Appendix C - House Design Plans
Attached to the e-mail RAL21 0009 - Response to Info Request - House design plans - Gould Email 2 of 2.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn GENERAL NOTES:
NORTH 1. This structure has been designed in accordance with the
current editions of the Building Code of Australia (NCC-2021)
and the Queensland Building Act - Standard Building Law,
2. All building work shall comply with the current editions of
the relevant Australian and New Zealand Standards and other
2
documents as called up in the NCC-2021.
SHEET 07
3. Unless stated otherwise, all materials shall be as listed in
the Accredited Building Products Register.
4. The builder shall check and verify all dimensions, fixings,
fittings and finishes before commencement of works.
5. Reduced levels (RL's) and ground contours as shown have
not been measured by the author of these documents and may
only indicate the approximate general shape of the terrain and
heights of the various building elements. Unless stated other-
wise, actual accurate levels shall be determined either by the
builder or a land surveyor prior to commencement.
6. Written dimensions as show on the drawings take pre-
cedence. DO NOT SCALE DIRECT FROM THE DRAWINGS!. In the
event that questions arise, discrepancies or errors are
noticed, please do not proceed with the work without
requesting further instructions from the builder and/or the
building designer.
7. Construction must not vary from these drawings without
the written approval of the owner/s, licensed certifier and
the building designer.
1
SHEET 07 8, Unless stated otherwise, these drawings have been prep-
ared either for client approval, planning approval or building
permit approval only. No responsibilty will be accepted by
the building designer for drawings or further construction (shop)
drawings prepared by others.
9. Any anchor rods/bolts and roof truss tie-down details
shown are for standard trusses only. The builder shall obtain
tie-down details for any non-standard trusses such as hips,
girders, valleys etc. from the truss manufacturer or struct-
ural engineer. This information shall be made available to
the Local Government or Licensed Certifier at the time of
lodgement of the Building Permit Application.
10. Refer to the structural and/or geochemical engineering
report/s for footings and slab details not shown.
PROPOSED SUB-FLOOR PLAN 11. Unless stated otherwise, rainwater discharge either shall
SCALE 1:100(A3) be directed to the road kerb or dispersed within the prop-
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS erty boundaries to Local Government requirements.
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE.
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT
AUSTRALIAN BUILDING CODE REQUIREMENTS
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
SUB FLOOR PLAN RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-088 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] Mob 0438786080 LOT 402 HAY STREET,
0414801241
www.littledigs.com.au
DESIGN DRAFTING
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] 1:100 (A3) JUN.2021 TEWANTIN, QLD K GOULD 4 OF