Appendix C - House Design Plans
Attached to the e-mail RAL21 0009 - Response to Info Request - House design plans - Gould Email 2 of 2.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn CEILING HEIGHT 2700mm HIGH WITH ALL JOINERY AND DOORS/WINDOWS 2400mm HIGH
LORBOND TRIMDEK
3 DEGREE PITCH CO 900
900 TYP
GFL CH TYP
5600 900 100 SQR HWD POSTS TO DECK AND PORCH
TYP
2700
SELECT DECKING
GFL
FLOOR FRAMING TO ENGINEERS DESIGN
2900
SUBFLOOR CLEARANCE 75x4 SHS POSTS TO SUBFLOOR
TO NCC REQUIREMENTS
Section 1
1 1 : 100
TERMITE PROTECTION
PROVIDE TERMITE PROTECTION IN ACCORDANCE WITH AS 3660.01 - 2000
BOUNDARY
USING LICENSED CONTRACTOR. INSTALL A "PHYSICAL BARRIER" TO
SELECT COLORBOND TRIMDECK ROOF SHEETING PERIMETER OF SLAB & TO ALL PENETRATIONS & PART B SPRAY IN
PREFABRICATED TIMBER ROOF TRUSSES AT 900 CENTERS (TRIMDEK SHEET ROOF) R3.5 INSULATION
TO MANUFACTURERS DESIGN AND SPECIFICATIONS ACCORDANCE WITH AMENDMENT 8 OF BCA.
ATTACHMENTS TO BUILDINGS: ATTACHMENTS TO BUILDING, SUCH AS
DOWNPIPES AND SERVICE PIPES SHALL HAVE A NOMINAL GAP, TO ALLOW
900 900 1510
GFL CH TYP TYP
CLEAR AND UNINTERRUPTED INSPECTION ACROSS THE INSPECTION ZONE.
5600 STRUCTURES SUCH AS STEPS, VERANDAHS, PORCHES, ACCESS RAMPS,
CARPORTS, TRELLISES, DECKS, HOT WATER SYSTEMS, AIR CONDITIONERS,
2425 OR SIMILAR, WHICH ARE NOT PROVIDED WITH ONE OF THE BARRIER
2700
2400
SYSTEMS DESCRIBED IN THE
AS 3660.1-200, SHALL BE SEPARATED FROM THE BUILDING BY A GAP OF AT
LEAST 25mm, TO ALLOW CLEAR AND UNINTERRUPTED VISUAL INSPECTION
GFL ACROSS THE INSPECTION ZONE.
FLOOR FRAMING TO ENGINEERS DESIGN
2900 WHERE ATTACHMENTS OR STRUCTURES, AS OUTLINED ABOVE, ABUT A
BUILDING AND THERE IS NO CLEAR GAP, THEN A BARRIER SHALL BE
PROVIDED TO THE ATTACHMENT, REGARDLESS OF THE SIZE OF THE
75x4 SHS POST TO ATTACHMENT.
SUBFLOOR
SUBFLOOR CLEARANCE
TO NCC REQUIREMENTS BRIDGING AND BREACHING.
Section 2 BARRIERS SHALL NOT BE BRIDGED BY STRUCTURES, FIXTURES OR FITTINGS
2 1 : 100
ATTACHED TO THE MAIN BUILDING ( E.G. HOT-WATER SYSTEMS, STEPS,
VERANDAHS ACCESS RAMPS CLADDINGS, CARPORTS, TRELLISES OR
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND SIMILAR STRUCTURES), NOR SHALL THEY BE BREACHED BY THE
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS INSTALLATION OF SERVICE ENTRY POINTS, DOWN PIPES, AN ADDITIONAL
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE. SLAB, PATHWAYS, LANDSCAPING, GARDENING, OR SIMILAR, UNLESS
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT ADDITIONAL BARRIERS ARE USED TO DETER CONCEALED ACCESS BY
AUSTRALIAN BUILDING CODE REQUIREMENTS
TERMITES TO THE STRUCTURE.
AND RELEVANT AUSTRALIAN STANDARDS.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
SECTIONS RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-088 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] DESIGN DRAFTING Mob 0438786080 LOT 402 HAY STREET,
0414801241
www.littledigs.com.au
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] 1:100 (A3) JUN.2021 TEWANTIN, QLD K GOULD 7 OF