Appendix C - House Design Plans
Attached to the e-mail RAL21 0009 - Response to Info Request - House design plans - Gould Email 2 of 2.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn RAKED CEILING TO
900 STAIRWELL
TYP
PREFABRICATED TIMBER ROOF TRUSSES AT 900 CENTERS (SHEET ROOF)
TO MANUFACTURERS DESIGN AND SPECIFICATIONS
UPPER CH
TBC DURING SETOUT BY BUILDER
8.0m MAX BUILDING HEIGHT
8900 11.5 D
EGRE
E PIT
CH SELECT COLORBOND CUSTOMORB ROOF SHEETING
2700
R3.5 INSULATION
2400
6000
UPPER
FLOOR FRAMING TO ENGINEERS DESIGN
GFL CH
6200
5900
900
TYP
2700
SELECT DECKING
3100
75x SHS POST TO
CONCRETE SLAB TO CARPORT
CARPORT
GFL
CARPORT FLOOR FRAMING TO ENGINEERS DESIGN
3200
2800
CLEARANCE TO TOP OF STAIRS
TBC TO SUIT FINAL RAFTER SIZES
Section 1
1 1 : 100
TERMITE PROTECTION
2100 PROVIDE TERMITE PROTECTION IN ACCORDANCE WITH AS 3660.01 - 2000
USING LICENSED CONTRACTOR. INSTALL A "PHYSICAL BARRIER" TO
PERIMETER OF SLAB & TO ALL PENETRATIONS & PART B SPRAY IN
ACCORDANCE WITH AMENDMENT 8 OF BCA.
GFL CH
ATTACHMENTS TO BUILDINGS: ATTACHMENTS TO BUILDING, SUCH AS
900 900
5900 DOWNPIPES AND SERVICE PIPES SHALL HAVE A NOMINAL GAP, TO ALLOW
TYP TYP CLEAR AND UNINTERRUPTED INSPECTION ACROSS THE INSPECTION ZONE.
2700
STRUCTURES SUCH AS STEPS, VERANDAHS, PORCHES, ACCESS RAMPS,
CARPORTS, TRELLISES, DECKS, HOT WATER SYSTEMS, AIR CONDITIONERS,
OR SIMILAR, WHICH ARE NOT PROVIDED WITH ONE OF THE BARRIER
GFL SYSTEMS DESCRIBED IN THE
FLOOR FRAMING TO ENGINEERS DESIGN AS 3660.1-200, SHALL BE SEPARATED FROM THE BUILDING BY A GAP OF AT
3200 LEAST 25mm, TO ALLOW CLEAR AND UNINTERRUPTED VISUAL INSPECTION
ACROSS THE INSPECTION ZONE.
WHERE ATTACHMENTS OR STRUCTURES, AS OUTLINED ABOVE, ABUT A
BUILDING AND THERE IS NO CLEAR GAP, THEN A BARRIER SHALL BE
75x4 SHS POSTS TO SUBFLOOR PROVIDED TO THE ATTACHMENT, REGARDLESS OF THE SIZE OF THE
Section 2 ATTACHMENT.
2 1 : 100
BRIDGING AND BREACHING.
BARRIERS SHALL NOT BE BRIDGED BY STRUCTURES, FIXTURES OR FITTINGS
ATTACHED TO THE MAIN BUILDING ( E.G. HOT-WATER SYSTEMS, STEPS,
VERANDAHS ACCESS RAMPS CLADDINGS, CARPORTS, TRELLISES OR
CONTRACTOR TO CONFIRM ALL DIMENSIONS AND
LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORKS SIMILAR STRUCTURES), NOR SHALL THEY BE BREACHED BY THE
INCLUDING BOUNDARY OFFSET DISTANCES AND COMPLIANCE. INSTALLATION OF SERVICE ENTRY POINTS, DOWN PIPES, AN ADDITIONAL
ALL CONSTRUCTION TO COMPLY WITH THE RELEVANT SLAB, PATHWAYS, LANDSCAPING, GARDENING, OR SIMILAR, UNLESS
AUSTRALIAN BUILDING CODE REQUIREMENTS ADDITIONAL BARRIERS ARE USED TO DETER CONCEALED ACCESS BY
AND RELEVANT AUSTRALIAN STANDARDS. TERMITES TO THE STRUCTURE.
ISSUE DESCRIPTION GRAHAM GREEN DRAWING TITLE: PROJECT: PROJECT No. REV
DATE DAVID HUGHES PROPOSED THIS DRAWING IS SUBJECT TO COPYRIGHT
A ORIGINAL PRELIMINARY ISSUE 01.06.21 (B.Tech, A.D.C. Eng.,QBCC656975)
14 Aquila Court,
SECTIONS RESIDENCE
AND MUST NOT BE REPRODUCED IN WHOLE
OR IN PART WITHOUR WRITTEN PERMISISON. c 2021 221-087 A
Bli Bli Qld 4561 OWNER/S: SHEET No.:
SCALE: DATE: SITE ADDRESS:
[email protected] DESIGN DRAFTING Mob 0438786080 LOT 401 HAY STREET,
0414801241
www.littledigs.com.au
Gagman Pty Ltd
QBCC No 1261742
Email -
[email protected] 1:100 (A3) JUN.2021 TEWANTIN, QLD B & M GOULD 8 OF