 90
1000 3600 90 3600 70 1500 70 1800 70 530 70 3600 90 2260 3100
SW - Sliding Window (OX - fixed/open)
SGD - Sliding Door (stacker noted) 1000 15180 2260 3100
DH - Double Hung
FG - Fixed Glass 21540
LVR - Louvre Window
AW - Awning Window
LFL - Louvre/Fixed/Louvre Combo
BF - Bi-fold Door
CS - Cavity Slider DENOTES HARDWIRED SMOKE DETECTOR/ALARM
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND PROPOSED FLOOR PLAN INSTALLED TO NCC REQUIREMENTS
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS
SCALE 1:100(A3)
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE.
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
CEILING HEIGHT 2700mm HIGH WITH ALL JOINERY AND DOORS/WINDOWS 2400mm HIGH
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
FLOOR PLAN RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-088 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] DESIGN DRAFTING Mob 0438786080 LOT 402 HAY STREET,
0414801241
www.littledigs.com.au
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] 1:100 (A3) JUN.2021 TEWANTIN, QLD K GOULD 3 OF
Page 16
GENERAL NOTES:
NORTH 1. This structure has been designed in accordance with the
current editions of the Building Code of Australia (NCC-2021)
and the Queensland Building Act - Standard Building Law,
2. All building work shall comply with the current editions of
the relevant Australian and New Zealand Standards and other
2
documents as called up in the NCC-2021.
SHEET 07
3. Unless stated otherwise, all materials shall be as listed in
the Accredited Building Products Register.
4. The builder shall check and verify all dimensions, fixings,
fittings and finishes before commencement of works.
5. Reduced levels (RL's) and ground contours as shown have
not been measured by the author of these documents and may
only indicate the approximate general shape of the terrain and
heights of the various building elements. Unless stated other-
wise, actual accurate levels shall be determined either by the
builder or a land surveyor prior to commencement.
6. Written dimensions as show on the drawings take pre-
cedence. DO NOT SCALE DIRECT FROM THE DRAWINGS!. In the
event that questions arise, discrepancies or errors are
noticed, please do not proceed with the work without
requesting further instructions from the builder and/or the
building designer.
7. Construction must not vary from these drawings without
the written approval of the owner/s, licensed certifier and
the building designer.
1
SHEET 07 8, Unless stated otherwise, these drawings have been prep-
ared either for client approval, planning approval or building
permit approval only. No responsibilty will be accepted by
the building designer for drawings or further construction (shop)
drawings prepared by others.
9. Any anchor rods/bolts and roof truss tie-down details
shown are for standard trusses only. The builder shall obtain
tie-down details for any non-standard trusses such as hips,
girders, valleys etc. from the truss manufacturer or struct-
ural engineer. This information shall be made available to
the Local Government or Licensed Certifier at the time of
lodgement of the Building Permit Application.
10. Refer to the structural and/or geochemical engineering
report/s for footings and slab details not shown.
PROPOSED SUB-FLOOR PLAN 11. Unless stated otherwise, rainwater discharge either shall
SCALE 1:100(A3) be directed to the road kerb or dispersed within the prop-
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS erty boundaries to Local Government requirements.
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE.
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
SUB FLOOR PLAN RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-088 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] Mob 0438786080 LOT 402 HAY STREET,
0414801241
www.littledigs.com.au
DESIGN DRAFTING
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] 1:100 (A3) JUN.2021 TEWANTIN, QLD K GOULD 4 OF
Page 17
3 DEGREE PITCH CO
LORBOND TRIMDEK
GFL CH
5600
GFL
2900
HARDIES LINEA EXTERNAL CLADDING
WITH FC COVERSTRIP
HARDIES AXON 133 EXTERNAL CLADDING
NORTH ELEVATION
SCALE 1:100(A3)
COLORBOND TRIMDEK ROOF SHEETING
WITH R3.5 INSULATION
3 DEG ROOF PITCH
GFL CH
5600
100 SQR HWD POST
TO ALFRESCO
GFL
2900
HARDIES LINEA CLADDING WITH SELECT DECKING
FC COVERSTRIP AT 450 CENTERS
75x4 SHS POSTS TO SUBFLOOR
SOUTH ELEVATION
SCALE 1:100(A3)
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE.
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
ELEVATIONS RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-088 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] Mob 0438786080 LOT 402 HAY STREET,
0414801241
www.littledigs.com.au
DESIGN DRAFTING
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] 1:100 (A3) JUN.2021 TEWANTIN, QLD K GOULD 5 OF
Page 18
FC SHEET CLADDING
450 COVER STRIPS
BOUNDARY
GFL CH
5600
GFL
2900
75x4 SHS POSTS TO SUBFLOOR
EASTSCALE
ELEVATION
1:100(A3)
BOUNDARY
3 DEGREE COLORBOND
TRIMDECK ROOF SHEETING
GFL CH
5600
GFL
2900
WEST ELEVATION HARDIES LINEA CLADDING WITH
FC COVERSTRIP AT 450 CENTERS
HARDIES AXON 133 EXTERNAL CLADDING SCALE 1:100(A3)
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE.
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
ELEVATIONS RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-088 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] Mob 0438786080 LOT 402 HAY STREET,
0414801241
www.littledigs.com.au
DESIGN DRAFTING
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected]
1:100 (A3) JUN.2021 TEWANTIN, QLD K GOULD 6 OF
Page 19
CEILING HEIGHT 2700mm HIGH WITH ALL JOINERY AND DOORS/WINDOWS 2400mm HIGH
LORBOND TRIMDEK
3 DEGREE PITCH CO 900
900 TYP
GFL CH TYP
5600 900 100 SQR HWD POSTS TO DECK AND PORCH
TYP
2700
SELECT DECKING
GFL
FLOOR FRAMING TO ENGINEERS DESIGN
2900
SUBFLOOR CLEARANCE 75x4 SHS POSTS TO SUBFLOOR
TO NCC REQUIREMENTS
Section 1
1 1 : 100
TERMITE PROTECTION
PROVIDE TERMITE PROTECTION IN ACCORDANCE WITH AS 3660.01 - 2000
BOUNDARY
USING LICENSED CONTRACTOR. INSTALL A "PHYSICAL BARRIER" TO
SELECT COLORBOND TRIMDECK ROOF SHEETING PERIMETER OF SLAB & TO ALL PENETRATIONS & PART B SPRAY IN
PREFABRICATED TIMBER ROOF TRUSSES AT 900 CENTERS (TRIMDEK SHEET ROOF) R3.5 INSULATION
TO MANUFACTURERS DESIGN AND SPECIFICATIONS ACCORDANCE WITH AMENDMENT 8 OF BCA.
ATTACHMENTS TO BUILDINGS: ATTACHMENTS TO BUILDING, SUCH AS
DOWNPIPES AND SERVICE PIPES SHALL HAVE A NOMINAL GAP, TO ALLOW
900 900 1510
GFL CH TYP TYP
CLEAR AND UNINTERRUPTED INSPECTION ACROSS THE INSPECTION ZONE.
5600 STRUCTURES SUCH AS STEPS, VERANDAHS, PORCHES, ACCESS RAMPS,
CARPORTS, TRELLISES, DECKS, HOT WATER SYSTEMS, AIR CONDITIONERS,
2425 OR SIMILAR, WHICH ARE NOT PROVIDED WITH ONE OF THE BARRIER
2700
2400
SYSTEMS DESCRIBED IN THE
AS 3660.1-200, SHALL BE SEPARATED FROM THE BUILDING BY A GAP OF AT
LEAST 25mm, TO ALLOW CLEAR AND UNINTERRUPTED VISUAL INSPECTION
GFL ACROSS THE INSPECTION ZONE.
FLOOR FRAMING TO ENGINEERS DESIGN
2900 WHERE ATTACHMENTS OR STRUCTURES, AS OUTLINED ABOVE, ABUT A
BUILDING AND THERE IS NO CLEAR GAP, THEN A BARRIER SHALL BE
PROVIDED TO THE ATTACHMENT, REGARDLESS OF THE SIZE OF THE
75x4 SHS POST TO ATTACHMENT.
SUBFLOOR
SUBFLOOR CLEARANCE
TO NCC REQUIREMENTS BRIDGING AND BREACHING.
Section 2 BARRIERS SHALL NOT BE BRIDGED BY STRUCTURES, FIXTURES OR FITTINGS
2 1 : 100
ATTACHED TO THE MAIN BUILDING ( E.G. HOT-WATER SYSTEMS, STEPS,
VERANDAHS ACCESS RAMPS CLADDINGS, CARPORTS, TRELLISES OR
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND SIMILAR STRUCTURES), NOR SHALL THEY BE BREACHED BY THE
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS INSTALLATION OF SERVICE ENTRY POINTS, DOWN PIPES, AN ADDITIONAL
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE. SLAB, PATHWAYS, LANDSCAPING, GARDENING, OR SIMILAR, UNLESS
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT ADDITIONAL BARRIERS ARE USED TO DETER CONCEALED ACCESS BY
AUSTRALIAN BUILDING CODE REQUIREMENTS
TERMITES TO THE STRUCTURE.
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
SECTIONS RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-088 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] DESIGN DRAFTING Mob 0438786080 LOT 402 HAY STREET,
0414801241
www.littledigs.com.au
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] 1:100 (A3) JUN.2021 TEWANTIN, QLD K GOULD 7 OF
Page 20
NORTH
3°
3°
PROPOSED ROOF PLAN
SCALE 1:100(A3)
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE.
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
ROOF PLAN RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-088 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] Mob 0438786080 LOT 402 HAY STREET,
0414801241
www.littledigs.com.au
DESIGN DRAFTING
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] 1:100 (A3) JUN.2021 TEWANTIN, QLD K GOULD 8 OF
Page 21
ELECTRICAL SYMBOL KEY
SYMBOL DESCRIPTION NO.
SUB BOARD
EXTERNAL LIGHT
WALL LIGHT
NORTH
DOWN LIGHT 12V
ENERGY EFFICIENT DOWN LIGHT
TV T.V. POINT x4 CO-AXIAL CABLE
E ETHERNET
PH PHONE POINT
x;x SINGLE GP0 (ARROW INDICATES
▼ POSITION)
x;xx DOUBLE GPO (ARROW INDICATES
▼ POSITION)
SINGLE FLOURO
DOUBLE FLOURO
HEAT LAMP / EXHAUST FAN
SPOT LIGHT
CEILING FAN
MV MECHANICAL VENT.
BCA PART 3.8.5
DW DISHWASHER
RH RANGEHOOD POINT
MW MICROWAVE POINT
SPA SPA BATH POINT
SA SMOKE ALARM - AS 3760
SWITCH
UP FL FEATURE LIGHT
PL PELMET LIGHT
HTR HEATED TOWEL RAIL-HARDWIRED
DL DECK LIGHT
UW UNDERWATER POOL LIGHT
SLED STRIP LED
2 way 2 WAY SWITCHING
SIDE REGISTER NO 1
SR 1 D/A
A/C UNIT A
CEILING REGISTER NO
CR 1 D/A 1 A/C UNIT A
VRV A VRV A/C UNIT A
SINGLE GP0 UNDER
x;ux BENCH (ARROW INDICATES
▼ POSITION)
WALL MOUNTED DOWN
x;WD LIGHT (ARROW INDICATES
▼
PROPOSED ELECTRICAL PLAN
POSITION)
MCS MASTER CONTROL SWITCH
SCALE 1:100(A3)
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE.
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
ELECTRICAL PLAN RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-088 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] DESIGN DRAFTING Mob 0438786080 LOT 402 HAY STREET,
0414801241
www.littledigs.com.au
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected]
1:100 (A3) JUN.2021 TEWANTIN, QLD K GOULD 9 OF
Page 22
GFL
2900
KITCHEN VIEW A
SCALE 1:50(A3)
DW
SINK
A
KITCHEN B
GFL CH
OVEN
5600
PANTRY REF
KITCHEN PLAN
SCALE 1:50(A3)
GFL
2900
KITCHEN VIEW B
SCALE 1:50(A3)
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE.
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
KITCHEN PLAN RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-088 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] DESIGN DRAFTING Mob 0438786080 LOT 402 HAY STREET,
0414801241
www.littledigs.com.au
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected]
1:50 (A3) JUN.2021 TEWANTIN, QLD K GOULD 10 OF